WES CONFIGURATION TABLE 

 
KBC recommends that a spreadsheet of the wireless system be kept on hand for 
reference. A worksheet providing all of the default settings is included in the shipment. 
These settings along with any changes should be kept and tracked in a format similar to 
the example provided below: 
 

S/N 

Device 

Name 

Type 

IP 

Channel & 
Frequency 

GUI 

Password 

08516 

Head End 1 

SP Host 

192.168.1.200  0; 5745 

abcsecurity 

08517 

PTZ Cam 

Client 

192.168.1.201  0; 5745 

abcsecurity 

08518 

Head End 2 

MP Host 

192.168.1.202  7; 5825 

abcsecurity 

08519 

Plate 
Camera 

Client 
Patch 

192.168.1.203  7; 5825 

abcsecurity 

08520 

Front Gate 

Client 

192.168.1.205  7; 5825 

abcsecurity 

 
 
Configurations shown above are not default settings. Information shown only to 
indicate what should be recorded when changes are made to the default settings. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 
 
20 

 

Wireless Ethernet PtP & MP System Operations Manual 

 

WES SPECIFICATIONS 

For product improvement, design and specifications are subject to change without notice. 
 

RF MODULES 

 

Power Output 

 

50 W EIRP @ 5.8 GHz (maximum) 

Transmitting Frequency 

5725 – 5825 MHz (U-NII-3 ISM) 

Channel Capacity  

5 non-overlapping channels 

 

 

 

5745, 5765,5785, 5805, 5825 MHz 

Modulation 

 

OFDM 

Latency   

 

<10 milliseconds 

Sensitivity 

 

-82 dBm fir maximum data rate 

Polarization 

 

Linear, vertical only 

Antenna Type & Gain 

Omni (WAPOM, WSUOM): 2.5 dBi @ 5.8 GHz 

 

 

 

Small patch (WES-2500; WAP, WSU): 7.8 dBi @ 5.8 GHz 

 

 

 

Large patch (WES-2-4; WSUP): 16.7 dBi @ 5.8 GHz 

 

 

 

Small patch in 18 inch parabolic dish: 24 dBi @ 5.8 GHz 

Beam Width 

 

Omni: 360

; Small Patch: 90

; Large Patch: 24

; Dish: 8

 

Data Throughput Rate 

Up to 20 Mbps, Standard Mode; Up to 50+ Mbps, Super 
Mode 

FCC ID 

JRRWES 

IC 

4887A-WES 

 

MANAGEMENT 
Interface 

10/100 Base T, half/full duplex, rate auto-negotiated (802.3 
compliant) 

Frequency Selection 

Physical: 8-position rotary switch; Software: pull down and 
select manual switch override capability (see pages 14-15) 

Web browser GUI 

Password protected internal web browser interface 
configuration pages. Compatible with Internet Explorer and 
Mozilla Firefox.  

Access Method 

Time division duplexing/Time division multiple access 
(TDD/TDMA) 

Protocols Used 

IPV4, UDP, TCP, ICMP, Telnet. HTTP. FTP, SNMP. Network 
management: http 

 

MECHANICAL 
Physical 

Environmentally protected, billet aluminum, powder coated 
housing with UV stabilized PVC radome 

Dimensions 

(WES-2500 individual modules; WAP, WSU): 92.68 mm x 
44.55 mm x 91.69 mm; (WES-2-4 individual modules, 
WSUP): 170.48 mm x 54.55 mm x 170.48 mm; (WAPOM, 
WSUOM): 91.61 mm x 91.68 x 50.26 mm 

Weight 

(WES-2500 individual modules, WAP, WSU): 0.4 Kg; (WES-
2-4 individual modules, WSUP): 0.7 Kg; (WAPOM, WSUOM): 
0.4 Kg 

 

POWER 
Power Requirements 

12-20 VDC @ 3 W (Reverse voltage protected 

Power Method 

Power over Ethernet, mid-span compliant via power injection 
module (PIM) 

Connector 

 

RJ-45, in & out of PIM as well as into LAN port of WEM 

Cable Specifications 

100 meters max, 24 AWG Cat5e recommended 

 
21 

Summary of Contents for WAP

Page 1: ...297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA Carlton Suite Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Office 44 0 1622 418782 Fax 44 0 20 7100 8147 Email info kbcnetworks com Web www kbcnetworks com Wireless Ethernet Point to Point Multipoint Systems Operations Manual Version 20111027 ...

Page 2: ...odule WAP WAPOM or subscriber unit WSU WSUP WSUDI WSUOM Qty 1 PIM Qty 1 PS 500 A Qty 1 LNBMB excluded in WAPOM or WSUOM Qty 1 Strain Relief for Ethernet cable connection at RJ 45 LAN port of WES module Qty 1 Operations manual P 1 Wireless Ethernet PtP MP System Operations Manual PREFACE CONTINUED TECHNICAL SUPPORT AVAILABILITY This manual is comprehensive to the extent that it will answer many of ...

Page 3: ...ANT SAFETY INSTRUCTION For your protection please read and observe all safety instructions before operating this system and keep this sheet and any additional instructions for future reference INSTALLATION USE OBSERVE WARNINGS All warnings in the operating instructions should be carefully followed Do not make any modifications to the Wireless Ethernet Module WEM Power Injection Module PIM or any o...

Page 4: ...it not expressly approved by the party responsible for compliance could void the users authority to operate the equipment Changes or modifications not expressly approved by KBC could void the users authority to operate the equipment iii Wireless Ethernet PtP MP System Operations Manual FCC POWER OUTPUT RESTRICTIONS The FCC does not require licensing to implement this device License free operation ...

Page 5: ...otherwise noted The channels of each set of Host Clients must be matched for the radios to communicate with each other For multi connect devices each Client must be set to the same channel as the Host that it will be connected to If connecting more than one Client to a single Host please see the advanced operation section of this manual for multipoint setup 2 Mount the Client at the remote locatio...

Page 6: ...y of IP cameras DVR NVRs managed non managed switches encoders decoders and web servers to be used across long range wireless line of sight links A FRONT VIEW 1 Module case 2 Antenna cover B REAR VIEW 1 Serial Number 2 List of Available Frequencies 3 Channel Selector on side of WEM Factory set to channel 0 unless otherwise noted 4 Status LEDs Amber Link Activity Red Power Green Signal Level 5 LAN ...

Page 7: ...LED responses determined by the type of product in use POINT TO POINT HOST LED ACTIVITY WES 2500 WES 2 4 Hosts If the green LED flashes at any rate it is indicating a less than max signal connection MULTIPOINT HOST LED ACTIVITY WAP WAPOM CLIENT LED ACTIVITY All Clients from all part numbers excluding WAP WAPOM The Client LED status will remain the same regardless of the type of host to which it is...

Page 8: ...diagram to the left 3 Power cycle device to implement channel change 4 Reseal port by replacing weatherproof plug B MOUNT DIRECTIONAL HOST CLIENT Mount the Host Client using the included wall pole mount bracket and hardware Connect the black mounting assembly with adjustment swivel to mounting L shaped bracket with the 20 button head screw Connect the unit to the mounting assembly using the mounti...

Page 9: ...ending on the physical and RF environment a useable throughput rate may not be possible Contact KBC for more information 888 366 4276 or info kbcnetworks com 8 Wireless Ethernet PtP MP System Operations Manual ADVANCED OPERATION WEB BROWSER INTERFACE Each Host and Client has a web browser interface to access the advanced setup functions If changing advanced settings be sure to connect and power th...

Page 10: ..._____ Subnet Mask The filter used for association of Ethernet devices _________ WIRELESS MAC Address The MAC address of the radio Record this information for tracking purpose __________________________________ Current Trans Rate The Client will display its signal rate to the Host Max is 54 _ Current Frequency Client Current frequency scanned for AP________________ Turbo Mode Available on 5765 5805...

Page 11: ...ped or collided packets As the system continues to run these numbers will accumulate until cleared to 0 Refresh to see updated statistics ETHERNET STATISTICS Packet information at the motherboard and cable level If packets are dropped or collided at the Ethernet level then there could be a problem with the cabling or other LAN related hardware WIRELESS STATISTICS Packet information across the wire...

Page 12: ...EL SWITCH OVERRIDE A drop down list of frequencies will appear Make sure that if changing frequencies using a connected wireless link the channel on the opposite end is configured first For units with the 25 5 dBi jumper ON selecting 5280 5300 or 5320 will default to 5745 as only 5745 5825 is available 2 Wireless Security Mode The WES can be configured to various forms of wireless encryption and c...

Page 13: ...vice name for the Host and or Client ADMIN PASSWORD To change the password type in the desired password change and confirm Record all password changes as there are no ways to reset to default later if the password is lost or forgotten ADMINISTRATION The device name can be changed here Each unit does not have to have a matching device name in order to associate This name will appear on the status i...

Page 14: ...itch Super Mode Disabled Encryption Cipher WPA 2 AES Device Name WES SP Host WES MP Host WES Client depends on software type 18 Wireless Ethernet PtP MP System Operations Manual ADVANCED OPERATION CONTINUED H ADVANCED FIRMWARE This page is used to flash firmware updates when necessary FIRMWARE INFORMATION Current firmware is 7 06 for all units using channel selector switches that have 8 positions ...

Page 15: ...ni WAPOM WSUOM 2 5 dBi 5 8 GHz Small patch WES 2500 WAP WSU 7 8 dBi 5 8 GHz Large patch WES 2 4 WSUP 16 7 dBi 5 8 GHz Small patch in 18 inch parabolic dish 24 dBi 5 8 GHz Beam Width Omni 360 Small Patch 90 Large Patch 24 Dish 8 Data Throughput Rate Up to 20 Mbps Standard Mode Up to 50 Mbps Super Mode FCC ID JRRWES IC 4887A WES MANAGEMENT Interface 10 100 Base T half full duplex rate auto negotiate...

Page 16: ... WEMs are aimed properly You should have clear wide open line of sight between the WEM modules Try a different frequency and cycle power Verify sufficient voltage into each PIM If MP Host the green LED should flash see page 5 Problem Suggestion All three solid LEDs but no video Check video at the camera Check wiring into encoders or decoders Try a different frequency and cycle power Connect one WE...

Page 17: ...n implied warranty lasts so the above exclusions or limitations may not apply to you f If you do not wish to be bound by any of the provisions in this warranty please return the product s immediately 3 Contact your dealer regarding return authorizations for out of warranty repairs and any further product information 24 Wireless Ethernet PtP MP System Operations Manual APPENDIX The appendix section...

Page 18: ... Address Remote Location 2 Head End Location in Single Point to Point Application Device S N Host Client IP Address Radio MAC Address Remote Location 3 Device S N Host Client IP Address Radio MAC Address Remote Location 4 Device S N Host Client IP Address Radio MAC Address Head End Location Device S N Host Client IP Address Radio MAC Address A 2 ...

Reviews: