background image

C

CA

AU

UT

TIIO

ON

N

A KEATING FRYER OR FILTER SHOULD BE DRAINED
ONLY UNDER THE SUPERVISION OF PROPERLY
TRAINED PERSONNEL. WHEN DISCARDING OIL, A
COVERED RECEPTACLE APPROVED FOR USE WITH
HOT OIL SHOULD BE USED. USE OF A NON-
APPROVED RECEPTACLE OR METHOD OF DRAINING
THE OIL COULD JEOPARDIZE THE SAFETY OF THE
OPERATOR.

3. Remove oil container to a secure area to prevent

accidental spillage.

4. Fill fryer vessel to "Fill Level" line with water.

5. Set thermostat and turn fryer on to bring water to a

gentle boil. Once boil has been reached, turn fryer
off.

C

CA

AU

UT

TIIO

ON

N

UNDER NO CIRCUMSTANCES SHOULD THE
FRYER AND FILTER BE LEFT UNATTENDED DUR-
ING BOIL-OUT. TRAINED PERSONNEL MUST BE
PRESENT DURING THE PROCEDURE TO PRE-
VENT BOIL OVER OR TO TURN OFF THE POWER
IF WATER DROPS BELOW HEATING TRANSFER
TUBES.

6. Dissolve 2/3 cup of Keating Sea Powder for every

five gallons of water and let soak for 1/2 hour. If
there is a large build-up of carbonized grease,
allow for fryer to soak overnight.

7. While soaking, a natural fiber brush may be used

to scrub the tubes and inside walls of fryer. Drain
the water and Sea Powder into a dry suitable
receptacle and remove from cooking area. Sprinkle
Keating Klenzer liberally on tubes and sides of
fryer vessel. A non-abrasive scouring pad amy be
used to remove the now softened carbonized
grease. Thoroughly rinse fryer vessel with potable
water to remove all Klenzer. Prior to refilling with
oil, wipe the inside of the fryer vessel making sure
all water and Klenzer have been removed.

NOTE:

Do not pump water through the filter system.

DO NOT DAMAGE OR REPOSITION THERMOSTAT
PROBE AS THIS MAY AFFECT THE ACCURACY OF
THE FRYER.

C

CA

AU

UT

TIIO

ON

N

DO NOT MIX WATER AND HOT OIL

8. Close the drain valve.

9. Check thermostat bulb positioning.

10. Refill the fryer with new or filtered oil.

TO AVOID DAMAGING THE FRYER, DO NOT
POWER WASH, SPRAY OR HOSE IT DOWN WHILE
CLEANING IT.

CLEANING AND BOIL-OUT FOR A FRYER WITH

ATTACHED FILTER SYSTEM

When cleaning and boiling out your fryer use Keating
Sea Powder and Keating Klenzer to keep your fryer in
top condition.

C

CA

AU

UT

TIIO

ON

N

A KEATING FRYER OR FILTER SHOULD BE
DRAINED ONLY UNDER THE SUPERVISION OF
PROPERLY TRAINED PERSONNEL. WHEN DIS-
CARDING OIL, A

COVERED RECEPTACLE

APPROVED FOR USE WITH HOT OIL SHOULD BE
USED. USE OF A NON-APPROVED RECEPTACLE
OR METHOD OF DRAINING THE OIL COULD JEOP-
ARDIZE THE SAFETY OF THE OPERATOR.

1. Operator should be outfitted with proper attire

including: 

–Oil and heat resistant gloves
–Oil and heat resistant apron
–Safety goggles
–Oil and heat resistant footwear

2. Turn the fryer off.

A cleaning hose and wand have been provided for
discarding oil.

3. Attach cleaning hose to quick disconnect located

on the bottom right side of your filter.

4. Remove baskets and screen. Drain fryer into the

central filter drawer.

7

SAFE & EASY FILTER

(SIDE VIEW)

Connect hose here to discard oil

Summary of Contents for NSTANT RECOVERY AA2000

Page 1: ...ioning 1 Ventilation 1 National Code Requirement 1 Gas Connectors Pipe Size 2 Flexible Gas Connection Quick Disconnect Devices 2 Restraining Devices 2 Electrical Connection 2 Leveling 3 PLACING YOUR K...

Page 2: ...l gas supplier THE EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE BASIC PLUMBING CODE OF THE BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL INC BOCA AND THE FOOD SER VICE SANITATION MANUAL...

