background image

SERVICE INFORMATION

If you have a service related question call 1-800-KEATING.

Please state the nature of the call; it will ensure speaking with the appropriate person.

Have your serial and model number available when ordering parts.

KEATING OF CHICAGO, INC.

8901 W. 50th Street, McCook, Illinios 60525-6001

Phone: (708) 246-3000   FAX: (708) 246-3100

Toll Free 1-800-KEATING (In U.S. and Canada)

www.keatingofchicago.com

*As continuous product improvement occurs, specifications may be changed without notice.

KEATING LIMITED WARRANTY CARD

P L E A S E   C O M P L E T E  A N D   M A I L AT O N C E – WA R R A N T Y I S   N O T I N   E F F E C T U N T I L C A R D   I S   R E T U R N E D .

WA R R A N T Y C A R D   I S  A L S O  AVA I L A B L E   T O   C O M P L E T E   O N   L I N E  AT Y O U R   C O N V E N I E N C E .

COMPANY: ______________________________________________________________________________________________________

ADDRESS: ______________________________________________________________________________________________________

CITY:

____________________________________________________________________ STATE:________________ ZIP:____________

DEALER: ________________________________________________________________________________________________________

DATE OF PURCHASE:__________________________________________________________ INVOICE NUMBER: __________________

SERIAL NUMBER: ____________________________________

FRYER          

FILTER SYSTEM            

GRIDDLE

REMARKS:__________________________________________

TOP-SIDE COOKER     

HOT PLATE   

PASTA PLUS

I HAVE READ THE INSTALLATION AND OPERATION INSTRUCTIONS.

SIGNED: __________________________________________________________________________ DATE: ______________________

“Serving Those Who Serve The Very Best”

®

Summary of Contents for Griddle

Page 1: ...LY 9 STAND ASSEMBLY 10 WIRING DIAGRAMS 11 14 24 DEEP MODELS 15 30 DEEP MODELS 16 36 DEEP MODELS 17 CONTENTS IMPORTANT Keep a copy of your bill of sale The date on the bill establishes the warranty per...

Page 2: ...E VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OP...

Page 3: ...Electrical Code CAN 22 2 as applicable Your ventilation hood when installed must conform to the current ANSI NFPA 96 standard Installation clearance requires 6 from rear and side walls You must mainta...

Page 4: ...the current ANSI NFPA 96 standard ALL connections and placement must comply with local and national codes It is the responsibility of the owner and local installer to comply with these regulations whe...

Page 5: ...be found on its serial number tag Consult the National Electrical Code Handbook for additional information or to help answer questions about wire size selection For runs greater than 75 up to 125 use...

Page 6: ...ement of elements under MIRACLEAN plate 5 After each load scrape the griddle surface completely clean using the 4 wide replaceable blade scraper NOTE DO NOT HACK CHOP HIT OR CUT ON THE MIRACLEAN SURFA...

Page 7: ...40 Volt Unit Turn each thermostat fully counterclockwise and On Off switch to OFF position For 480 Volt Unit Turn thermostat knob to OFF position IV MAINTENANCE WARRANTY REPAIRS Keating s warranty beg...

Page 8: ...position Place thermometer on plate over bulb half way toward rear of griddle Figure 4 1 Thermostat calibration 4 If calibration of griddle is found to be less than 50 F off simply loosen four dial p...

Page 9: ...wer b Reset circuit breakers External c Set On Off switch to ON position d Turn thermostat to desired cooking temperature e Replace On Off switch f Replace thermostat g Tighten connections h Replace e...

Page 10: ...rmostat 400 F 029521 Thermostat 550 F 034870 Thermostat Dial Plate 400 F 060105 Thermostat Dial Plate 550 F 004163 Thermostat Knob 400 F 038267 Thermostat Knob 550 F B 050255 Light C 054920 Switch D 0...

Page 11: ...20V HIGH INPUT 002480 1 3000W 440V 013270 1 3750W 480V 006337 1 3300W 480V 005567 1 WASHER FLAT 10 7 16 OD 059502 2 2 2 WASHER LCKG INT TOOTH HI TEMP 10 011562 4 4 4 NUT 10 32 000361 2 2 2 2 HEAT DISP...

Page 12: ...10 Assembly instructions for griddle stand on casters There is no top on this stand...

Page 13: ...VII WIRING DIAGRAM 208 240 VOLT WIRING DIAGRAM 2011 ORG BLK BLK BLK thermostat RED TO TH TP ON GAS VALVE WHITE TO TP TERMINAL ON GAS VALVE TO TH ON GAS VALVE TO TH TP ON GAS VALVE TO PILOT ON GAS VAL...

Page 14: ...12 208 240 VOLT WIRING DIAGRAM 3 PHASE CONNECTIONS...

Page 15: ...208 240 VOLT WIRING DIAGRAM SINGLE PHASE CONNECTIONS 13...

Page 16: ...14 480 VOLT WIRING DIAGRAM NOTE Griddles rated at 480 Volts use type D 1 thermostats which include On Off switches Separate On Off switches are not provided with these griddles...

Page 17: ...08 6 2 17 17 17 30 220 6 9 18 18 18 31 240 8 2 20 20 20 34 AMPS PER LINE THREE PHASE 3 ELEMENTS 2300 W EACH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 10 3 26 34 26 49 220 11 5 28 36 28 52 240 13 7 30...

Page 18: ...LTS kW SINGLE L1 L2 L3 PHASE 208 13 4 34 45 34 65 220 15 0 36 47 36 68 240 17 9 39 52 39 74 AMPS PER LINE THREE PHASE 5 ELEMENTS 3000 W EACH 60x30 A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 10 7 34 34...

Page 19: ...30 68 240 17 9 49 49 32 75 AMPS PER LINE THREE PHASE 4 ELEMENTS 3750 W EACH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 16 8 43 56 43 81 220 18 8 45 59 45 85 240 22 3 49 64 49 93 AMPS PER LINE THREE PH...

Page 20: ...08 10...