background image

Keating Custom Pasta

Systems are intended for

other than household use.

ALWAYS instruct new employees on proper pasta
system operation.

A Custom Pasta System

should be operated 

ONLY by properly trained personnel.

ALWAYS turn pasta system off each night.

ALWAYS turn pasta system off at customer power
panel before servicing.

NEVER leave a pasta system unattended during 
operation.

NEVER move a pasta system when full of hot 
water.

NEVER introduce objects or liquids into pasta 
system, while operational, which are not designed
or made for cooking.

THIS CUSTOM PASTA

SYSTEM MAY NOT BE 

ALTERED, MODIFIED OR CHANGED IN ANY
WAY. 

IF THE EQUIPMENT IS NOT

INSTALLED, OPERATED AND
MAINTAINED IN ACCORDANCE
WITH THE ABOVE,
CONCENTRATIONS OF CARBON
MONOXIDE IN EXCESS OF THE
ESTABLISHED LIMITS COULD BE
PRESENT IN THE KITCHEN
ENVIRONMENT.

ALL PERSONNEL IN THE WORK PLACE WHO MAY
BE SUBJECT TO ANY EXPOSURE OF CARBON
MONOXIDE MUST

BE WARNED OF SUCH

POSSIBLE EXPOSURE. THIS WARNING SHOULD
BE CONVEYED IN A MANNER SO THAT IT IS
CLEARLY UNDERSTOOD BY THE EMPLOYEE, AND
THE EMPLOYEE SHOULD BE ASKED IF IN FACT HE
OR SHE UNDERSTANDS THE CORRECT METHOD
OF OPERATION OF THE EQUIPMENT AND THAT A
RISK OF EXPOSURE EXISTS IF THE EQUIPMENT
IS OPERATED IMPROPERLY.

IF NOT INSTALLED, OPERATED AND MAINTAINED
IN ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS, THIS PRODUCT COULD EXPOSE
YOU TO SUBSTANCES IN FUEL OR IN FUEL
COMBUSTION WHICH CAN CAUSE DEATH OR
SERIOUS ILLNESS AND WHICH ARE KNOWN TO
THE STATE OF CALIFORNIA TO CAUSE CANCER,
BIRTH DEFECTS OR OTHER REPRODUCTIVE
HARM.

II INSTALLATION

This Custom Pasta

System MUST

be installed, inspected, calibrated
and serviced by qualified and/or
certified and/or licensed service
personnel – you may void your
Keating warranty if installation is not
completed per current local, national
and Keating specifications. Contact
your dealer for assistance.

DAMAGE DURING 
SHIPMENT

The Custom Pasta

System has been assembled,

tested and inspected at the factory. Upon arrival, the
complete Pasta System should be checked for any
damage that may have occurred during shipment.

The carrier is responsible for all damage in transit
whether visible or concealed. Do not pay for the freight
bill until the Custom Pasta

System has been

thoroughly checked for damage. If concealed damage
is found later, contact the carrier immediately to file a
claim.

WHAT TO DO IF EQUIPMENT
ARRIVES DAMAGED:

VISIBLE LOSS OR DAMAGE

— Be certain to

note this on the freight or express receipt and
have it signed by the delivery person.

FILE CLAIM FOR DAMAGES
IMMEDIATELY

— Regardless of extent of

damage.

CONCEALED LOSS OR DAMAGE

— If

damage is noticed when equipment is
unpacked, notify the freight company
immediately, and file a “concealed damage
claim”. This MUST be done immediately. Be
sure to retain the shipping container for
inspection.

Keating does not assume responsibility for Loss OR
Damage incurred in transit.

NOTE:

Interstate commerce regulations require that

the claim must be initiated by the consignee within 10
days from the date it is received.

IT MAY BE NECESSARY TO INSTALL A BACK
FLOW OR CHECK VALVE ON THE WATER SUPPLY
LINE TO THE PASTA COOKER. CHECK WITH
EITHER YOUR LOCAL

WATER OR HEALTH

DEPARTMENT TO DETERMINE IF THIS IS
NECESSARY IN YOUR SPECIFIC AREA.

WARNING

Improper installation
can cause damage,
injury or death.

WARNING

Improper installation
can cause damage,
injury or death.

3

Summary of Contents for 240V

Page 1: ...KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com Part 000000 Electric Pasta 0107 09 07 CUSTOM PASTA SYSTEM ELECTRIC SERVICE MANUAL...

Page 2: ...nufacturer of all warrant and liability Keating of Chicago Inc manufacturer reserves the right to change specifications at any time IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE C...

Page 3: ...4 B Calibration 4 SECTION V SERVICE AND PARTS INFORMATION Auto Fill System 4 5 Cooker Heating Section 5 Ordering Parts 5 SECTION VI SERVICE DIAGNOSIS Troubleshooting 6 8 SECTION VII PARTS LIST Contro...

Page 4: ...ETL Sanitation Certified listed MODEL VARIATIONS Basket Lift Model Basket Lift Model Pasta Systems come with all the same features as the standard models The Basket Lift mechanism lowers the baskets...

Page 5: ...m MUST be installed inspected calibrated and serviced by qualified and or certified and or licensed service personnel you may void your Keating warranty if installation is not completed per current lo...

Page 6: ...e appliance without depending on the connector the quick disconnect device or its associated piping to limit the appliance movement Connectors must comply with ANSI Z21 69 CAN1 CAN CGA 6 16 latest edi...

Page 7: ...ss than a twenty degree difference will increase the possibility of a boil over and cause the pasta cooker to short cycle The recommended starting temperatures for the cooker are 212 F 98 8 C for the...

Page 8: ...l Pasta System as described on page 5 Filling 2 Set primary left thermostat to 212 F 100 C and secondary right thermostat to 190 F 87 8 C 3 Fill basket s to proper level and place on upper basket hang...

Page 9: ...lugged two people may be needed The timer will turn ON and the display will now be indicating OR The BEEPER will BEEP 4 times NOTE If STEP 1 was OK proceed to STEP 2 If not retry Step 1 making sure th...

Page 10: ...ten WHEN THE WATER LEVEL FALLS BELOW THE BOTTOM WATER SENSOR THE HEATING ELEMENTS WILL TURN OFF IF THEY CONTINUE TO HEAT TURN THE MAIN POWER SWITCH OFF AND CHECK AUTO FILL SYSTEM LIMITED CALIBRATION C...

Page 11: ...art to fill until the water level reaches the upper sensor The burners will not come on until the water level reaches the lower sensor preventing the Pasta System from being damaged if there is little...

Page 12: ...he safety or low level board The A board is connected to the bottom sensor and turns the elements off when the water falls below the level of sensor The B board is connected to the top sensor and adds...

Page 13: ...inutes or seconds 1 Reset the timer see instructions Water leaking in the rear of the pasta cooker 1 Replace fill hose Part 033495 sold per foot Breakers continue to trip 1 Ensure all wires to the con...

Page 14: ...hanism does not operate a Connections are loose or timer is faulty b Motor limit switch is faulty c Lift motor is faulty d Actuator is faulty e Control circuit fuse has blown f Relay is faulty a Tight...

Page 15: ...T WATER FILLING 1 009256 5 MANUAL WATER FILL BUTTON 1 004304 NUT WITH BOOT 1 009389 6 DIGITAL TIMERS 2 056921 14 BASKET LIFT TIMER Not Shown 2 023709 7 THERMOSTAT 2 031466 THERMOSTAT KNOB 2 004163 DIA...

Page 16: ...76 1 1 1 1 220 110V 60Hz CIRCUIT BREAKER 50 AMP 3 033891 1 1 1 1 DOOR CATCH ROLLER STYLE ALL 004540 1 1 1 1 WATER FILL SOLENOID ALL 008133 1 1 1 1 HOSE CLAMP ALL 004167 2 2 2 2 WATER FILL HOSE CALL 1...

Page 17: ...ONT 1 026813 DRAIN VALVE HANDLE 1 DRAIN 1 016387 PARTS LIST FOR 18 CUSTOM PASTA SYSTEM DESCRIPTION QTY PART HEATING ELEMENT 2 004353 SOLENOID VALVE 1 010608 CONTACTOR 1 011225 DRAIN VALVE 11 4 1 01634...

Page 18: ...16 VIII WIRING DIAGRAMS 14 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...

Page 19: ...17 14 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM...

Page 20: ...18 18 20 ELECTRIC PASTA WITH 138 TIMERS WIRING DIAGRAM...

Page 21: ...19 18 ELECTRIC PASTA 2 THERMOSTAT WIRING DIAGRAM WITHOUT TIMERS...

Page 22: ...FOR PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting fr...

Page 23: ...____________ INVOICE NUMBER __________________________ SERIAL NUMBER ______________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS ____________________________________ TOP SIDE COOKER HOT PLATE C...

Reviews: