System messages
ERROR MESSAGES
After the error has been eliminated, all error messages must be acknowledged by pressing
START
on the interior display
.
No.
Status message
Description
Remedy
01
Excess temperature bimetal
canopy
Bimetal switch triggers.
Check the air-intake/air-discharge system. Let the
sunbed cool down.
02
Maximum
tanning time!
Enabling signal from coin-box system
comes in longer than the time value
approved under “Maximum tanning time”
(voltage remains connected)
Disconnect from the coin-box system.
03
Excess temperature exhaust
fan, please check
Bimetal switch in the fan triggers.
Make sure the fan runs freely. Check the air-intake/air-
discharge system. Let the sunbed cool down.
04
Connection
fan
speed
control faulty
Faulty communication between Mainboard
and fan-speed control.
Check / replace the patch cable.
08
Canopy pane open, please
close
Contact of the canopy pane has triggered.
Close the canopy pane and check the contact.
10
Bench / bench pane open,
please close
Contact of the bench pane has triggered.
Close the bench / bench pane and check the contact.
12
KBL7 Hardware error Input-
Controller
Mainboard defective.
Contact your Customer Service.
13
Maximum write cycle fl ash
memory reached
Maximum write cycle fl ash memory
reached.
Contact your Customer Service.
14
Error! SD card read error
(CRC fault)
Update via SD card failed (CRC fault).
SD card check / replace.
15
Error! no access to the SD
card
Update via SD card failed (access error).
SD card check / replace
17
Parameter
storage
not
found, please connect and
restart
Parameter storage not found, please con-
nect and restart.
Check connector parameter storage. If necessary re-
place parameter storage.
18
Parameter storage no valid
serial number
Parameter storage no valid serial number.
Contact your Customer Service.
19
CAN-BUS: Interior display
V1 is incompatible
CAN-BUS operators incompatible.
Use CAN-BUS operaters V2.
20
CAN-BUS: preSelection dis-
play V1 is incompatible
21
CAN-BUS: audio module full
V1 is incompatible
22
CAN-BUS: RGB module V1
ist incompatible
23
Parameter storage write er-
ror
Parameter storage write error.
Check connector parameter storage. If necessary re-
place parameter storage.
24
Parameter storage read error
Parameter storage read error.
Check connector parameter storage. If necessary re-
place parameter storage.
25
Frequency detection: detec-
tion failed!
Frequency detection failed.
Restart the controller. Contact your Customer Service
after the third unsuccessful restart.
26
Frequency detection: power
supply
connection
faulty
(connector X6/E6)!
Frequency detection failed. No mains volt-
age.
Check mainboard connector X6/E6.
O p e r a t i n g I n s t r u c t i o n s
|
megaSun 4800
51
Summary of Contents for MegaSun 4800
Page 1: ...OPERATING INSTRUCTIONS ...
Page 2: ......
Page 57: ...O p e r a t i n g I n s t r u c t i o n s megaSun 4800 57 Remarks ...
Page 58: ...O p e r a t i n g I n s t r u c t i o n s megaSun 4800 58 Remarks ...
Page 59: ......