Connections
Connecting the mains voltage
DANGER!
Live components
Risk of fatal injury due to electric shock
when touching live parts.
Disconnect from mains
according to DIN
VDE 0105.
Both the power supply and the related connection
work must comply with national standards, e.g. those
set up by VDE in Germany. The connection must only
be performed by qualified expert staff.
The connection to the 400 V mains must be protected
by fuses. Their specifications are listed in the chapter
“Technical data”.
A discriminating residual current-operated circuit
breaker must always be used. KBL-Solarien AG
recommends the following type: KBL 3200 0770 00
(type ABB F 374 63/0.03A). Should the operation of
the tanning unit cause any interference in the power
supply network, e.g. with ripple-control systems
(TRA), consult your power supply company regarding
the installation of corresponding blocking elements
(audio frequency suppressor).
Figure 8.1
������������
����������
����������
���������
���������
�� �� �� �� �
����������������������������������������
������������������������������������
���������������������������������������
������������������������������
����������������
Connecting an external audio
source
When connecting an external audio source, pay
attention to the correct polarity.
Figure 8.2
R-
green
Wiring on the audio equipment’s side
yellow
white
brown
R+ L-
L+
Level adjustment
The voice/audio system components are built
into the base part (in the head area) of the tanning
unit. The total level adjustment is carried out via a
potentiometer (see arrow) that is located on the audio
switch circuit board.
Figure 8.3
Summary of Contents for megaSun 5800
Page 1: ...Manuale operativo ...
Page 27: ...KBL4 service level I page 2 2 M a n u a l e o p e r a t i v o megaSun 5800 27 ...
Page 28: ...KBL4 service level II page 1 2 M a n u a l e o p e r a t i v o megaSun 5800 28 ...
Page 29: ...KBL4 service level II page 2 2 M a n u a l e o p e r a t i v o megaSun 5800 29 ...
Page 59: ...Commento M a n u a l e o p e r a t i v o megaSun 5800 59 ...