pages 11 - 12 Wiring Diagram) to see if the griddle is
connected three phase or single phase. All wires,
cords, plugs, receptacles and circuit breakers must be
sized adequately for the full load rating of the griddle as
specified by local codes or, in the absence of local
codes, by the current National Electrical Code
ANSI/NFPA 70 or the Canadian Electrical Code CAN
22.2 as applicable.

The Electric MIRACLEAN

®

Griddle is also equipped

with a grounding lug next to the terminal block. For
proper grounding procedures, see local codes or, in the
absence of local codes, the current National Electrical
Code ANSI/NFPA 70 or the Canadian Electrical Code
CAN 22.2 as applicable.

NOTE: 

The connections to the griddle can be changed

in the field from three phase to single phase or from
single phase to three phase. This can be done by
simply changing the wiring at the terminal block. To
change the connections for your griddle, see the wiring
diagram for your griddle on pages 11 - 12.

NOTE: 

For griddles rated at 208-240 volts, the

amperage ratings marked on the nameplates of the
griddles are listed at 240 volts as required by UL. If
your griddle uses a 208 or 220 volt system, refer to the
Electric Griddle Specifications on pages 14 to 16 to
determine the full load rating of the griddle.

NOTE: 

A hole has been punched in the rear of the

griddle cabinet for a cord or conduit exit. If a cord is
used, the National Electrical Code, UL standards and
most local codes require a bushing or strain relief (not
provided by Keating) to protect the cord.

WIRE SIZE

Use the table below to help determine the proper wire
size for electrical service hook-up. Use the largest amp
value of the three conductors for 3-phase installations
when using the table. The amperage values for a
product can be found on its serial number tag. Consult
the National Electrical Code Handbook for additional
information or to help answer questions about wire size
selection.

*For runs greater than 75' up to 125', use the next wire
size larger to keep the voltage drop to less than 3%.
For runs greater than 125', consult the National
Electrical Code Handbook to help determine the proper
wire size.

**2/0 wire ambient temperature must be kept at less
than 104°F (40°C).

III OPERATING

CONDITIONING THE
GRIDDLE 

The MIRACLEAN

®

Griddle plate has been “seasoned”

at the factory. The chrome surface when heated
creates a thin layer of chrome oxide which acts as a
releasing agent for food products. If you feel you need
to recondition the surface, the following instructions
should be followed:

1.  Follow cleaning instructions on page 5.

2.  Heat the MIRACLEAN

®

to 400°F for one hour.

3. Lower thermostat to 350°F, allowing the

MIRACLEAN

®

to cool to about 350°F, as is evident

when griddle cycles on or surface thermometer
indicates correct temperature.

4.  Lightly coat the MIRACLEAN

®

surface with griddle

oil.

NOTE: 

Despite the food releasing properties, the

chrome surface is not a true “non-stick” surface. For
best cooking results and product appearance, use
griddle oil for products that require the surface to be
conditioned.

COOKING

Keating MIRACLEAN

®

Griddles are designed to

provide maximum production efficiency and deliver
high quality food products. Follow cooking procedures
below.

1.  For 208-240 Volt Unit: Set ON/OFF switch to “ON”

position. The Power indicating light will illuminate.

For 480 Volt Unit: Rotate thermostat knob from
“OFF” position to desired temperature. The power
indicating light will illuminate.

2.  Set the thermostat to the desired temperature and

wait approximately ten minutes for  preheating.
Recommended cooking temperatures for various
food products are as follows:

Conductor

Current (Amps up to)

Recommended

wire size (AWG)

15

14*

20

12*

30

10*

40

8

55

6

70

4

95

2

125

0

145

2/0

165

2/0**

190

2/0**

Summary of Contents for Griddle

Page 1: ...LY 9 STAND ASSEMBLY 10 WIRING DIAGRAMS 11 14 24 DEEP MODELS 15 30 DEEP MODELS 16 36 DEEP MODELS 17 CONTENTS IMPORTANT Keep a copy of your bill of sale The date on the bill establishes the warranty per...

