M20
Mounting and installation instructions
V1.02
25
© KEBA 2022
7) If necessary, establish protective grounding for the mounting package.
The KeContact M20 is installed on the top hat rail.
5.6
Wall installation
The KeContact M20 can optionally be installed on a wall. Wall brackets are
needed to do this. These are not included in the scope of delivery and can
be ordered as accessories.
Information
The SIM card may need to be installed before the mounting is done. Other-
wise, installation is no longer possible.
Required materials and tools:
●
4 x M3 screws, 10 mm length (included in the scope of delivery)
●
Phillips screwdriver PH1 (not included in the scope of delivery)
●
Wall brackets (not included in the scope of delivery)
The four screw holes are located on the underside of the KeContact M20.
To install the KeContact M20 on the wall, proceed as follows:
1) Unscrew the M3 screws on the underside of the housing.
2) Secure the two wall brackets (
1
) on the KeContact M20 with four M3
screws.