MAINTENANCE MANUAL
Mirage technical manual
page 16 of 65
Remove body panels
Most parts within the machine that need regular maintenance can be accessed by removing either left
and/or right body panel and/or cup warmer.
Materials needed
Spanner 11, 13 mm
Ring spanner 8 mm
Allen key 2.5 mm, 3 mm
Copper ease
Procedure glass side panels
1. Unscrew the 2 large glass nuts on the side panel by hand (see Figure M 4a).
2. Carefully pull glass side panel away from the machine.
3. Remove the 2 brass mounting nuts (see Figure M 4b) with a 11 mm spanner.
4. Carefully pull plastic side panel away from the machine.
5. When re-mounting the side panels, check the silicone O-ring on the brass mounting nuts for
cracks, replace if necessary. Do not over tighten the brass mounting nuts.
6.
Don’t forget the rubber washer between the glass side panel and the large glass nut, do not over
tighten the large glass nuts.
Figure M 4a (left). To remove glass panel loosen the glass nuts that hold the glass panel.
Figure M 4b (right). Then remove the 2 brass mounting nuts. The inset shows the silicone O-ring on
the mounting nut.
Procedure aluminium side panels (Veloce)
The aluminium side panels do not have a (black) plastic side panel mounted.
1. Unscrew the 2 nuts on the side panel with a 13 mm spanner.
2. Carefully pull aluminium side panel away from the machine, do not lose the rubber and stainless
steel washer underneath the nuts.
3. When remo
unting, don’t forget the rubber and stainless steel washer and do not over tighten the
nuts.
remove glass nuts
remove brass nuts