Page 2: ...E VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OP...

Page 3: ...Electrical Code CAN 22 2 as applicable Your ventilation hood when installed must conform to the current ANSI NFPA 96 standard Installation clearance requires 6 from rear and side walls You must mainta...

Page 4: ...the current ANSI NFPA 96 standard ALL connections and placement must comply with local and national codes It is the responsibility of the owner and local installer to comply with these regulations whe...

Page 5: ...be found on its serial number tag Consult the National Electrical Code Handbook for additional information or to help answer questions about wire size selection For runs greater than 75 up to 125 use...

Page 6: ...ement of elements under MIRACLEAN plate 5 After each load scrape the griddle surface completely clean using the 4 wide replaceable blade scraper NOTE DO NOT HACK CHOP HIT OR CUT ON THE MIRACLEAN SURFA...

Page 7: ...40 Volt Unit Turn each thermostat fully counterclockwise and On Off switch to OFF position For 480 Volt Unit Turn thermostat knob to OFF position IV MAINTENANCE WARRANTY REPAIRS Keating s warranty beg...

Page 8: ...position Place thermometer on plate over bulb half way toward rear of griddle Figure 4 1 Thermostat calibration 4 If calibration of griddle is found to be less than 50 F off simply loosen four dial p...

Page 9: ...wer b Reset circuit breakers External c Set On Off switch to ON position d Turn thermostat to desired cooking temperature e Replace On Off switch f Replace thermostat g Tighten connections h Replace e...

Page 10: ...rmostat 400 F 029521 Thermostat 550 F 034870 Thermostat Dial Plate 400 F 060105 Thermostat Dial Plate 550 F 004163 Thermostat Knob 400 F 038267 Thermostat Knob 550 F B 050255 Light C 054920 Switch D 0...

Page 11: ...20V HIGH INPUT 002480 1 3000W 440V 013270 1 3750W 480V 006337 1 3300W 480V 005567 1 WASHER FLAT 10 7 16 OD 059502 2 2 2 WASHER LCKG INT TOOTH HI TEMP 10 011562 4 4 4 NUT 10 32 000361 2 2 2 2 HEAT DISP...

Page 12: ...10 Assembly instructions for griddle stand on casters There is no top on this stand...

Page 13: ...VII WIRING DIAGRAM 208 240 VOLT WIRING DIAGRAM 2011 ORG BLK BLK BLK thermostat RED TO TH TP ON GAS VALVE WHITE TO TP TERMINAL ON GAS VALVE TO TH ON GAS VALVE TO TH TP ON GAS VALVE TO PILOT ON GAS VAL...

Page 14: ...12 208 240 VOLT WIRING DIAGRAM 3 PHASE CONNECTIONS...

Page 15: ...208 240 VOLT WIRING DIAGRAM SINGLE PHASE CONNECTIONS 13...

Page 16: ...14 480 VOLT WIRING DIAGRAM NOTE Griddles rated at 480 Volts use type D 1 thermostats which include On Off switches Separate On Off switches are not provided with these griddles...

Page 17: ...08 6 2 17 17 17 30 220 6 9 18 18 18 31 240 8 2 20 20 20 34 AMPS PER LINE THREE PHASE 3 ELEMENTS 2300 W EACH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 10 3 26 34 26 49 220 11 5 28 36 28 52 240 13 7 30...

Page 18: ...LTS kW SINGLE L1 L2 L3 PHASE 208 13 4 34 45 34 65 220 15 0 36 47 36 68 240 17 9 39 52 39 74 AMPS PER LINE THREE PHASE 5 ELEMENTS 3000 W EACH 60x30 A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 10 7 34 34...

Page 19: ...30 68 240 17 9 49 49 32 75 AMPS PER LINE THREE PHASE 4 ELEMENTS 3750 W EACH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 16 8 43 56 43 81 220 18 8 45 59 45 85 240 22 3 49 64 49 93 AMPS PER LINE THREE PH...