Page 3: ...will be supplied by the car rier DO NOT RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE FIRST STEPS POSITIONING Keep appliance area free and clear of any com bustibles Position the Kea...

Page 4: ...age to the gas valve The required gas pressure for proper operation of each fryer is 4 water col umn for natural gas and 10 water col umn for propane gas at the burner manifold If more than one gas un...

Page 5: ...ers on ALWAYS disconnect fuel source and power supply before servicing NEVER move a fryer when full of oil NEVER introduce objects or liquids into fryer while operational which are not designed or mad...

Page 6: ...will come on HIGH LIMIT TEST PROCEDURE All Models DO BI MONTHLY STEP 1 Place a suitable thermometer in the oil on the front left corner of the fryer 2 from the top to check temperature STEP 2 Set the...

Page 7: ...WER switch to ON posi tion Its green light and the timers will come on STEP 3 Light constant pilot located on left side of pilot runner tube STEP 4 Hold the PUSH TO LIGHT switch for 30 seconds The pil...

Page 8: ...realize substantial savings in oil costs as well as maintenance charges We have listed some of the conditions which are catalysts in the breakdown of oil 1 Contact with Oxygen 2 Carbonization of Crum...

Page 9: ...ly rinse fryer vessel with potable water to remove all Klenzer Prior to refilling with oil wipe the inside of the fryer vessel making sure all water and Klenzer have been removed NOTE Do not pump wate...

Page 10: ...ssel making sure all water and Klenzer have been removed DO NOT DAMAGE OR REPOSITION THERMOSTAT PROBE AS THIS MAY AFFECT THE ACCURACY OF THE FRYER C CA AU UT TI IO ON N DO NOT MIX WATER AND HOT OIL 12...

Page 11: ...THERMOSTATS These operational problems can easily be correct ed by thermostat bulb positioning Keating s patented thermostat application is accu rate within 2 F of the dial setting between 250 F 350 F...

Page 12: ...r fryer 10x11 18 up The end of thermostat bulb should touch the burner tube for 14 fryers 6 Replace burners 7 Replace control panel back 8 Slide back fabric shield over capillary and care fully coil c...

Page 13: ...lon will flash at a one second rate When the countdown has reached 00 00 the relay output contacts will open the display will flash and the audible alarm will sound To can cel the audible alarm press...

Page 14: ...7406 G 1 SWITCH ROCKER WHITE MOMENTARY PUSH TO LIGHT 032297 H 1 INDICATING LIGHT AMBER 021254 J 1 SWITCH ROCKER WHITE LIGHT REPLACEMENT KIT 058328 K 1 SWITCH ROCKER WHITE MOMENTARY HIGH LIMIT TEST 032...

Page 15: ...Drain Shown QTY DESCRIPTION P N A 3 3 FIN RADIANT 000041 B 1 POT 14 GAS WELDMENT Call 800 KEATING C 3 BURNER 028048 D 1 DRAIN VALVE 004553 1 REAR DRAIN VALVE NOT SHOWN 016341 E 1 RUNNER PILOT ASSEMBLY...

Page 16: ...LP 023624 POT ASSEMBLY 20BB 20TS GAS Front Drain Shown QTY DESCRIPTION P N A 4 3 FIN RADIANT 000041 B 1 POT 20 GAS WELDMENT Call 800 KEATING C 4 BURNER 028048 D 1 DRAIN VALVE 004554 1 DRAIN VALVE 2 FR...

Page 17: ...15 AA2000 ELECTRICAL ASSEMBLY BB2000 ELECTRICAL ASSEMBLY...

Page 18: ...16 Electrical Assembly not shown to scale TS2000 ELECTRICAL ASSEMBLY Electrical Assembly not shown to scale BB ELECTRICAL ASSEMBLY WITH SE FILTER...

Page 19: ...17 TS ELECTRICAL ASSEMBLY WITH SE FILTER BASKET LIFT ELECTRICAL ASSEMBLY ALL FRYERS...

Page 20: ...Stir oil repeatedly with a paddle until water boils off Filter oil If necessary allow oil to cool Drain about one quart of it to remove remaining water Basket lift mechanism a Connections are loose or...

Page 21: ......

Page 22: ..._______________________________________________________________ INVOICE NUMBER ____________________ SERIAL NUMBER ________________________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS _________...

Reviews: