11
COMMON PROBLEMS
SOLUTIONS (FOLLOW IN SEQUENCE)
Water always filling
1. Clean sensors thoroughly with brush and vinegar.
2. Adjust the sensitivity of the B Board (for the top sensor) fully clockwise.
3. If filling persists, ground out the top sensor (if filling stops, replace sensor –
Part #010212).
4. If filling persists after grounding the sensor, replace the B Board (Part
#001166).
Water never fills
1. Turn water switch (far right) ‘on.’
2. Clean sensors thoroughly with the brush and vinegar.
3. Adjust the sensitivity of the B Board (for the top sensor) fully counter
clockwise (follow sevice instruction sheet -
Setting Water Level Control
).
4. Remove the wire from the top sensor. If filling begins, replace sensor (Part #
010212).
5. If water does not fill, place a jumper wire across terminals A & C on the B
Board. If filling begins, replace B Board (Part # 001166).
6. If water does not fill, replace water solenoid (Part # 008133).
Timers counting down in the
wrong mode (not minutes or
seconds)
1. Reset the timer (see pages 8-9).
Water leaking in the rear of
the pasta cooker
1. Replace fill hose (Part #037390 – sold per foot)
Breakers continue to trip
1. Ensure all wires to the contactors, breakers and elements are tight.
2. Verify water is not getting on any components.
3. Check contactors for proper operation.
4. Check continuity of heating elements.
5. Replace breaker.
Heating elements won’t
come on
1. Verify operating instructions in the manual.
2. Clean sensors with brush and vinegar.
3. Adjust sensitivity of the A Board (for the lower sensor) fully clockwise (follow
service instruction sheet -
Setting Water Level Control
).
4. Place the wire attached to the lower sensor to the ground (if heating begins,
replace sensor – Part #010212).
5. If heating does not being, place a jumper wire across terminals A&C on the A
Board. If heating begins, replace the A Board (Part #001167).
TROUBLESHOOTING CHART
The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that
you use a qualified service company. Call 1-800-KEATING if you need assistance in locating a qualified service
company.
Summary of Contents for INSTANT RECOVERY SERIES 2009
Page 17: ...15 VII WIRING DIAGRAMS 14 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS 2...
Page 18: ...14 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM 16...
Page 20: ...18 14 ELECTRIC PASTA WITH BASKET LIFT AND DIGITAL TIMERS WIRING DIAGRAM...
Page 22: ...20 18 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...
Page 23: ...21 24 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM...
Page 24: ......