7
time.
:
Capacity Cut-Off
On 5000mAh
The limitation of the charger capacity, that is the charging will stop once exceed the capacity of
the figure. The limitation can prevent over charging
,
but you should set a proper value according
to actual setting, or maybe the battery won’t be charged fully. For example, to the battery of
5000mAh
,
it only could be cut off when setting it 6000mAh. Because it is the power which
released by the charger, but not the power chargerd. Some power which is not charged into the
battery because of heating or other inside consume, we could set the value to 1.2 times of the
capacity of battery by fast charge.
You could set it Off if you don’t need it
,
and there will be no the limitation for charger capacity.
⑹
save the data /load the data
1.) save the data
The charger will load the data which was loaded last time when you trun on the charger every time.
The data of the new charger is [01]. It is inconvenience that you should set the current and the
voltage when charging. So you need to set a data in common use, and save it. Or you could set
more common use data, and load them directly when you need it.
In the interface of keeping data
:
Program Select
Save Data interface
Press Start / Enter button
,
it will display
:
Save [01] ****
*.*V ****mAh
01 is glittering, that is the mode number you used, pressing Dec.<orInc.>to change the mode
number you like to change.
Press Start / Enter
,
and it will display glittering at the top right corner. You can presse Dec.<or
Inc.> button to change the type of the battery. And then press Start / Enter buton for long.
after changing the type for the battery.
And then you could change the setting of the routine current and voltage. pressing Start / Enter
for long to save the data, display interface
:
Save…
Turn back to the main interface
***the mode of NiMh / NiCd has
:
NiMh Cycle
DCHG>CHG 1
The setting is the circular charge and discharge setting between discharging and charging. It is