4
Effective June 2016 -
KEEN PUMP is not responsible for losses, injury or death resulting from a failure to observe these
safety precautions, misuse, abuse or misapplication of pumps or equipment.
PUMP SPECIFICATIONS:
SPECIFICATIONS
WARNING!
THE PUMP MUST BE WIRED BY A QUALIFIED
ELECTRICIAN, USING AN APPROVED STARTER
BOX AND SWITCHING DEVICE.
On 3 phase pumps only, “Motor Protection”
must be provided by the installer. All 3 phase
pumps must be installed with magnetic starters
having 3 leg overload protection in accordance
with the NEC (National Electric Code). For
duplex installations, both pump motors must
have separate overload protection.
Pumps with seal leak detectors must be
connected to the proper control circuitry.
DANGER!
HAZARDOUS MOVING PARTS. To reduce risk of
injury, disconnect power before servicing. Never
put fingers near grinder impeller or in pump inlet
when pump cord is connected or pump is
operating.
For use with maximum 140 degrees F liquid.
DANGER!
In the initial installation, before sewage is
admitted to the basin, there is no danger on
entering the basin. AFTER SEWAGE HAS BEEN
IN THE BASIN, THERE IS DANGER. Sewage
water produces methane and hydrogen sulfide
gasses, both of which are highly poisonous. A
breathing device may be required. Never enter
the basin unless cover is open and outside
blower is used to force fresh air into the basin.
Also the worker in the basin must wear a
harness attached to the surface so he can be
pulled out in case of asphyxiation.
NEVER WORK ALONE!
WARNING!
Do not exceed working load limit of lifting chain,
cable or rope. Do not use lifting chain, cable or
rope where failure could result in loss of life.
Examine all lifting devices, chain, cable or rope
for damage before and after each lift. Do not use
any lifting devices that are not rated for and
designed to lift the weights involved with these
pumps. DO NOT LIFT PUMP BY POWER CORD.
Do not install or remove pump with person(s) in
the basin.
This pump is designed to handle materials
which could cause illness or disease through
direct exposure. Wear and use protective
clothing when working on the pump or piping.
WARNING !
Any wiring to be done on pumps should be
done by a qualified electrician.
NEVER operate a pump with a power cord that
has frayed or brittle insulation.
NEVER let cords or plugs lay in water.
NEVER handle connected power cords with
wet hands.
NEVER be in contact with the liquid being
pumped while pump cord is connected to
electrical supply.
Only qualified personnel should install, operate
or repair pump.
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * * * * * USE AND CARE * * * * * * * * * * * *
DO NOT pump hazardous material not
recommended for pump. NEVER introduce:
Explosives
Flammable Material
Lubricating Oil and/or Grease
Chemicals, Solvents, etc.
Gasoline
Any Petroleum Product
Regulatory agencies advise that the following
items should not be introduced into any sewer:
Glass
Metal
Diapers
Clothing, socks, rags, etc.
Plastic objects (toys, utensils, etc.)
Sanitary napkins or tampons
DO NOT pump without safety devices in place.
For hazardous locations, use pumps listed and
classified for such locations.
DO NOT use non-explosion rated pumps in locations
considered hazardous in accordance with the
National Electric Code, ANSI/NFPA 70-1993.
IMPORTANT!
KEEN PUMP is not responsible for losses, injury or
death resulting from failure to observe these safety
precautions.