background image

W

a

rr

a

n

ty

Li

m

it

ed

 W

a

rr

a

n

ty

Kea

ting 

of 

Chicago

, I

nc

. (“Kea

ting

”) 

w

ar

ran

ts 

to 

the 

or

ig

inal 

pur

chaser

. (“

Cust

omer

”), 

all 

new 

Kea

ting 

Fr

yers

Filt

er S

yst

ems

, Gr

iddles

, Keep K

risp®, C

ust

om P

asta S

yst

ems

, T

op

-Side™ C

ookers

, C

omput

er 

Timers

, F

ry

er & 

Pasta 

Vessels 

and 

Kea

ting 

replac

emen

t par

ts 

(“

pr

oduc

ts

”) 

installed 

af

ter 

June 

1, 

1994 

to 

be 

fr

ee 

to 

def

ec

ts 

in 

ma

ter

ial or w

or

kmanship

, subjec

t t

o the f

ollo

wing t

er

ms and c

onditions

.

Le

n

g

th

 O

W

a

rr

a

n

ty

A

ll 

pr

oduc

ts 

other 

than 

Fr

yer 

Pasta 

Vessels 

and 

replac

emen

t par

ts 

shall 

be 

w

ar

ran

ted 

for 

per

iod 

of 

one 

year 

fr

om 

the 

da

te 

of 

or

ig

inal 

equipmen

t installa

tion. 

Kea

ting 

replac

emen

t par

ts 

ar

w

ar

ran

ted 

for 

a per

iod 

of 

ninet

y da

ys fr

om the da

te of installa

tion. F

ry

er & P

asta 

Vessels ar

e w

ar

ran

ted as descr

ibed belo

w

.

fr

ye

&

 P

a

st

a

 V

es

se

W

a

rr

a

n

ty

Fr

yers 

pur

chased 

af

ter 

June 

1, 

1994 

car

ry 

pr

or

at

ed 

vessel 

w

ar

ran

ty 

on 

def

ec

ts 

in 

ma

ter

ials 

or 

w

or

kmanship 

to the C

ust

omer based on the f

ollo

wing scale:

 

Time fr

om I

nstalla

tion Da

te

 

Fr

yer 

Vessel 

W

ar

ran

ty C

redit

 

13-60 mon

ths

 

100%

 

61-72 mon

ths

 

80%

 

73-84 mon

ths

 

60%

 

85-96 mon

ths

 

40%

 

97-108 mon

ths

 

20%

 

109-120 mon

ths

 

10%

The cr

edit f

or the def

ec

tiv

e fr

yer & pasta v

essel shall be applied against the c

ost of the r

eplac

emen

vessel

, utilizing Kea

ting

’s then cur

ren

t pr

ic

e, upon r

etur

n of the v

essel t

o Kea

ting only dur

ing the first 60 

mon

ths

, subjec

t t

o the limita

tions descr

ibed belo

w

.

Li

m

it

at

iO

n

O

Li

a

bi

Li

ty

In the ev

en

t of w

ar

ran

ty claim or other

wise

, the sole obliga

tion of Kea

ting shall be the r

epair and / or 

replac

emen

t a

t the 

option 

of 

Kea

ting 

of 

the 

pr

oduc

t or 

componen

t or 

par

t ther

eof

. Such 

repair 

or 

replac

emen

shall 

be 

at 

the 

expense 

of 

Kea

ting 

ex

cept 

tha

t the 

Cust

omer 

shall 

pa

the 

follo

wing 

expenses: 

all 

fr

eigh

t and 

labor e

xpense f

or Kea

ting r

eplac

emen

t par

ts; f

or all other pr

oduc

ts

, mileage e

xc

eeding 50 miles or tr

av

el 

mor

than 

one 

hour

, labor 

costs 

of 

mor

than 

one 

person, 

ov

er

time 

ra

tes

, truck 

char

ges

, diff

er

enc

bet

w

een 

gr

ound 

and 

other 

mode 

of 

tr

anspor

ta

tion, 

and 

holida

y char

ges

. A

ny 

repair 

or 

replac

emen

t under 

this 

Limit

ed 

W

ar

ran

ty 

does 

not 

constitut

an 

ex

tension 

of 

the 

or

ig

inal 

w

ar

ran

ty 

for 

an

per

iod 

for 

the 

pr

oduc

t or 

for 

an

componen

t or 

par

t ther

eof

. P

ar

ts 

to 

be 

replac

ed 

under 

this 

Limit

ed 

W

ar

ran

ty 

will 

be 

repair

ed 

at 

the 

option 

of 

Kea

ting 

with 

new 

or 

func

tionally 

oper

ativ

par

ts

. Keep 

Kr

isps 

and 

Comput

er 

Timers 

must 

be 

retur

ned 

to 

Kea

ting f

or w

ar

ran

ty r

epair or r

eplac

emen

t. F

ield r

epairs of those it

ems ar

e not author

iz

ed

.

