background image

As continuous product improvement occurs, specifications may be changed without notice.

SPECIFICATIONS

The Keating Instant Recovery

®

Counter Model Fryer consists of a

frying vessel 14" sq., having a splash deck and a splash back
installed in a cabinet equipped with gas burners and an automatic
temperature control mechanism, all arranged and designed for the
proper frying of food.

FRYING VESSEL: 

shall have coved seamless corners and be

drawn from 18 gauge stainless steel, shall have a shortening
capacity of 38 pounds, shall be equipped with three 18 gauge
horizontal heat transfer tubes spaced above the bottom of the
vessel so that the bottom is unheated and the food particles col-
lecting in this bottom zone are unheated and therefore do not
carbonize. The frying vessel shall be polished to inhibit carbon
build-up and facilitate wasy clean-up.

The heat transfer tubes

shall be 3" wide and 5" high. The bottom of the vessel shall slope
toward the front where it shall be equipped with a 1" Teflon core 

1

/

4

turn, drain valve, so arranged that the shortening can be drained
into a receiving vessel placed in front of the fryer.

Slashdeck

shall slope toward the shortening containing vessel.

The splash deck shall be made of 16 gauge 304 stainless steel.

Splashback 

shall be made of 18 gauge 304 stainless steel, shall

completely cover the sides of the flue.

CABINET: 

shall be made of 18 gauge stainless steel. The cabinet

shall be rigid in construction and shall have four 4" adjustable
legs. A door made of 22 gauge 304 stainless steel

shall cover the

front of the cabinet and shall extend from the bottom of the fryer to

the panel, and above the panel shall be a canopy. The door
shall be the full width of the cabinet. No additional space is
required for the door to open a full 90 degrees. A stainless
steel flue deflector is provided for installing onto the flue
back.

Heat Transfer Tubes

to be three, made of stainless steel

polished to a #7 mirror finish.

Thermostat

shall be close range, hydraulic type and be accu-

rate to ±3°F from 300° to 350°F with stainless steel bulb.
Application of this thermostat is patented by Keating.

Hi-Limit Control

shall be manually resettable type with

stainless steel bulb.

100% Safety Shut Off

shall be millivolt type with combina-

tion control gas valve and thermopile.

Standard Accessories

to include one pair 4 mesh baskets,

grid screen over heat transfer tubes, drain clean out rod, 
1"×11

1

/

2

"drain extension and sample of Keating Klenzer and

Sea Powder.

Electric Requirements 

are not necessary.

Gas Requirements

to install are 

3

/

4

" male NPT connection and

4" water column pressures natural and 10" for LP gas at the
fryer burner manifold. Supply pressure to fryers must be 7”
(natural gas) and 11” (LP) water column.

Special Order Options

may include cover, full or triple size

baskets, thermostat seal, portable filter, security package.

COUNTER MODEL INST

ANT RECO

VER

Y

®

FR

YER

14 CMG GAS

Printed in U.S.A.

14CMG2006

12/06

Oil

BTU

Working

Overall

Ship

Model No. and Description

Capacity

Input

Height 

Height

Depth

Width

Wt.

14 CMG Nat Gas

38 lbs.

87,000

19

3

/

8

27

3

/

8

"

27

1

/

2

"

15

3

/

8

"

130 lbs.

14 CMG LP Gas

38 lbs.

90,000

19

3

/

8

27

3

/

8

"

27

1

/

2

"

15

3

/

8

"

130 lbs.

KEATING OF CHICAGO, INC.

Toll Free 1-800-KEATING

www.keatingofchicago.com

14 COUNTER MODEL GAS

Reviews: