KEB COMBIBOX Instruction Manual Download Page 4

  

  

  
  

 

PERMISSIBLE SHAFT LOAD

The value F

N

 refers to the load at the middle of the shaft, distance L/2.  It 

is based on a sercive, life of 10,000 h and a speed of 1500 rpm.  For other 

speed and service life values, F

can be calculated with the aid of the graph 

shown above.  If additional axial forces occur, a recalculation of the bearing 

load should be performed by the factory.

 Example:

  L

h

 = 5000 h, n = 1000rpm

  F/F

N

 = 1.5 therefore F = 1.5 x F

N

OPERATION & MAINTENANCE

The KEB Combibox is shipped ready for installation with the air gap 

preadjusted to the nominal value.  NEMA, or IEC mounting dimensions on 

the input and output ends allow for easy assembly to motors and gearboxes.  

DO NOT FORCE FIT

 when mounting.  An antiseize lubricant should be used 

on the shaft when mounting the Combibox.  To avoid contamination of the 

friction surfaces, do not use excessive amounts of lubricant.

Proper sizing of the Combibox in accordance with the application will 

minimize wear and reduce maintenance.  The air gap should be readjusted 

according to the instructions when it reaches three times its nominal 

4

Combibox Instruction Manual

Reviews: