  Effective June 2016 - 

KEEN PUMP  is not responsible for losses, injury or death resulting from a failure to observe these 
safety precautions, misuse, abuse or misapplication of pumps or equipment. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PUMP SPECIFICATIONS: 

SPECIFICATIONS 
 

WARNING! 

THE  PUMP  MUST  BE  WIRED  BY  A  QUALIFIED 
ELECTRICIAN, USING AN APPROVED STARTER 
BOX AND SWITCHING DEVICE.  
 
On  3  phase  pumps  only,  “Motor  Protection” 
must  be  provided  by  the  installer.  All  3  phase 
pumps must  be  installed with  magnetic  starters 
having  3  leg  overload  protection  in  accordance 
with  the  NEC  (National  Electric  Code).  For 
duplex  installations,  both  pump  motors  must 
have separate overload protection. 
 
Pumps  with  seal  leak  detectors  must  be 
connected to the proper control circuitry. 
 
DANGER! 
HAZARDOUS MOVING PARTS. To reduce risk of 
injury, disconnect power before servicing. Never 
put fingers near grinder impeller or in pump inlet 
when  pump  cord  is  connected  or  pump  is 
operating. 
 
For use with maximum 140 degrees F liquid.  
 
DANGER! 
In  the  initial  installation,  before  sewage  is 
admitted  to  the  basin,  there  is  no  danger  on 
entering the basin. AFTER SEWAGE HAS BEEN 
IN  THE  BASIN,  THERE  IS  DANGER.  Sewage 
water  produces  methane  and  hydrogen  sulfide 
gasses,  both  of  which  are  highly  poisonous.  A 
breathing  device  may  be  required.  Never  enter 
the  basin  unless  cover  is  open  and  outside 
blower  is  used  to  force  fresh  air  into  the  basin. 
Also  the  worker  in  the  basin  must  wear  a 
harness  attached  to  the  surface  so  he  can  be 
pulled out in case of asphyxiation. 
NEVER WORK ALONE! 
 
WARNING! 
Do not exceed working load limit of lifting chain, 
cable  or  rope.  Do  not  use  lifting  chain,  cable  or 
rope where failure could result in loss of life. 
 
Examine  all  lifting  devices,  chain,  cable  or  rope 
for damage before and after each lift. Do not use 
any  lifting  devices  that  are  not  rated  for  and 
designed  to  lift  the  weights  involved  with  these 
pumps. DO NOT LIFT PUMP BY POWER CORD. 
 
Do not install or remove pump with person(s) in 
the basin. 
 
This  pump  is  designed  to  handle  materials 
which  could  cause  illness  or  disease  through 
direct  exposure.  Wear  and  use  protective 
clothing when working on the pump or piping. 

WARNING ! 
Any wiring to be done on pumps should be 
done by a qualified electrician. 
 
NEVER operate a pump with a power cord that 
has frayed or brittle insulation. 
 
NEVER let cords or plugs lay in water. 
 
NEVER handle connected power cords with 
wet hands. 
 
NEVER be in contact with the liquid being 
pumped while pump cord is connected to 
electrical supply. 
 
Only qualified personnel should install, operate 
or repair pump. 
 
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 
* * * * * * * * * USE AND CARE * * * * * * * * * * * *  
DO NOT pump hazardous material not 
recommended for pump. NEVER introduce: 

 

Explosives 

 

Flammable Material 

 

Lubricating Oil and/or Grease 

 

Chemicals, Solvents, etc. 

 

Gasoline 

 

Any Petroleum Product 

 
Regulatory agencies advise that the following 
items should not be introduced into any sewer: 

 

Glass 

 

Metal 

 

Diapers 

 

Clothing, socks, rags, etc. 

 

Plastic objects (toys, utensils, etc.) 

 

Sanitary napkins or tampons 

 

DO NOT pump without safety devices in place. 
 
For hazardous locations, use pumps listed and 
classified for such locations. 
 
DO NOT use non-explosion rated pumps in locations 
considered hazardous in accordance with the 
National Electric Code, ANSI/NFPA 70-1993. 
 
IMPORTANT! 
KEEN PUMP is not responsible for losses, injury or 
death resulting from failure to observe these safety 
precautions. 

Summary of Contents for K(H)GS2

Page 1: ...PH 419 207 9400 FX 419 207 8031 INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR 2HP SEMI OPEN K H GS2 CENTRIFUGAL SUBMERSIBLE GRINDER SEWAGE PUMPS _____________________________________...

Page 2: ...25 Standard Flow High Head w Radial Cutters INTERNAL CAPACITORS CATALOG NO HP PH VOLTS CORD DISCH KGS2 2001C 2 1 208 10 3 1 25 KGS2 2401C 2 1 240 10 3 1 25 KHGS2 2001C 2 1 208 10 3 1 25 KHGS2 2401C 2...

