background image

CLEANING

Proper care should be taken to fully clean the griddle on a regular basis..

DISCONNECT ELECTRIC POWER SOURCE BEFORE CLEANING.

CONTROL PANEL - Clean any grease build-up on the thermostat knobs.

NOTE:

If grease gets into the body of the thermostat, it may cause it to fail.

IF GREASE GETS INTO THE BODY OF THE THERMOSTAT, 
IT MAY CAUSE POSSIBLE ELECTRICAL SHOCK.

V SERVICE DIAGNOSIS

A.

Trouble-Shooting

The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you
use a qualified service company. 

PROBLEM

PROBABLE CAUSE

SOLUTION

Griddle won’t heat.

a. No electricity to griddle.

a. Connect griddle to an approved source of  

power.

b. Thermostat isn’t on.

b. Turn thermostat to desired cooking

temperature.

c. Thermostat is faulty.

c. Replace thermostat.

d. Connections are loose.

d. Tighten connections.

e. Element is faulty.

e. Replace element.

Temperature of griddle

a. Thermostat out of calibration.

a. Calibrate thermostat. 

is erratic.

See page 4–Calibration.

b. Thermostat bulb improperly 

b. Adjust thermostat bulb.

placed.

c. Exhaust problems or drafts.

c. Contact your HVAC representative.

Griddle is overheating.

a. Thermostat out of calibration.

a. Calibrate thermostat.

b. Thermostat is faulty.

b. Replace thermostat.

5

Summary of Contents for Teppanyaki Griddle

Page 1: ...AND OPERATING PLATES 6 TEPPANYAKI ELECTRIC GRIDDLE CONTROL PANEL 6 HEATING ELEMENT ASSEMBLY 7 SECTION VII WIRING DIAGRAMS TEPPANYAKI GRIDDLE 7 CONTENTS IMPORTANT Keep a copy of your bill of sale The d...

Page 2: ...e specifications at any time B WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THESE INSTALLATION OPERATING AND MAINTENANCE IN...

Page 3: ...ce for future reference The installation of your new griddle must conform to local codes Your ventilation hood when installed must conform to the current standard Installation clearance requires 6 152...

Page 4: ...The Teppanyaki Griddle is equipped with a three wire terminal block with ground for field wiring Compare the griddle terminal connections with the wiring diagram on page 7 This unit is designed to be...

Page 5: ...nt of elements under Teppanyaki Griddle plate 4 After each load scrape the griddle surface completely clean using the 4 102mm wide replaceable blade scraper DO NOT HACK CHOP HIT OR CUT ON THE TEPPANYA...

Page 6: ...icing will lead to years of quality performance CALIBRATION Tools Accurate surface thermometer Standard screwdriver 1 Turn on the griddle with thermostat set at 300 F 149 C Allow elements to cycle on...

Page 7: ...qualified service company PROBLEM PROBABLE CAUSE SOLUTION Griddle won t heat a No electricity to griddle a Connect griddle to an approved source of power b Thermostat isn t on b Turn thermostat to de...

Page 8: ...G or your service company You may also order online at Keating s part store www keatingofchicago com The model serial plate is located on the control panel assembly The serial and model numbers are ne...

Page 9: ...3 INSULATION BOARD 24 610mm 002489 4 HEATING ELEMENT PAN 24 610mm 020553 5 HEATING ELEMENT BULB HOLD DOWN M BRACKET 008593 6 HEATING ELEMENT HOLD DOWN BRACKET 029352 7 3 8 9 525mm NUT WASHER LOCK WASH...

Page 10: ...08 10...

Page 11: ..._______________________________________________ ADDRESS __________________________________________________________________________________________________________________ CITY ________________________...

Reviews: