background image

1

ON

1  2

ON

1  2

XRF-RD

ON

1  2

23

99

94

91

91

23

Dual channel receiver to XRF wireless transmission system

Original operating instructions

Intended use: Monitoring safety edges and switches on industrial doors and gates

Safety instructions

2

2

Common applications

ENGLISH

404168B

12/20

XRF-RD

XRF-RD.A (with antenna)

Receiver 

Figure 

1.a

Receiver 

Transmitter

Door

switch

Figure 

1.b 

Tx1

Tx2

Receiver

Output 

1

Output 

1

Output 

2

Output 

2

Transmitter 

input 1

 corresponds to receiver

 output 1

Transmitter 

input 2

 corresponds to receiver 

output 2

Transmitter Tx1

 (input 1) corresponds to receiver 

output 1

Transmitter Tx2 

(input 1) corresponds to receiver 

output 2

   Terminals   

0.08 – 2.5 mm

2

  LED SYS

  LCD display

 Joystick

1

•  Read these operating instructions thoroughly before putting the device into 

operation and keep them for future reference.

•  Do not use this product other than for its specified application.

•  Only trained and qualified personnel may install and initialize the device.

•  Only authorized factory personnel may perform hardware/software changes or 

repairs to the product. 

•  Failure to follow these safety precautions may cause damage to sensor or objects, 

serious personal injury, or death. 

•  It is the responsibility of the equipment manufacturer to carry out a risk assess-

ment and to install the system in compliance with applicable local, national and 

international regulations, safety standards, codes and laws as well as the 

Machinery Directive 2006/42/EC, should this apply.

•  Always consider the safety functions of your applications as a whole, never just in 

relation to one individual section of the system.

•  The installer is responsible for testing the system to ensure it meets all applicable 

safety standards.

•  Safety devices that are classified as Category 2 according to EN ISO 13849-1 must 

be tested regularly – at least once per cycle.

•  If the safety device is not requested operationally at least once a year, it must be 

checked manually by the operator at least once a year.

•  During the operation of electrical components  

–  e. g. in the case of a short circuit, hot and ionised gases can be emitted; 

protection covers must not be removed!

•  The sensor should only be operated from a safety extra low voltage (SELV) system 

with safe electrical separation according to EN 61558. The wiring must be 

protected against mechanical damage.

•  Check the voltage data on the label of the switching device. 

•  Pay attention to all local relevant electrical safety regulations.

•  Ensure that the device/installations cannot be switched on.

• Ensure that the power supply is disconnected.

•  Protect the device with a housing against contamination or harsh environments.

•  Disconnect device from mains in the event of a fault. 

•  After accessing the inside of the device, ensure the cover/protection seal is closed 

tightly to achieve the designated protection rating.

Max.14 transmitters in this configuration

Max.7 transmitters in this configuration

Summary of Contents for XRF-RD

Page 1: ...ternational regulations safety standards codes and laws as well as the Machinery Directive 2006 42 EC should this apply Always consider the safety functions of your applications as a whole never just in relation to one individual section of the system The installer is responsible for testing the system to ensure it meets all applicable safety standards Safety devices that are classified as Categor...

Page 2: ...r Receiver Receiver Receiver Receiver Receiver Transmitter Tx1 Transmitter Tx2 Transmitter s Release button Release button Release button Pair to output 1 Pair to output 2 Pair to both outputs Long press joystick Move joystick left Move joystick right Move joystick upwards Move joystick acc to requested configuration see 7 2 LED LED LED LED LED LED LED LED Flashes orange Orange Orange Orange Flash...

Page 3: ...ing edge orange 2 8k2 CLOSED CLOSED open open Stationary sensor 1 pressed output 1 orange 1 CLOSED open 8k2 CLOSED open Stationary sensor 2 pressed output 2 orange 2 8k2 CLOSED CLOSED open open Wicket door open XRF TW on channel 2 orange 2 8k2 CLOSED CLOSED open open Configuration a Pairing b BSI c Stationary edges d Test Input orange flashing 2 1 a 2 1 b 2 1 c 1 2 d CLOSED open CLOSED open open u...

Page 4: ... supported sensors max 14 stationary sensors included Mounting DIN rail Protection class IEC 60529 IP20 System Operating frequency 868 3 MHz Reaction time Typ 15 ms Range 60 m at optimal condition According to EN ISO 13849 1 PLd for Cat 3 applications test input for Cat 2 applications Operating temperature 20 C to 60 C Beep Beep Beep See attachment 11 WEEE Devices with this symbol must be treated ...

Reviews: