Step 1. Prepare instrument 

To prepare the instrument for mounting, remove the handle, the mounting ears, and both rear feet. The following 

information outlines this process. 

1.  

Remove the handle

 —The handle serves as an adjustable tilt-bail. Adjust its position by gently pulling it 

away from the sides of the instrument case and swinging it up or down. To remove the handle, swing the 

handle below the bottom surface of the case and back until the orientation arrows on the handles line up 

with the orientation arrows on the mounting ears (refer to Figure 1). With the arrows lined up, pull the ends 

of the handle away from the case. 

2.  

Remove mounting ears.

 

•  

Remove the screw that secures each mounting ear.  

•  

Pull down and out to remove each ear. 

  

Figure 1 

Remove handle and mounting ears 

Mounting ear

Screw

Handle

Mounting ear

 

2.  

Remove both rear feet from the instrument

 by pulling out the rubber feet and then removing the screws 

underneath. 

NOTE  

Do not re-install the feet mounting screws. Save all parts removed for future bench top use of 
the instrument. 

 

Summary of Contents for 4299-2

Page 1: ...e parts supplied with the Model 4299 2 Dual Unit Adjustable Heavy Duty Rack Mount Kit 4299 2 part listing Quantity Description Keithley part number 2 2 2 2 1 1 8 1 4 4 4 8 2 2 2 2 2 Hinge Front Rack E...

Page 2: ...low ensures proper cooling Adequate airflow provides air temperatures that are within about one inch of the Model 260x surfaces to remain within specified limits under all operating conditions DO NOT...

Page 3: ...ottom surface of the case and back until the orientation arrows on the handles line up with the orientation arrows on the mounting ears refer to Figure 1 With the arrows lined up pull the ends of the...

Page 4: ...ar Rack Mount Bracket 2602 334 to each instrument on the selected side using two Pan Head Sems Screws 10 32x3 8PPHSEM refer to Figure 2 Figure 2 Attach rear rack mount bracket Pan Head Sems Screw Phil...

Page 5: ...nstall the Rear Bracket 2304 327 securing it and the applicable rear bezels with the 6 32x5 8PPH screws and washers supplied Figure 3 Secure instrument together RA NG E AM PS 350 V PE AK AU TO SH IFT...

Page 6: ...ar rack rails and secure using two Truss Head Screws 10 32x5 8PHTRSH 3 Repeat for other side 4 Install Cage Nuts FA 274 into front rack rail holes aligned with the rear cage nuts refer to Figure 4 Fig...

Page 7: ...ity to the equipment and within easy reach of the operator 1 Slide units into rack by aligning both Rear Rack Mount Brackets 2602 334 with the associated Rack Mount Extension Arms 2602 335 refer to Fi...

Page 8: ...Model 4299 2 Installation Instructions Truss Head Screw Phllips 10 32x5 8PHTRSH 4 Places Front Rack Rail 2 places 8 PA 909 Rev C May 2007...

Reviews: