M20
Configuration
V1.02
33
© KEBA 2022
In addition, the settings that allow the configuration to be read out and im-
ported must be activated in the web interface (under "Configuration" - "De-
vice"):
●
"
Allow USB init
": Allows the configuration to be read out. This setting
must be activated at the master, which provides the configuration.
●
„
Allow USB config
": Allows the import of the configuration. This setting
must be activated at the master to which the configuration is transferred.
To transfer the configuration to a different master, the following steps are
necessary:
●
Creating a configuration
●
Reading out configuration
●
Adapting the configuration file
●
Importing configuration
7.2.1
Create configuration
If this has not yet been done, a first KeContact M20 must be configured with
the desired settings. These settings serve as the basis for the configuration
of additional KeContact M20.
The easiest way to configure the KeContact M20 is via the web interface. On
the graphical user interface the available settings and selection fields are
provided with short explanations.
Information
Not all settings available in the web interface can be transferred via USB
stick to additional KeContact M20.
7.2.2
Read out configuration
To read out the configuration, proceed as follows:
1) Plug the USB stick into the KeContact M20. It must be ready for opera-
tion and already configured.
2) Transfer of the configuration is started automatically. The status LED
also flashes and soft audible signals are emitted at longer intervals.
Information
Do not remove the USB stick during the writing process! Otherwise it can-
not be used for another configuration.
3) After the transfer is finished (approx. 1-2 minutes), the status LED goes
out and an audible signal sounds.
4) Remove the USB stick.
The configuration has been read out and transferred to the USB stick.