background image

Kelly KLS-N Brushless Motor Controller User

’s Manual 

   

 

V 2.5

 

 

 

24

 

1~250 
Factory set is 15 
 
(6)Brake Rls Time: Brake Release Time, the time of Brake Torque from max to 0, accuracy 0.1s. 
Range: 1~250 
Factory set is 1 
 
(7)BRK_SW Brk %: BRK_SW Braking Percent, the percent of BRK_SW in max braking. Range: 
0~50 
The brake switch regen mode.You have to turn on the brake switch after the throttle is released 
for the regen to occur. 
Factory set is 10 
 
(8)BRK_AD Brk%:It is used to adjust the max regen percentage of brake variable regen mode. 
This regen mode doesn't need brake switch to support any more for KLS controller. 
 
(9)Torque Speed KP: Speed Percent Kp in Torque Mode. Range: 0~10000    Factory set is 3000 
Torque Speed KI: Speed Integral Ki in Torque Mode. Range: 0~500      Factory set is 80 
Speed Err Limit: Speed Error Limit in Torque Mode. Range: 50~4000 Factory set is 1000 
These three parameters are used for PID adjustment. 
If you think the acceleration performance is very very strong,please adjust them to a lower value 
respectively. 
 
(10)Change Dir brake:Value range: Enable and Disable 
It is only useful when you Enable the joystick function. 
If you want to get swift direction changing by using joystick function,you may enable Change Dir 
brake item in user program. 
It will help the motor change the direction of motor quickly after you shift throttle from 0V to 5V,or 
from 5V to 0V. 
Suggestion:factory default is Disable. 
 
(11) 

Compensation Per% 

Tried to increase the current usage during Anti-Slip operation. 
 
(12)IVT BRK MAX and IVT BRK MIN:These two items are only useful when Joystick function is 
enabled in the user program.When you want to use Change Dir Brake to reduce the delay time 
when you shift the direction under joystick operation,there is a RPM limitation to use Change Dir 
Brake function which is only activated when the motor RPM is between IVT BRK MIN and IVT 
BRK MAX. 
Suggestion:factory default is Disable. 
 

(13)Torque Speed Kp:3000  

Torque Speed Ki:80 

Speed Err Limit:1000 

Summary of Contents for KLS6018N

Page 1: ...y KLS N Brushless Motor Controller User s Manual V2 6 Kelly KLS N Brushless Motor Controller User s Manual Devices Supported KLS7212N KLS7215N KLS7218N KLS7222N KLS6018N KLS6030N KLS7230N KLS7245N KLS7250N ...

Page 2: ...Kelly KLS N Brushless Motor Controller User s Manual V 2 6 Rev 2 6 DEC 2019 ...

Page 3: ......

Page 4: ...3 Specifications 5 2 4 Name Regulation 5 Chapter 3 Wiring and Installation 6 3 1 Mounting the Controller 6 3 2 Connections 12 3 3 Installation Check List 16 Chapter 4 Programmable Parameters 17 4 1 Step 1 17 4 2 Step 2 22 4 3 Step 3 23 4 4 How to use Identification angle operation function 25 Chapter 5 Maintenance 29 5 1 Cleaning 29 5 2 Configuration 29 Table 1 Error Codes 30 Contact Us 32 ...

Page 5: ... power MOSFET s and SVPWM and FOC to achieve efficiencies of up to 99 in most cases A powerful microprocessor brings in comprehensive and precise control to the controllers It also allows users to adjust parameters conduct tests and obtain diagnostic information quickly and easily People can program the KLS controller on PC software and Android App There is one more choice for customers to program...

Page 6: ...onnection to 12V Default to throttle switch brake switch reversing switch forward switch and Boost switch 11 3 analog 0 5V inputs that default to throttle input Brake analog input and motor temperature input 12 Copy signal of one of hall sensors 13 Configurable boost switch Enables the maximum output power achievable if the switch is turned on The effect is the same as full throttle position even ...

Page 7: ...gh and low battery voltage 13 Aluminum based PCB board with heat sink plate on the bottom of controller 14 Waterproof connectors for small signal 15 Thermal protection current cut back warning and shutdown on high temperature 16 Controller can do auto_Identification angle for different degrees of hall sensors 17 Configurable high pedal protection the controller will not work if high throttle is de...

