background image

5

Push the fryer forward as far as it will go holding the
fryer on approximately a 15° angle, and then drop the
rear of the pasta cooker into its proper position lowering
it down gently so you do not deform the table or
equipment stand.

POSITIONING

The pasta cooker must be no closer than 6" from any
combustible material. When placed under an exhaust
hood with a fire retardant system it must comply with
ANSI/UL 507-(Latest Edition) and ANSI/NFPA 96-
(Latest Edition). No frame or restriction can be
constructed around the lower part of the pasta cooker
that would restrict ventilation or air movement into the
pasta cooker. You must insure adequate air supply to
the pasta cooker.

Adequate clearance for servicing and proper operation
must be maintained. Your pasta cooker is designed to
be serviced from the front. Do not place a pasta cooker
next to a deep fat fryer. Hot oil and water can cause an
unstable condition creating a hazardous situation.

LEVELING

The Pasta System will operate at its highest efficiency
when properly leveled. Place a level on Pasta System
vessel from side to side. For Pasta Systems on legs, the
bottom foot of the leg is adjustable. Turn counter
clockwise to decrease height or clockwise to increase
height until level. For Pasta Systems on casters, the
casters are adjustable by loosening the jam nut and
turning the caster in or out. When the desired level is
reached, tighten the jam nut. Adjustments of more than

3

/

4

" are not recommended on any caster. The same

procedure should be followed to level the Pasta System
from front to back. 

Figure 2-1

RESTRAINING 
DEVICES

On Custom Pasta

System

installations with casters, casters and
jam nuts must be completely
tightened. Adequate means must also
be provided to limit the movement of
the appliance without depending on
the connector, the quick-disconnect
device or its associated piping to limit
the appliance movement. 

Connectors must comply with ANSI Z21.69/CAN1
CAN/CGA 6.16 (latest edition) for connectors for
movable gas appliances. Quick-disconnect devices
must comply with ANSI Z21.41/CAN 1 6.9 (or latest
edition) standard for quick-disconnect devices for use
with gas fuel as applicable.

IF DISCONNECTION OF THE RESTRAINT IS
NECESSARY, IT MUST BE RECONNECTED WHEN
THE CUSTOM PASTA

SYSTEM IS RETURNED TO

ITS ORIGINALLY INSTALLED POSITION.

ELECTRICAL CONNECTION

Your pasta cooker has been ordered in either 1 phase
or 3 phase by your dealer. All electrical connections
should be made by a licensed electrician. If necessary
this unit can be field changed from 1 phase to 3 phase
or from 3 phase to 1 phase. Have a qualified electrician
refer to the wiring diagram.

ALL ELECTRICAL WIRING LEADING TO THE PASTA
COOKER MUST CONFORM TO LOCAL CODES. BE
SURE THE ON/OFF SWITCH IS IN THE OFF
POSITION BEFORE TURNING THE POWER ON TO
THE PASTA COOKER.

WATER AND DRAIN CONNECTION

The water is to be connected to the 

3

/

8

" female pipe

connection on the cabinet back, for auto-fill and the
optional faucet.

Make sure this and all other connections do not leak.
Check your water pressure. The auto-fill system is not
designed to handle pressure greater than 60 psi. Any
pressure greater than this can damage the auto-fill
solenoid or cause the system to fail. If the pressure is
greater than 60 psi a pressure regulator should be
added. The water temperature must not exceed 150°F
(65.6°C). Hot or warm water is not needed due to the
instant recovery of the Custom Pasta

System. 

If during operation the boil is killed when water
automatically enters the pasta cooker, turn the water
pressure down until the water is added without killing
the boil. The drain terminates within inches of the floor
and is designed for the standard dump to drain opening.

WARNING

Restraining devices

required.

CLEARANCES

Combustible

Construction

Non-Combustible

Construction

Back

6"

0"

Right Side

6"

0"

Left Side

6"

0"

Caster

Leg

Summary of Contents for 24763

Page 1: ...KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com Part 024763 Electric Pasta 0709 7 09 CUSTOM PASTA SYSTEM ELECTRIC SERVICE MANUAL...

Page 2: ...nufacturer of all warrant and liability Keating of Chicago Inc manufacturer reserves the right to change specifications at any time IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE C...

Page 3: ...Calibration 9 10 Auto Fill Safety Shut Off 10 Sensor Tube Cleaning 10 SECTION V SERVICE DIAGNOSIS Auto Fill System 11 Cooker Heating Section 11 Troubleshooting Charts 12 13 SECTION VI PARTS LIST Orde...

Page 4: ...ic timers Low water safety shutoff 1 full port front drain valve on 14 11 4 for 18 and larger High temperature limit control with manual reset Patented accurate temperature control system 2 F Ideal 35...

Page 5: ...power panel before servicing NEVER leave a pasta system unattended during operation NEVER move a pasta system when full of hot water NEVER introduce objects or liquids into pasta system while operati...

Page 6: ...en file a claim with the carrier since such damage is the carrier s responsibility By following these instructions carefully we guarantee our full support of your claims to protect you against loss fr...

Page 7: ...device or its associated piping to limit the appliance movement Connectors must comply with ANSI Z21 69 CAN1 CAN CGA 6 16 latest edition for connectors for movable gas appliances Quick disconnect devi...

Page 8: ...difference between the two thermostats Having less than a twenty degree difference will increase the possibility of a boil over and cause the pasta cooker to short cycle The recommended starting tempe...

Page 9: ...t Lift Model 1 Fill Pasta System as described on page 6 Filling 2 Set primary left thermostat to 212 F 100 C and secondary right thermostat to 190 F 87 8 C 3 Fill basket s to proper level and place on...

Page 10: ...turn ON and the display will now be indicating OR The BEEPER will BEEP 4 times NOTE If STEP 1 was OK proceed to STEP 2 If not retry Step 1 making sure the power was OFF for at least 30 seconds or more...

Page 11: ...any maintenance problem is directly or indirectly related to cleanliness NOTE Water level problems caused by the sensors not being cleaned adequately will not be covered under warranty NOTE Use of sod...

Page 12: ...cleaning Control of the water level is fully automatic with the auto fill system The water level is controlled by two circuit boards and two sensors The sensors are located in the tube on the right s...

Page 13: ...it The potentionmeter adjusts the sensitivity of the probe Adjusting this sensor will not increase the depth of the water Improper adjustments can effect the operation of the cooker and cause damage...

Page 14: ...not minutes or seconds 1 Reset the timer see pages 8 9 Water leaking in the rear of the pasta cooker 1 Replace fill hose Part 037390 sold per foot Breakers continue to trip 1 Ensure all wires to the c...

Page 15: ...echanism does not operate a Connections are loose or timer is faulty b Motor limit switch is faulty c Lift motor is faulty d Actuator is faulty e Control circuit fuse has blown f Relay is faulty a Tig...

Page 16: ...1 Custom Pasta System Electric Control Panel 1 2 3 2 4 5 6 6 7 7 ORDERING PARTS Parts may be ordered by part number by calling Keating at 1 800 KEATING or your local servce company You may also order...

Page 17: ...SMALL 002565 CIRCUIT BREAKER 40AMP 1P 012129 4 6 6 4 FUSE 300V 3AMP 004334 2 2 2 2 CONTACTOR 110V 3P 50AMP 011225 3 3 3 2 CONTRACTOR 110V 4P 40AMP 005597 1 TRANSFORMER STEPDOWN 004376 1 1 1 1 220 110V...

Page 18: ...16 VII WIRING DIAGRAMS 14 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS 2...

Page 19: ...14 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM 17...

Page 20: ...18 14 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Page 21: ...19 14 ELECTRIC PASTA WITH BASKET LIFT AND DIGITAL TIMERS WIRING DIAGRAM...

Page 22: ...20 18 20 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM PRE 2000 SERIES BLACK DIAL TIMER NOT DIGITAL...

Page 23: ...21 18 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...

Page 24: ...22 24 ELECTRIC PASTA WITH DIGITAL TIMERS WIRING DIAGRAM...

Page 25: ...OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installatio...

Page 26: ...______________ INVOICE NUMBER __________________________ SERIAL NUMBER ______________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS ____________________________________ TOP SIDE COOKER HOT PLATE...

Reviews: