keatingofchicago.com
10
STEP 2
PRESS all 3 buttons in sequence: left-center-right.
The BEEPER will BEEP when each button is pressed.
If BEEPER does not BEEP, the timer is defective. STOP
TESTING. Reset procedure is completed when 1:00
appears on the digital display.
OPTIONAL TIMER
Operating Instructions (Part # 056921)
DIGITAL TIMERS
The electronic timers, standard on TS & IFM models,
provide a clearly visible and accurate display and are
very easy to use.
PROGRAMMING
To program the timers, the unit must be in the idle
mode. Press and hold the set button for approximately
two seconds. The display will show “SEt”. Press the
T1, T2 or T3 for the cook time to be programmed. The
display will show the current setting for that cook time.
Use the up or down button to increment or decre-
ment the setting. When the setting is correct, press
and hold the set button again for approximately two
seconds. The display will show "StO" for approximately
two seconds and the timer will return to normal opera-
tion. Repeat the process as necessary for the other
timers.
OPERATING LOGIC
When the timer is powered up, the display will show
the time setting for the cook time that was operated
last and the relay output contacts will be open. To
start a cycle, press the desired cook time button (T1,
T2 or T3). The display will begin to countdown from
the preset time setting and the relay output contacts
will close. During the countdown the colon will fl ash at
a one-second rate. When the countdown has reached
"00:00" the relay output contacts will open, the
display will fl ash, and the audible alarm will sound. To
cancel the audible alarm, press any button.
PAUSE FEATURE
To pause a cycle in progress, press any button. The
relay output contacts will open, the display will fl ash,
and the countdown will pause. To resume the count-
down, press any button. The display will resume the nor-
mal countdown and the relay output contacts will close.
CANCELING A CYCLE
To cancel a cycle in progress press and hold any but-
ton for approximately two seconds. The relay output
contacts will open and the display will show the time
setting for the cook time last used.
MAINTENANCE
WARRANTY REPAIRS
Keating’s warranty begins with the date of installa-
tion. In the event that your Instant Recovery® Gas
Fryer, under warranty, needs repairs other than routine
maintenance or cleaning, you are required to contact
Keating of Chicago (at 1-800-KEATING) before calling a
local service company.
PREVENTIVE MAINTENANCE
Preventive maintenance should be done in daily, week-
ly, monthly and yearly intervals as necessary. Following
preventive maintenance procedures will help keep your
fryer working effi ciently. Proper care and servicing will
lead to years of quality performance.
PREVENTATIVE MAINTENANCE CHART
TIME FRAME
OPERATOR/OWNER
AT LEAST
DAILY*
• Check lights and controls.
• Check that the oil is up to
“Fill Level” line.
• Clean all baskets.
• Drain, strain or fi lter oil.
AT LEAST
WEEKLY*
• Drain and clean fryer.
• Boil-out fryer.
AT LEAST
MONTHLY*
• Verify Thermostat settings.
• Test Hi-Limit control.
TIME FRAME
QUALIFIED SERVICE PERSONNEL
AT LEAST
YEARLY*
• Disassemble fryer to clean pilot
and burners orifi ces and runner
pilot tube.
• Check and replace radiants.
• Calibrate thermostat.
*
High production facilities should be checked more often.
Contact the factory or a local service company to perform
maintenance and repairs.