Page 8: ...ion of Kelly BLDC motor controllers KLS 72 18N KLS Kelly BLDC motor controller based on sinusoidal waveform which is supposed to work with BLDC motor with three hall sensors All KLS controllers can do regen brake function by default 72 72V batteries N The motor controller included a plastic cover And KLS N is IP66 rating without filling the silica gel by default KLS N used cast aluminum box as bod...

Page 9: ...d contaminants To ensure full rated output power the controller should be fastened to a clean flat metal surface with four screws Applying silicon grease or some other thermal conductive material to contact surface will enhance thermal performance Proper heat sinking and airflow are vital to achieve the full power capability of the controller The case outline and mounting holes dimensions are show...

Page 10: ...Kelly KLS N Brushless Motor Controller User s Manual V 2 6 7 Figure 2 KLS7215N mounting holes dimensions dimensions in millimeters ...

Page 11: ...Kelly KLS N Brushless Motor Controller User s Manual V 2 5 8 Figure 3 KLS6018N KLS7222N mounting holes dimensions dimensions in millimeters ...

Page 12: ...Kelly KLS N Brushless Motor Controller User s Manual V 2 6 9 Figure 4 KLSxx30N mounting holes dimensions dimensions in millimeters ...

Page 13: ...Kelly KLS N Brushless Motor Controller User s Manual V 2 5 10 Figure 5 KLS7245N mounting holes dimensions dimensions in millimeters ...

Page 14: ...Kelly KLS N Brushless Motor Controller User s Manual V 2 6 11 Figure 6 KLS7250N mounting holes dimensions dimensions in millimeters ...

Page 15: ...signal is valid to 12V 2 12V only can be used for LED or switch signals 3 Boost and brake analog regen use the same port on pin2 4 CAN bus is not included in KLS N controller by default When boost is disabled in user program pin2 is used as brake analog regen mode When boost is enable pin2 is used for boost function You may not use two functions at the same time ...

Page 16: ...gnal return Black 1 Temp Motor temperature sensor input Raddle 5 5V 5V supply output 40mA Purple 18 Hall A Hall phase A Yellow 17 Hall B Hall phase B Dark Green 16 Hall C Hall phase C Dark Blue Notes 1 All RTN pins are internally connected 2 Meter function is to copy either of hall sensors 3 Switch to 12V is active Open switch is inactive 4 F N R control and three speed function can not be used at...

Page 17: ...Kelly KLS N Brushless Motor Controller User s Manual V 2 5 14 3 2 2 Standard Wiring of KLS N Controller Figure 8 KLS N controller standard wiring Battery voltage can be used for controller supply ...

Page 18: ...in supplies the second braking function of the controller Figure 7 Wiring of brake switch 12V 12V is provided by external source Figure 8 Wiring of brake switch 12V 12V is provided by KLS N controller on pin11 Figure 9 Wiring diagram for motor temperature sensor NOTE KLS controller can support KTY84 130 150 and KTY83 122 thermistors ...

Page 19: ... connector for communication interface on KLS N controller 3 3 Installation Check List Before operating the vehicle complete the following checkout procedure Use buzzer code as a reference as listed in Table 1 Caution Put the vehicle up on blocks to get the drive wheels off the ground before beginning these tests Do not allow anyone to stand directly in front of or behind the vehicle during the ch...

Page 20: ...ehicle actual working environment so as to be at its best The default parameters of the controller are not recommended for all applications Make sure set the proper parameters before making any test to avoid danger Customers can do program on PC software or Android App The Android Tablet is prefered First of all people need to do Identification angle function for KLS controller before running the ...

Page 21: ... Identification Angle Please download the instruction to how to use Identification angle function from the website www kellycontroller com support php If you can read 85 in Identification Angle item that is to say the system is stable and normal Please fill in 170 for Identification Angle item in user program Then please click Write button in user program Please wait a few seconds before restart t...

Page 22: ... 5 40 Functional description Set throttle effective starting point Suggestion Set according to the practical situation factory default is 20 5V 1 0V 10 TPS Dead High TPS Dead Zone High Range 60 95 Functional description Set throttle effective ending point Suggestion Set according to the practical situation factory default is 80 5V 4 0V 11 Brake sensor type Brake sensor type for brake variable rege...

Page 23: ...th strict quiet control Suggestion Set according to the practical situation factory default is 20KHz Please don t set it 20KHz above Value Range 10KHz or 20KHz 19 Start up H Pedal Value range Enable and Disable Functional description If enabled the controller will detect the current pedal status at power up If throttle got effective output the controller will report fault and not operate Suggestio...

Page 24: ...for function of F N R control Please check the wiring diagram in the manual for F N R control Suggestion Set according to the practical situation factory default is Disable 20 A Three Gears Switch Value range Enable and Disable Functional description If enabled the Forward switch will be activated Please see figure 4 1 Suggestion Set according to the practical situation factory default is Disable ...

Page 25: ...ruise control can not be activated Release throttle and turn the throttle again or turn on the brake switch will make the Cruise control quit Suggestion factory default is Disable 27 Anti Slip If enabled the controller will try to prevent the vehicle rolling back on downhill faster and faster If the ratio of gearbox is high it can try to help the motor stop on the downhill But usually this functio...

Page 26: ...e motor temp is at 110 degrees inside Range 60 170 6 Line Hall Zero It is only useful when the speed sensor is at 4 Useless for KLS N model 4 3 Step 3 1 RLS_TPS Brk RLS TPS Braking Percent the percent of Releasing Pedal BRK in max braking Range 0 50 This is used to adjust the regen current of releasing throttle regen mode type The regen will happen as long as the throttle is released completely Fa...

Page 27: ...or PID adjustment If you think the acceleration performance is very very strong please adjust them to a lower value respectively 10 Change Dir brake Value range Enable and Disable It is only useful when you Enable the joystick function If you want to get swift direction changing by using joystick function you may enable Change Dir brake item in user program It will help the motor change the direct...

Page 28: ...This item is only useful for internal calculation for MCU 246 is about 11 degrees in environment 4 4 How to use Identification angle operation function We must do Identification angle operation before running motor for all KLS controllers The Identification angle operation can be done in PC program or Android App Tablet or Cell Phone KLS N controller is designed for BLDC motor with three hall sens...

Page 29: ... to user program by using an USB to RS232 cable and SM 4A DB9 RS232 Converter Customers also can use a Z TEK USB to RS232 cable and SM 4A DB9 RS232 Converter to connect the controller to an Android Tablet The third option is customers can buy our Bluetooth converter to connect the controller to ...

Page 30: ...item is at 85 But customers still need to run identification angle operation before driving Because the 85 means this controller finished the identification angle operation with the motor in factory before shipment Your motor is different from the motor from controller supplier 5 Please fill 170 in the identification angle item And please click the write button The user program will give a pop up ...

Page 31: ... there are other error codes such as Identify error hall err etc please return to the first picture of user program Please write 85 instead in identification angle by manual If there are no any error codes you can not write it back to 85 by manual Please wait longer time until the error codes occur Please don t keep 170 in the identification angle item when you want to turn off the power supply Ot...

Page 32: ...tions to the bus bars if fitted are tight To avoid physically stressing the bus bars use two well insulated wrenches 5 2 Configuration You can configure the controller with a host computer through either an RS232 or USB port Disconnect motor wiring from controller for configuring existing parameters in the user program or Android APP If this operation is too much extra job for you please make sure...

Page 33: ...user program Table 1 Error Codes Buzzer Error Codes Code Explanation Solution 1 1 Automatic error identification 1 Wrong wiring of motor phase line or hall Please suspend the motor when enable Auto Identify function 1 2 Over voltage error 2 Battery voltage is too high for the controller Check battery volts and configuration 3 Regeneration over voltage Controller will have cut back or stopped regen...

Page 34: ...rrent momentarily high or low battery voltage This can happen during normal operation 3 3 Hall throttle is open or short circuit When the throttle is repaired a restart will clear the fault 3 4 Angle sensor error 1 Speed sensor type error customers may set the correct sensor type through user program or App Please download how to use Identification function instruction from our website 2 Incorrect...

Page 35: ...oller User s Manual V 2 5 32 Contact Us Kelly Controls Home Page http www KellyController com Download user manual instructions and user program www kellycontroller com support php E mail Sales Kelly Controls com Phone 01 224 637 5092 ...

Reviews: