FILTER pAD IN ThE cANOpy SEcTION
you can easily replace the filter pad installed on the
rear side of the canopy.
Figure 47.1: Filter pad in the canopy
FILTER pAD IN ThE bASE SEcTION
The filter pad is located behind the decorative lighting
in the base section. Open the bed pane and remove
the fluorescent tube to get access to the filter pad.
Figure 47.2: Filter pad in the base section
Canopy drive
REGuLAR MAINTENANcE
In order to ensure a troublefree operation of the drive,
carry out the maintenance of the ropes after each
tube replacement (see table below, item 1).
TENSIONING ThE SpRINGS
As soon as the canopy of the tanning system does
not remain safely in its upper position any more, the
two springs must be tensioned. To do so, a ratchet
spanner with hexagon socket (10 mm width across flats)
is required.
Procedure
Fig.
1
Check the spring ropes for wear.
Should individual rope wires have
spliced, always replace both ropes.
2
Remove the side pane.
Procedure
Fig.
3
There are tensioning screws on the
right-hand and left-hand side.
47.3
47.4
4
Tension both springs equally.
5
Check the canopy drive: the canopy
stops in all positions.
6
Close the side pane again.
Figure 47.3: Tensioning spring on the left-hand side
Figure 47.4: Tensioning spring on the right-hand side
M a n u a l e o p e r a t i v o
|
megaSun 5800
Summary of Contents for megaSun 5800
Page 1: ...Manuale operativo ...
Page 27: ...KBL4 service level I page 2 2 M a n u a l e o p e r a t i v o megaSun 5800 27 ...
Page 28: ...KBL4 service level II page 1 2 M a n u a l e o p e r a t i v o megaSun 5800 28 ...
Page 29: ...KBL4 service level II page 2 2 M a n u a l e o p e r a t i v o megaSun 5800 29 ...
Page 59: ...Commento M a n u a l e o p e r a t i v o megaSun 5800 59 ...