P30
Writeable Data
Modbus TCP Programmers Guide V1.02
17
© KEBA
Information
The charging process must be stopped beforehand!
Index
Name
Type
Attr.
5012
Unlock
UINT16
wo
Supported values:
●
0: unlock plug
4.4
5014 - Enable/Disable charging station
In this register, the charging station can be enabled or disabled. An active
charging process will be stopped.
Index
Name
Type
Attr.
5014
Enable user
UINT16
wo
Supported values:
●
0: Disable charging station
●
1: Enable charging station