T

he

 

liabili

Ty

 

of

 K

ea

Ting

 

on

 

an

y

 

claim

 

of

 

an

y

 

Kind

including

 

claims

 

based

 

on

 

w

ar

ran

Ty

expr

essed

 

or

 

implied

con

Tr

ac

T

negligenc

e

sT

ric

T

 

liabili

Ty

 

or

 

an

y

 

o

Ther

 

Theor

ies

 

shall

 

be

 

solely

 

and

 

ex

clusiv

ely

 

The

 

repair

 

or

 

replac

emen

T

 

of

 

The

 

pr

oduc

T

 

as

 

sT

a

Ted

 

her

ein

and

 

such

 

liabili

Ty

 

shall

 

no

T

 

include

and

 

cus

Tomer

 

specifically

 

renounc

es

 

an

y

 

righ

Ts

 

To

 

rec

o

ver

special

inciden

Tal

consequen

Tial

 

or

 

o

Ther

 

injur

ies

 

To

 

persons

 

or

 

damage

 

To

 

pr

oper

Ty

loss

 

of

 

pr

ofi

Ts

 

or

 

an

Ticipa

Ted

 

pr

ofi

Ts

or

 

loss

 

of

 

use

 

of

 

The

 

pr

oduc

T

If 

an

or

al 

sta

temen

ts 

ha

ve 

been 

made 

regar

ding 

the 

Kea

ting 

pr

oduc

ts

, such 

sta

temen

ts 

do 

not 

constitut

w

ar

ran

ties and ar

e not par

t of the c

on

tr

ac

t sale

. T

his Limit

ed 

W

ar

ran

ty c

onstitut

es the c

omplet

e, final and 

ex

clusiv

e sta

temen

t with r

egar

d t

o w

ar

ran

ties

T

his

 

limi

Ted

 

w

ar

ran

Ty

 

is

 

ex

clusiv

e

 

and

 

is

 

in

 

lieu

 

of

 

all

 

o

Ther

 

w

ar

ran

Ties

 

whe

Ther

 

wr

iTT

en

or

al

sT

a

Tu

Tor

y

 

or

 

implied

including

 

bu

T

 

no

T

 

limi

Ted

 

To

 

an

y

 

w

ar

ran

Ty

 

of

 

mer

chan

Tabili

Ty

 

or

 

fi

Tness

 

for

 

par

Ticular

 

pur

pose

 

or

 

w

ar

ran

Ty

 

agains

T

  

la

Ten

T

 

def

ec

Ts

.

ex

c

Lu

si

O

n

s

The w

ar

ran

ties pr

ovided b

y Kea

ting of Chicago

, I

nc

. do not apply in the f

ollo

wing instanc

es:

1.

 D

ef

ec

ts 

ar

ising 

out 

of 

or 

resulting 

fr

om 

impr

oper 

installa

tion 

or 

main

tenanc

e, 

abuse

, misuse

, modifica

tion 

or alt

er

ation b

y unauthor

iz

ed ser

vic

e personnel

, or an

y other c

ondition not a

ttr

ibutable t

o a def

ec

t in 

ma

ter

ial 

or 

w

or

kmanship

. P

roper 

installa

tion 

and 

main

tenanc

ar

the 

responsibilit

of 

the 

installer 

and 

Cust

omer

, r

espec

tiv

ely

. P

roper installa

tion and main

tenanc

e pr

oc

edur

es ar

e pr

escr

ibed b

y the Kea

ting 

Ser

vic

e M

anual

.

2.

 In 

the 

ev

en

t tha

t the 

pr

oduc

t w

as 

damaged 

af

ter 

lea

ving 

the 

fac

tor

due 

to 

flood

, fir

e, 

other 

ac

ts 

of 

G

od 

or 

ac

ciden

t, 

damage 

dur

ing 

shipmen

t should 

be 

repor

ted 

to 

the 

car

rier 

and 

is 

not 

the 

responsibilit

y of 

Kea

ting

.

3.

 In the ev

en

t the ser

ial number or r

ating pla

te has been r

emo

ved fr

om the pr

oduc

t or alt

er

ed

.

4.

 On 

par

ts 

which 

w

ould 

nor

mally 

be 

w

or

or 

replac

ed 

under 

nor

mal 

conditions

, including 

but 

not 

limit

ed 

to 

elec

tr

ic bulbs

, fuses

, in

ter

ior and e

xt

er

ior finishes

, gaskets and r

adian

ts

.

5.

 W

ith r

egar

d t

o adjustmen

ts and calibr

ations such as lev

eling

, tigh

tening of fast

eners or plumbing 

connec

tions

, impr

oper gas pr

essur

e or impr

oper elec

tr

ical supply

, the check

ing of and changes in 

adjustmen

t and calibr

ations ar

e the r

esponsibilit

y of the installer

. P

roper installa

tion pr

oc

edur

es ar

pr

escr

ibed b

y the Kea

ting S

er

vic

e M

anual

.

6.

 In the ev

en

t of unauthor

iz

ed r

epairs or alt

er

ations t

o the Kea

ting pr

oduc

t.

7.

 W

ith the use of sodium chlor

ide in pasta v

essels or harsh chemicals in fr

yer or pasta v

essels

.

8.

 Installa

tion in Household

.

O

th

er

 t

er

m

a

n

d

 c

O

n

d

it

iO

n

s

The C

ust

omer must pr

ovide pr

oof of pur

chase fr

om Kea

ting

This Limit

ed 

W

ar

ran

ty is v

alid in the 50 Unit

ed S

ta

tes

, its t

er

rit

or

ies

, and C

anada, and is v

oid elsewher

e.

Kea

ting 

pr

oduc

ts 

ar

sold 

for 

commer

cial 

use 

only

. I

f an

Kea

ting 

pr

oduc

t is 

sold 

as 

componen

t of 

another 

pr

oduc

t or used as a c

onsumer pr

oduc

t, such Kea

ting pr

oduc

t is sold A

s Is without an

y w

ar

ran

ty

.

If an

y pr

ovision of this Limit

ed 

W

ar

ran

ty is held t

o be unenf

or

ceable under the la

w of an

y jur

isdic

tion, 

such pr

ovision shall be inapplicable in such jur

isdic

tion, and the r

emainder of the w

ar

ran

ty shall r

emain 

unaff

ec

ted

. F

ur

ther 

in 

such 

ev

en

t, 

the 

maximum 

ex

clusion 

or 

limita

tion 

allo

w

able 

under 

applicable 

la

shall 

be deemed substitut

ed f

or the unenf

or

ceable pr

ovision.

This 

Limit

ed 

W

ar

ran

ty 

shall 

be 

go

ver

ned 

by 

and 

construed 

in 

ac

cor

danc

with 

the 

la

w

s of 

the 

Sta

te 

of 

Illinois

.

tO

 s

ec

u

re

 W

a

rr

a

n

ty

 s

er

V

ic

e

A

ll r

epair ser

vic

es under this Limit

ed 

W

ar

ran

ty must be author

iz

ed b

y Kea

ting or per

for

med a

t Kea

ting

Author

iza

tion 

ma

y be 

obtained 

by 

calling 

1-800-KEA

TING 

within 

the 

Con

tinen

tal 

Unit

ed 

Sta

tes

, A

lask

a, 

Ha

w

aii, 

Puer

to 

Ric

and 

Canada 

dur

ing 

nor

mal 

business 

hours 

(8 

a.m. 

thr

ough 

p.m. 

Cen

tr

al 

Time

, M

onda

thr

ough 

Fr

ida

y). 

W

hen calling

, please ha

ve the f

ollo

wing inf

or

ma

tion a

vailable: (1) name

, addr

ess and t

elephone 

number 

of 

the 

Cust

omer

; (2) 

loca

tion 

of 

pr

oduc

t, 

if 

diff

er

en

t; 

(3) 

name

, model 

number 

and 

ser

ial 

number 

of 

the 

pr

oduc

t; 

(4) 

installa

tion 

da

te; 

and 

(5) 

descr

iption 

of 

def

ec

t. 

Kea

ting 

will 

then 

issue 

ser

vic

author

iza

tion 

w

or

or

der 

number 

to 

one 

of 

its 

appr

ov

ed 

independen

t ser

vicing 

or

ganiza

tions

, or 

request 

the 

pr

oduc

t or 

par

t be shipped t

o Kea

ting f

or r

epair or r

eplac

emen

t, as appr

opr

ia

te

. A

ny def

ec

tiv

e par

t subjec

t t

o a claim 

under 

this 

Limit

ed 

W

ar

ran

ty 

must 

be 

shipped 

fr

eigh

t pr

epaid 

to 

Kea

ting 

for 

testing 

and 

examina

tion. 

Kea

ting

’s 

decision as t

o the cause and na

tur

e of an

y def

ec

t under this Limit

ed 

W

ar

ran

ty shall be final

.

Kea

ting o

chica

go

, i

nc. | 1-800-kea

ting | www

.kea

tingo

fchica

go

.c

om

6/20

Summary of Contents for 10x11 TS

Page 1: ......

Page 2: ...ND CODE ADMINISTRATORS INTERNATIONAL INC BOCA AND THE FOOD SERVICE SANITATION MANUAL OF THE FOOD AND DRUG ADMINISTRATION FDA 9902091 9902091 i Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment Do not store or use gasoline o...

Page 3: ... and has American sizes of hardware All metric conversions are approximate INSTALLATION INSTRUCTIONS Proper installation will assure top performance Alterations of any kind to your equipment will void the warranty Before uncrating check equipment carefully for damage IF EQUIPMENT ARRIVES DAMAGED Keating does not assume responsibility for loss or damage incurred in transit IMPORTANT This merchandis...

Page 4: ...ed and raises the baskets when the cooking cycle is complete Split baskets are used for all models CM Model BB and TS Counter Model Fryers are equipped with all of the same features as the BB and TS Models respectively but take up less than three square feet of counter space The 10x11CM Model can cook up to 36 lbs of frozen fries per hour and the 14CM Model can cook up to 72 lbs per hour CPU Model...

Page 5: ...equip ment stand FIRST STEPS POSITIONING The fryer must be placed under an exhaust hood with a fire retardant system Your ventilation hood when installed must conform to the current standards ALL connections and placement must comply with current local and national codes It is the responsibility of the owner and local installer to comply with these regula tions when installing the fryer Counter mo...

Page 6: ...icable NOTE A copy of your wiring diagram is shipped with your equipment NOTE For fryers rated at 208 240 volts the amper age ratings marked on the nameplates of the fryers are listed at 240 volts as required by ETL If your fryer is to be fed by a 208 or 220 volt system consult the Keating Fryer Specifications on pages 36 and 37 to determine the full load rating of the fryer NOTE Fryers with Safe ...

Page 7: ...SKETS ON BASKET HANGERS OR FRYER VESSEL CARE SHOULD BE TAKEN WHEN LOWERING BAS KETS INTO FRYER TO PREVENT SPLASHING HOT OIL FROM FRYER VESSEL NEVER LIFT BASKETS DIRECTLY OUT OF THE FRYER VESSEL WITHOUT DRAINING AS SEVERE INJURY MAY RESULT NOTE For safety purposes all Hi Limit controls are manually reset Always check the Hi Limit reset button before attempting to use the fryer If the Hi Limit has t...

Page 8: ...Turn fryer Power switch to OFF position B CPU Model 1 Set Main Power On Off switch to the OFF position DRAINING ALWAYS SHUT THE FRYER OFF COMPLETELY BE FORE DRAINING THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL A DRAIN PIPE AND COV ERED CONTAINER SUITABLE FOR USE WITH HOT OIL SHOULD BE USED TO ENSURE THE SAFETY OF THE OPERATOR 1 Operator should be outfitted ...

Page 9: ...T BOIL OVER OR TO TURN OFF THE POWER IF WATER DROPS BELOW HEATING ELE MENTS 6 Set thermostat and turn fryer on to bring water to a gentle boil 7 Once boil has been reached turn fryer off 8 Dissolve 2 3 cup of Keating Sea Powder for every five gallons of water and let soak for 1 2 hour If there is a large build up of carbonized grease allow fryer to soak overnight DO NOT DAMAGE OR REMOVE THERMOSTAT...

