AIR250 ABDOMINAL
|
OPERATION MANUAL
07
37 inches
(940 mm)
33 inches
(838 mm)
47 inches
(1,194 mm)
115 lbs
(52 kg)
EQUIPMENT SPECIFICATIONS
See Figure 2 for Air250 Abdominal dimensions and weight.
• Resistance Range 0 – 276 lbs (0 – 125 kg)
change resistance in 1 lb/kg increments
• Adjustable Seat
• Maximum user weight limit:
441 lbs (200 kg)
Figure 2. Air250 Abdominal
Equipment Specifications
TECHNICAL DATA
POWER
• 1.5V D Alkaline Batteries (quantity 2, Keiser PN 966500)
• 3V CR2032 Lithium Coin Cell Battery (quantity 1)
Permanently attached, not serviceable. Contact Keiser Customer
Support for service.
AIR STORAGE TANK
The equipment contains an air storage tank (air accumulator) with the following operating parameters:
Maximum working pressure:
125 psi (8.6 bar)
Maximum working temperature: 104ºF (40ºC)
Minimum working temperature:
32ºF (0ºC)
Maximum vessel capacity:
68 in
3
(1.11 L)
TECHNICAL SPECIFICATIONS
Model No.
Device Label (Short Description)
Device Full Description
002721BP
A250 ABDOMINAL-BLK-PWR
Air 250 Abdominal, Black (color), Power (additional display feature)
002721SP
A250 ABDOMINAL-SPC-PWR
Air 250 Abdominal, Special (color), Power (additional display feature)