-22-
When the check is done, depending on the result the screens shown below will be
displayed.
If
it
is
NG,
check
if
the
altitude setting is set correctly in default set mode
(
→
P20). If the cause might be due to moisture, run the “Unloaded Muffle Firing” (
→
P7)
and check one more time. Press the “Back” button to move to maintenance mode.
OK NG
Total
Powered
on
Time
:
It will display the total time the unit has been powered on since
purchasing the unit. The measure is hour.
Total Firing Cycles
:
It will display the total amount of cycles run since purchasing the unit.
Firing
Cycle
Memo
:
It is possible to delete this firing cycle memo. Keep pressing the
“Delete Firing Memo” button for 1 second to clear the firing cycle
memo to 0. When exchangingmuffle, keep record of when to change
the muffle next
.
Then clear the firing cycle memo.
SD Card Mode
・
On SD Card Mode
:
This is to write firing program data(s) from the unit to the SD Card or to read firing
program data(s) from SD Card to the unit. It is possible to edit firing program
data(s) with a computer.
・
How to enter SD Card Mode
:
Press SD Card key to enter "Default Set Mode" (
→
P20) as shown below.
・
How to use each item of SD Card Mode
Writing
program
content
:
Press F2 key to write firing program datas from the unit to SD Card.
The program firing datas are saved as "MPPRG.CSV" about course 0 to
499, “MPRG2.csv” about course 500 to 529.
It is possible to edit the file at a computer with EXCEL etc.
Reading
program
content
:
Press F3 key to read program firing data(s) from the SD Card to the unit
as "MPPRG.CSV" and “MPRG2.CSV”.