6
The display content is the same as the LiPo, the display content after full charge is the same too. It
is full charge when display “FULL”
*** Press Batt. Type / Stop to stop charge during charging at any moment.
***Pree Start / Enterto to change the current during charging at any moment, remember
reconfirming after changing.
*** Press Dec. < or Inc. > to see the parameter during charging at any moment.
2.
)
Discharge
Choose the function of NiMh Discharge
,
interface
:
NiMh Discharge
*.*A *.*V
The operating mothod is the same as charging. It can work after setting the discharge current and
the ending voltage of discharge. The voltage setting of NiMh Discharge is 0.9V/cell
,
so please
setting 7.2V battery to 5.4V
⑶
NiCd Discharge
The same as NiMh Discharge
⑷
LiPo Discharge
The same as NiMh Discharge
⑸
Charger setting
As a common player, you don’t pay attention to generic setting. Such as LiPo testing voltage
、
NiMh and D.Peak, Waste Time, only keep it default
User Set
Press Start / Enter button in the interface
User Set
Program->
LiPo
V.Type *.*V
Set the voltage of LiPo according to the actual change. Choosing LiPo 3.7V
,
LiIo 3.6V
,
LiFe 3.3V
USB/Temp Select
Temp Cut-Off 80C
The Protection for over-heat or using USB to test
This is upgrade function, the charger does not come with temperature detector, USB and CD for
the time being.
Safety Timer
On 120min
This is the automatic cutoff time of charging, the default is open. It will be cut off after charging
120s. it is remcommended to set it to be open., or change the figure accorging to the charging