Page 10: ...CELING A CYCLE To cancel a cycle in progress press and hold any but ton for approximately two seconds The relay output contacts will open and the display will show the time setting for the cook time last used MAINTENANCE WARRANTY REPAIRS Keating s warranty begins with the date of installa tion In the event that your Instant Recovery Fryer under warranty needs repairs other than routine maintenance...

Page 11: ...to match the thermometer reading DO NOT ADJUST THE THERMOSTAT SET SCREW IT VOIDS ANY WARRANTY ON PART NOTE Locate thermometer in same position for every calibration Position next to upper heating element is recommended Thermostat Bulb Positioning Keating s patented thermostat application is accurate within 7 F of the dial setting between 250 F and 350 F This accuracy is attained only if the thermo...

Page 12: ...is faulty g MELT FRY switch is faulty h Contactor is faulty i Thermostat is faulty a Connect fryer to an approved source of power b Connect 120V terminal block to an approved source of power c Reset circuit breakers d Push in Hi Limit Reset button located behind fryer door Check calibration of thermostat and operation of Hi Limit and contactor e Fully close and latch rear drain valve handle Turn f...

Page 13: ... c Connections are loose d Thermostat contacts do not close properly a Contact your electrician or the local power company and have the incoming power checked b Replace contactor c Tighten connections d Replace thermostat TS MODELS Basket Lift mechanism will not operate a Connections are loose or timer is faulty b Actuator is faulty c Control circuit breaker has tripped d Relay is faulty a Tighten...

Page 14: ... TEMP BB TS 011881 011881 2 Per Element FLAT WASHER 10 HI TEMP BB TS 059502 059502 2 Per Element NUT 10 32 BB TS 000361 000361 2 Per Element ITEM DESCRIPTION MODEL P N 10x11 14 18 20 24 34x24 Quantity Per Model 2 ELEMENT CLAMP ALL 004167 2 2 2 2 2 2 3 ELEMENT SPACER ALL 004145 4 4 4 FRYER VESSEL CALL 1 800 KEATING 1 1 1 1 1 1 5 DRAIN VALVE FRONT 1 BB TS 004553 1 1 DRAIN VALVE REAR 1 BB TS 016341 1...

Page 15: ...TEP DOWN 056037 1 1 1 1 1 1 9 FAT MELT INFINITE CONTROL 037470 1 1 1 1 1 1 10 HIGH LIMIT RESETTABLE 060806 1 1 1 1 1 1 11 CIRCUIT BREAKER 16 AMP 1 POLE 208 240V 057338 3 CIRCUIT BREAKER 32 AMP 1 POLE 208 240V 033885 6 CIRCUIT BREAKER 40 AMP 1 POLE 208 240V 033881 6 6 8 10 CIRCUIT BREAKER 10 AMP 1 POLE 480V 057336 3 CIRCUIT BREAKER 16 AMP 1 POLE 480V 057338 6 CIRCUIT BREAKER 20 AMP 1 POLE 480V 0339...

Page 16: ...R 4 POLE 40 AMP 053383 2 2 11 TRANSFORMER STEP DOWN 24VAC 75VA 056037 1 1 1 1 1 1 12 HIGH LIMIT RESETTABLE 060806 1 1 1 1 1 1 13 CIRCUIT BREAKER 16 AMP 1 POLE 208 240V 057338 CIRCUIT BREAKER 25 AMP 1 POLE 208 240V 033525 3 CIRCUIT BREAKER 32 AMP 1 POLE 208 240V 033885 CIRCUIT BREAKER 40 AMP 1 POLE 208 240V 033881 6 8 8 10 CIRCUIT BREAKER 13 AMP 1 POLE 480V 057337 3 CIRCUIT BREAKER 20 AMP 1 POLE 48...

Page 17: ...AMP 053385 2 2 CONTACTOR 4 POLE 40 AMP 053383 2 2 12 TRANSFORMER STEP DOWN 24VAC 75VA 056037 1 1 1 1 1 13 HIGH LIMIT RESETTABLE 060806 1 1 1 1 1 14 CIRCUIT BREAKER 16 AMP 1 POLE 208 240V 057338 CIRCUIT BREAKER 25 AMP 1 POLE 208 240V 033525 3 CIRCUIT BREAKER 32 AMP 1 POLE 208 240V 033885 CIRCUIT BREAKER 40 AMP 1 POLE 208 240V 033881 6 8 8 10 CIRCUIT BREAKER 13 AMP 1 POLE 480V 057337 3 CIRCUIT BREAK...

Page 18: ...385 CONTACTOR 4 POLE 40 AMP 053383 12 TRANSFORMER STEP DOWN 24VAC 75VA 056037 1 13 HIGH LIMIT RESETTABLE 060806 1 14 CIRCUIT BREAKER 16 AMP 1 POLE 208 240V 057338 CIRCUIT BREAKER 25 AMP 1 POLE 208 240V 033525 CIRCUIT BREAKER 32 AMP 1 POLE 208 240V 033885 CIRCUIT BREAKER 40 AMP 1 POLE 208 240V 033881 CIRCUIT BREAKER 13 AMP 1 POLE 480V 057337 CIRCUIT BREAKER 20 AMP 1 POLE 480V 033920 12 15 RELAY 030...

Page 19: ...40 AMP 1 POLE 208 240V 033881 12 6 HIGH LIMIT RESETTABLE 060806 1 7 RELAY DPDT 24 VAC 030844 1 8 RELAY DPDT 24 VDC 017673 1 9 MAGNETIC REED SWITCH 053777 2 10 COMPUTER PROBE 004776 1 11 CONTACTOR 50 AMP 3 POLE 033899 4 34x24 CPU CONTROL PANEL 208 240V with TOGGLE SWITCH not shown to scale Control Panel Front 1 2 3 Detail Area Contactor Tray Top View Rear Drain Unit Contactor Tray Front View Rear D...

Page 20: ...VAC 030844 2 13 RELAY DPDT 24VDC 017673 2 14 COMPUTER PROBE 004776 1 15 TRANSFORMER STEP DOWN 24VAC 75VA 056037 1 16 CIRCUIT BREAKER 40 AMP 1 POLE 208 240V 033881 6 17 CONTACTOR 50 AMP 1 POLE 033899 2 18 SPARK IGNITION MODULE 24VAC 058439 1 19 BRACKET SPARK IGNITION MODULE 056000 1 20 MAGNETIC REED SWITCH 053777 1 Spark Ignition Model Only Rear Drain Fryers Only CPU CONTROL PANEL 208 240V with ROC...

Page 21: ...FT ACTUATOR LOWER BL S S 054522 1 14 CONNECTOR 2 CIRCUIT PLUG 032208 1 CONNECTOR CONTACT PIN MALE 028309 2 15 PIN BASKET LIFT NON ROTATIONAL 054760 1 This circuit breaker can be found under the control panel on newer units BASKET LIFT POWER SUPPLY BOX BASKET LIFT ASSEMBLY Bottom View Top View 8 7 1 4 6 5 Top View Side View 2 3 Basket Lift Power Supply Box Basket Lift Assembly Housing 10 9 15 14 12...

Page 22: ...Y DPDT 24VAC 030844 2 RELAY DPDT 24VDC CPU MODEL 017673 2 3 RECTIFIER 24VDC 018321 1 4 BUSHING STRAIN RELIEF 5 8 HOLE 000470 2 5 BUSHING STRAIN RELIEF 3 4 HOLE 033800 1 NOTE Circuit breaker is located under the control panel BASKET LIFT POWER SUPPLY BOX 2007 CPU NON CPU Top View Side View 4 3 1 4 5 2 ...

Page 23: ...NTACT PIN MALE 028309 5 WIRING DIAGRAMS NOTE A separate wiring diagram has been included with this manual and should be saved for troubleshooting and maintaining the fryer The wiring diagrams in this section cover standard fryers which may or may not match the diagram sent with the fryer CPU models on pages 34 35 SINGLE BASKET LIFT POWER SUPPLY BOX ...

Page 24: ...WER SWITCH R RELAY 24VAC RDS REAR DRAIN VALVE SWITCH RP RECEPTACLE WITH POWER CORD APPLIES ONLY TO UNITS WITH FILTER TB TERMINAL BLOCK TH THERMOSTAT TR TRANSFORMER TS FAT MELT TIMER RELAY SWITCH WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER DISTRIBUTION BLOCK FM FAT MELT TIMER SWITCH GRD GROUND...

