Ventilation and air-conditioning
↵
In order to preserve the performance of the air-
conditioning unit, clean the heat exchangers after
500 - 600 hours of operation.
㉗
Heat exchanger
㉘
Condensate pump
㉙
Condensate tray
㉗
㉘
㉙
Air-conditioning unit
Page
40
Open the bench part.
㉗
Clean the heat exchanger.
Vacuum it carefully, paying attention not to
damage the fi ns.
SERVICING THE VENTILATION SYSTEM
⇒
Check all hose connections.
⇒
Remove any kinks in the air hoses. Replace
defective hoses immediately.
The exhaust air hose must not exceed a
maximum length of 6 m if there is no auxiliary
fan installed.
CHECKING THE CONDENSATE PUMP
The condensate pump
㉘
pumps away the
condensation water at timer-controlled intervals.
Check the function of this pump with each tube
replacement.
⇒
Fill some water into the condensate tray
㉙
.
Use a hose and a funnel to do so.
Make sure that the water does not spill over.
⇒
Start a tanning session and then wait for 20
minutes.
⇒
The fi lling level of the tray must then be below
the pump level.
O p e r a t i n g I n s t r u c t i o n s
|
megaSun 4800
48