M20
Configuration
V1.02
34
© KEBA 2022
7.2.3
Adapt configuration file
To adapt the configuration file, the USB stick must be plugged into a PC and
the
CFG
directory on the USB stick must be opened.
To use the configuration file to configure other masters, the filename and
parts of the content must be adapted.
Adapting the filename
The filename contains the serial number of the KeContact M20 from which
the configuration was read out. This serial number must be deleted from the
filename.
A configuration file without a serial number in the filename can be used for
the configuration of multiple KeContact M20.
Adapting the content
The specific configurations that only apply to one KeContact M20 must be
adapted or deleted in the configuration file.
The individual sections are marked with
[Name]
. Values are assigned to the
variables according to the following formula:
Variable = Value
To adapt and delete the specific configurations, proceed as follows:
1) Open the configuration file with a text editor.
2) Change
AmountConnectors=[x]
. The number of available charging sta-
tions in the charging network must be entered as the value.
3) Delete the following entries:
ChargeBoxIdentity
,
Connect2Connec-
torSerial
,
HOTSPOT_SSID
and
HOTSPOT_KEY
.
4) Save the file and close.
The configuration file is adapted.
Information
By deleting all
Connect2ConnectorSerial
entries, the KeContact M20 au-
tomatically searches for other charging stations in the charging network.
The number of charging stations specified under
AmountConnectors
is the
number searched for.
7.2.4
Import configuration
To import the configuration to the desired KeContact M20, proceed as fol-
lows:
1) Plug the USB stick into the KeContact M20. It must be ready for opera-
tion and already configured.
2) Transfer of the configuration is started automatically. The status LED
also flashes and soft audible signals are emitted at longer intervals.