Page 25: ...P POWER SWITCH PO POWER ON LIGHT CLEAR TH THERMOSTAT TR TRANSFORMER NOTES 1 WIRES 1 TO 6 ARE 10 AWG 7 TO 15 ARE 12 AWG 2 ALL OTHER WIRES ARE 18 AWG WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GY GRAY GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER DISTRIBUTION BLOCK FM FAT MELT TIMER SWITCH GRD GROUNDING LUG HL HIGH LIMIT SWITCH MF MELT FR...

Page 26: ...WITCH P POWER SWITCH PO POWER ON LIGHT CLEAR TH THERMOSTAT TR TRANSFORMER NOTES 1 WIRES 1 TO 18 ARE 10 AWG 2 ALL OTHER WIRES ARE 18 AWG COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER DISTRIBUTION BLOCK FM FAT MELT TIMER SWITCH GRD GROUNDING LUG HL HIGH LIMIT SWITCH MF MELT FRY SWITCH P POWER SWITCH PO POWER ON LIGHT WHITE TH THERMOSTAT TR TRANSFORMER WIRE COLOR CODES BL BLACK BR BR...

Page 27: ... THERMOSTAT TR TRANSFORMER NOTES 1 FILTER RECEPTACLE POWER CORD APPLIES ONLY TO UNITS WITH FILTER 2 WIRES 1 TO 6 ARE 10 AWG WIRES 7 TO 18 ARE 10 AWG FOR 208 240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS 3 ALL OTHER WIRES ARE 18 AWG WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER DISTRIBUTION B...

Page 28: ...OSTAT TR TRANSFORMER NOTES 1 FILTER RECEPTACLE POWER CORD APPLIES ONLY TO UNITS WITH FILTER 2 WIRES 1 TO 8 ARE 10 AWG WIRES 9 TO 24 ARE 10 AWG FOR 208 240 VOLT UNITS AND 12 AWG FOR 480 VOLT UNITS 3 ALL OTHER WIRES ARE 18 AWG WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN GY GRAY OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER DISTRIBUTION BLO...

Page 29: ...RELAY 24VAC RDS REAR DRAIN VALVE SWITCH TH THERMOSTAT TR TRANSFORMER NOTES 1 FILTER RECEPTACLE POWER CORD APPLIES ONLY TO UNITS WITH FILTER 2 WIRES 1 TO 10 ARE 10 AWG WIRES 11 TO 30 ARE 10 AWG FOR 208 240 VOLT UNITS AND 12 AWG FOR 480 VOLT UNITS 3 ALL OTHER WIRES ARE 18 AWG COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER DISTRIBUTION BLOCK FM FAT MELT TIMER SWITCH GRD GROUNDING LUG ...

Page 30: ...WITCH OMT OVER MAX TEMP LIGHT RED P POWER SWITCH R RELAY 24VAC RDS REAR DRAIN VALVE SWITCH RTC READY TO COOK LIGHT GREEN TH THERMOSTAT TR TRANSFORMER WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GY GRAY GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER DISTRIBUTION BLOCK FM FAT MELT TIMER SWITCH GRD GROUNDING LUG HL HIGH LIMIT SWITCH MF MELT ...

Page 31: ...6 ARE 10 AWG WIRES 7 TO 18 ARE 10 AWG FOR 208 240 VOLT UNITS AND 12 AWG FOR 480 VOLT UNITS 3 ALL OTHER WIRES ARE 18 AWG 4 THIS DIAGRAM SHOWS 240 VAC SUPPLY VOLTAGE FOR THE PRIMARY SIDE OF THE TRANSFORMER FOR THE BASKET LIFT POWER SUPPLY BOX WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GY GRAY GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER ...

Page 32: ...CORD APPLIES ONLY TO UNITS WITH FILTER 2 WIRES 1 TO 6 ARE 10 AWG WIRES 7 TO 18 ARE 10 AWG FOR 208 240 VOLT UNITS AND 12 AWG FOR 480 VOLT UNITS 3 ALL OTHER WIRES ARE 18 AWG 4 THIS DIAGRAM SHOWS 240 VAC SUPPLY VOLTAGE FOR THE PRIMARY SIDE OF THE TRANSFORMER FOR THE BASKET LIFT POWER SUPPLY BOX WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GY GRAY GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT C...