Page 3: ...ACITORS CATALOG NO HP PH VOLTS CORD DISCH KGSL2 2001C 2 1 208 10 3 1 25 KGSL2 2401C 2 1 240 10 3 1 25 KHGSL2 2001C 2 1 208 10 3 1 25 KHGSL2 2401C 2 1 240 10 3 1 25 Read all instructions in this manual...

Page 4: ...in cable or rope Do not use lifting chain cable or rope where failure could result in loss of life Examine all lifting devices chain cable or rope for damage before and after each lift Do not use any...

Page 5: ...5 Effective June 2016 WIRING DIAGRAMS Internal Capacitors SINGLE PHASE 208 240V 10 3 CABLE WIRES OHM 208V OHM 240V WHITE 1 BLACK 3 1 0 1 6...

Page 6: ...6 Effective June 2016 SINGLE PHASE 208 240V 10 5 CABLE WIRES OHM 208V OHM 240V WHITE 1 BLACK 3 1 0 1 6 WHITE 1 RED 2 6 2 6 8 BLACK 3 RED 2 5 2 5 2...

Page 7: ...7 Effective June 2016 3 PHASE 208 230 460V 14 7 CABLE WIRES 230 VOLT OHM WHITE BLACK WHITE RED BLACK RED WIRES 460 VOLT WHITE BLACK WHITE RED BLACK RED...

Page 8: ...l 56 60 Rockwell C SHAFT 416 Stainless Steel SHAFT SEAL Mechanical Main Motor Secondary Pump Silicon Carbide Rotating Face Silicon Carbide Rotating Face Silicon Carbide Stationary Face Silicon Carbide...

Page 9: ...259 mfd 250 VAC 50 mfd 370 VAC MOTOR THREE PHASE 2 HP 3450 RPM 60 Hz Tri voltage 208 230 460 volts On Winding temperature sensor requires temperature sensor circuitry in control panel Oil Filled Class...

Page 10: ...in basin NEVER WORK ON MOTOR OR GRINDER UNIT WITHOUT DISCONNECTING MOTOR LEAD WIRES FROM CONTROL PANEL DO NOT RELY UPON OPENING THE CIRCUIT BREAKER ONLY ELECTRICAL MOTOR OVERLOAD PROTECTION Single pha...

Page 11: ...Check valve stuck closed or installed backwards Pump motor damaged worn Pump may be air locked Cutter loose or jammed on shaft worn or damaged Pump is noisy Grinder impeller may be rubbing against gr...

Page 12: ...he impeller cutting bar and remove the allen head cap screw from the end of the shaft 2 Use a large screwdriver in the slot end of the shaft and tap counterclockwise on one of the large cutter vanes w...

Page 13: ...factory STANDARD TOOLS REQUIRED Standard socket wrench set Ball peen Hammer Feeler Gauges minimum range 008 012 inches Vise grip pliers Allen head socket set Screwdrivers Wire brush CAUTION Disconnect...

Page 14: ...go to step 13 If tolerance is beyond or under range go back to step 7 13 Place new or cleaned slicer retainer onto volute bottom 14 Make sure the impeller turns freely by hand after reassembly Some dr...

Page 15: ...15 Effective June 2016...

Page 16: ...16 Effective June 2016 REPAIR PARTS LIST...

Page 17: ...17 Effective June 2016...

Page 18: ...0317 1 02 3 K0317 1 02 19 Screw Skt Hd Allen 1 4 20UNC x 3 4 LG SST 1 SCS1 4X3 4SS 1 SCS1 4X3 4SS 20 Washer Impeller KGS series 1 K0451 1 01 1 K0451 1 01 22 Shim 5 8 ID x 1 00 OD x 005 SST 2 K0458 1 0...

Page 19: ...6X1 1 4SS 4 CS5 16X1 1 4SS 15 Screw Cap 5 16 18UNC x 1 1 2 LG SST 4 CS5 16X1 1 2SS 4 CS5 16X1 1 2SS 16 Screw Cap 10 32UNC x 5 8 LG SST 1 CS10X5 8SS 1 CS10X5 8SS 17 Screw RD Head Drive 4 7UNC x 1 4 LG...

Page 20: ...re Moisture Detector w resistor 1 K0138 1 01 1 K0138 1 01 35 Resistor 330k ohm 1 K0381 1 01 1 K0381 1 01 35 Sensor Moisture 1 KG2160 1 KG2160 36 Capacitor Start 216 259 Mfd 250 VAC 1 K0408 1 02 37 Cap...

Page 21: ...ng a phase converter or if 3 phase power is supplied by only two transformers making an open Delta system WARRANTY EXCLUSIONS Keen Pump specifically disclaims the implied warranties of merchantability...