P30
Update via USB
Firmware Update Instructions V1.02
13
© KEBA
4) After the update has been installed, the status LED is permanently
green.
5) Disconnect the USB stick from the charging station. This triggers a
restart of the charging station.
6) Check the firmware version of the charging station, see
4.3
Mount covers
In order to operate the charging station correctly, all covers must be inserted
and screwed tight. Proceed as follows:
1) Insert connection panel cover
1
and tighten with 4
screws with 2 Nm. The tabs on the connection panel cover
must be flush with the enclosing housing. Only then will the
device be properly sealed.
2) Hook in the housing cover at the top
1
and close it at the
bottom
2
. The housing cover must glide into the guides
without considerable resistance. The housing cover must
be correctly seated in the housing guide on all sides.