Page 33: ... 10 AWG FOR 208 240 VOLT UNITS AND 12 AWG FOR 480 VOLT UNITS 2 ALL OTHER WIRES ARE 18 AWG 3 THIS DIAGRAM SHOWS 240 VAC SUPPLY VOLTAGE FOR THE PRIMARY SIDE OF THE TRANSFORMER FOR THE BASKET LIFT POWER SUPPLY BOX WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GY GRAY GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER DISTRIBUTION BLOCK FM FAT MELT...

Page 34: ...ORD APPLIES ONLY TO UNITS WITH FILTER 2 WIRES 1 TO 8 ARE 10 AWG WIRES 9 TO 24 ARE 10 AWG FOR 208 240 VOLT UNITS AND 12 AWG FOR 480 VOLT UNITS 3 ALL OTHER WIRES ARE 18 AWG 4 THIS DIAGRAM SHOWS 240 VAC SUPPLY VOLTAGE FOR THE PRIMARY SIDE OF THE TRANSFORMER FOR THE BASKET LIFT POWER SUPPLY BOX WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GY GRAY GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CO...

Page 35: ...T TIMER SWITCH GRD GROUNDING LUG HL HIGH LIMIT SWITCH MF MELT FRY SWITCH OMT OVER MAX TEMP LIGHT RED P POWER SWITCH R RELAY 24VAC RDS REAR DRAIN VALVE SWITCH RTC READY TO COOK LIGHT GREEN TH THERMOSTAT TR TRANSFORMER WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GY GRAY GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER DISTRIBUTION BLOCK FM FA...

Page 36: ...FILTER 2 WIRES 1 TO 6 ARE 10 AWG WIRES 7 TO 18 ARE 10 AWG FOR 208 240 VOLT UNITS AND 12 AWG FOR 480 VOLT UNITS 3 ALL OTHER WIRES ARE 18 AWG WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GY GRAY GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER CR CONTACTOR 24VAC DB POWER DISTRIBUTION BLOCK FM FAT MELT TIMER SWITCH GRD GROUNDING LUG HL HIGH LIMIT SWITCH MF MELT FRY SWITCH...

Page 37: ... AWG FOR 208 240 VOLT UNITS AND 12 AWG FOR 480 VOLT UNITS 3 ALL OTHER WIRES ARE 18 AWG WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GY GRAY GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER CPU COMPUTER CR CONTACTOR 24VAC DB POWER DISTRIBUTION BLOCK GRD GROUNDING LUG HL HIGH LIMIT SWITCH OMT OVER MAX TEMP LIGHT RED P POWER SWITCH Rac RELAY 24VAC Rdc RELAY 24VDC RDS REAR...

Page 38: ... 6 68 89 68 129 220 30 0 72 95 72 136 240 35 7 79 103 79 149 480 35 7 39 52 39 74 3 ELEMENTS 6000W EACH 5 ELEMENTS 6000W EACH 10x11 BB 18 20 BB 34x24 BB KEATING FRYER SPECIFICATIONS BB MODELS 3 ELEMENTS 4350W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 11 7 33 33 33 56 220 13 1 34 34 34 59 240 15 5 37 37 37 65 480 15 5 19 19 19 32 VOLTS kW AMPS PER LINE THREE PHASE L1 L2...

Page 39: ...PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 32 2 89 89 89 155 220 36 0 95 95 95 164 240 42 8 103 103 103 179 480 42 8 52 52 52 89 4 ELEMENTS 6000W EACH 6 ELEMENTS 6000W EACH 10x11 TS 18 20 TS 34x24 TS TS MODELS 3 ELEMENTS 6500W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 17 4 48 48 48 84 220 19 5 51 51 51 89 240 23 2 56 56 56 97 480 23 2 28 28 28 48 VOLTS kW AMPS...

Page 40: ...anty against latent defects Exclusions The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installation or maintenance abuse misuse modification or alteration by unauthorized service personnel or any other condition not attributable to a defect in material or workmanship Proper installation and maintenance ar...

Page 41: ...RRANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE Have your serial and model number available when ordering parts As continuous product improvement occurs specifications may be changed without notice KEATING LIMITED WARRANTY CARD FRYER GRIDDLE CUST...

Reviews: