To convert the duct connection (top -> bottom), pro-
ceed as follows:
• Loosen the duct connection KBL 3119900006
(4 x M6).
• Remove the upper housing cover KBL 3112200301
(7 x oval head screw 4,2 x 9,5).
• Remove the fan flange KBL 3112200260 (4 x M6).
• Remove the lower cover plate KBL 3112200304 (4
x oval head screw 4,2 x 9,5).
• Remove the lower housing base KBL 3112200239
(7 x oval head screw 4,2 x 9,5).
• Install the fan flange, housing base and duct con-
nection on the lower side.
• Install the upper housing cover KBL 3112200301.
• Install the cover plate KBL 3112200304 on the
upper cover of the housing KBL 3112200301.
COMPONENT OVERVIEW
Duct connection
KBL 3119900006
Housing cover
KBL 3112200301
Fan flange
KBL 3112200260
Housíng base
KBL 3112200239
Fan connection cover plate
KBL 3112200304
INSTALLING THE TOP CROWN ON TANNING
DEVICES WITH CENTRAL EXHAUST AIR MODULE
In principle, installation is the same as described
under “Installing the top crown”.
Additional steps:
• A grate has to be installed on the top crown section
of the door.
4.9.2. INSTALLATION – PREPARATION
10
PH2
• Remove the duct connection. (KBL 3119900006)
10
• Remove the upper housing cover. (KBL
3112200301)
PH2
A s s e m b l y I n s t r u c t i o n s
|
KBL Tower pureEnergy 5.0
17
Summary of Contents for megaSun pureEnergy 5.0
Page 1: ...TANNING DEVICE TANNING DEVICE ASSEMBLY INSTRUCTIONS MENU SETTINGS ...
Page 2: ......
Page 41: ...Remarks A s s e m b l y I n s t r u c t i o n s KBL Tower pureEnergy 5 0 41 ...
Page 42: ...Remarks A s s e m b l y I n s t r u c t i o n s KBL Tower pureEnergy 5 0 42 ...
Page 43: ......
Page 44: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...