P30
Readable Data
Modbus TCP Programmers Guide V1.02
12
© KEBA
Type and
features
Product
type
Cable /
Socket
Sup-
ported
current
Device
series
Energy
meter
Autho-
rization
No RFID
0
With RFID
1
1)
MID (Measuring Instruments Directive): Measuring Instruments Directive
Example:
Value 304111:
The charging station has the following type and features:
●
KC-P30
●
32 A
●
c-series
●
standard energy meter, not calibrated
●
with RFID
3.9
1018 - Firmware version
Note: In P30 Modbus TCP version 1.11, this register's number is 1013.
This register contains the firmware version of the charging station. The rep-
resented value is in decimal and has to be converted to hex in order to read
the firmware version.
Index
Name
Type
Attr.
1018
Firmware
UINT32
ro
Example:
Value 50990336 converted to hex = 30A0D00, which means firmware ver-
sion 3.10.14 (0A=10, 0D=14).
3.10
1020 - Active power
This register contains the active power in milliwatts.
Unit: mW
Index
Name
Type
Attr.
1020
Active Power
UINT32
ro
Example:
Value 98661: The active power of the charging station is 98661 mW =
98.661 W.