background image

 

WES Mesh Wireless System Operations Manual 

 

IMPORTANT SAFETY INSTRUCTION 

 

For your protection, please read and observe all safety instructions before operating 
this system and keep this sheet and any additional instructions for future reference. 

INSTALLATION & USE 

OBSERVE WARNINGS:  All warnings in the operating instructions should be carefully 
followed. Do not make any modifications to the Mesh node, Power Injector Module 
(PIM), or any other KBC electronic device, as the unit(s) will no longer comply with 
FCC regulations and therefore cancel its warranty. 

WATER AND MOISTURE:  The Mesh nodes are weatherproof provided they are 
installed in accordance to the mounting details listed on page 7.  However, further 
protection or housing is suggested for harsh environments, as moisture damage 
voids its warranty. The Power Injection Modules used in this system are NOT 
weatherproof.  None of the modules in this system are waterproof and should never 
be submerged.  Severe electrical shock, personal injury or damage to the equipment 
may result. 

POWER SOURCE:  Connect the equipment to a power source only of the type 
described on the operating instructions or as marked on the equipment. Excessive 
or insufficient amperage or voltage can cause extended trouble-shooting or even 
damage that could negate its warranty. The power supplies’ cable should not be 
modified/extended due to the ability to send power over Ethernet using the PIM. In 
addition, Ethernet cable running from the PIM to the Mesh Node should be kept 
separated from high-voltage cables and/or transformers. 

ATTACHMENTS:  Use only KBC supplied or recommended Power Injection Modules, 
Power Supplies, Cat5 Cables and weather seals and plugs. 

WHEN NOT IN USE:  Unplug the power if the equipment is left unattended or unused 
for long periods of time or during lightning storms. 

REPLACEMENT PARTS:  When replacement parts are required, use only replacement 
parts specified by KBC. Unauthorized substitutions may result in damage to the 
system and could void the warranty. 

 

 
 

 

 

 
 
 

 
 

 
 

 
 

 

WES Mesh Wireless System Operations Manual 

 

FCC REQUIRED INFORMATION – RADIO FREQUENCY 
INTERFERENCE STATEMENT FOR CLASS A DIGITAL DEVICES 

 

This equipment has been tested and found to comply with the limits for a Class A 
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio frequencies. Operation 
of this equipment in a residential area is likely to cause harmful interference in 
which case the user will be required to correct the interference at his own expense. 
 
This equipment is designed to be professionally installed exclusively for fixed point-
to-point and/or multipoint mesh applications.  These products must be controlled due 
to radio frequency power output levels emitted with special consideration given to 
antenna placement as it relates to human exposure.  Compliance is the responsibility 
of the installer and user. 

 

RADIO FREQUENCY INTERFERENCE STATEMENT 

 
This equipment has been tested and found to comply with the limits for an 
intentional radiator, pursuant to Part 15, Subpart C of the FCC Rules. This 
equipment generates, uses, and can radiate radio frequency energy. If not installed 
and used in accordance with the instructions, it may cause interference to radio 
communications. The limits are designed to provide reasonable protection against 
such interference in a residential situation. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause 
interference to radio or television reception, which can be determined by turning the 
equipment on and off, the user is encouraged to try to correct the interference by 
one or more of the following measures:  

 

Reorient or relocate the receiving antenna of the affected radio or television.  

 

Increase the separation between the equipment and the affected receiver. 

 

Connect the equipment and the affected receiver to power outlets on 
separate circuits. 

 

Consult the dealer or an experienced radio/TV technician for help. 

Shielded cables must be used with this unit to ensure compliance with Class A 
FCC limits. Changes or modifications to this unit not expressly approved by the 
party responsible for compliance could void the users authority to operate the 
equipment. Changes or modifications not expressly approved by KBC could void 
the users authority to operate the equipment. 

 
 
 
 

 

 

 

 

 

 

 

ii 

 

Summary of Contents for MESH-AA-Ox

Page 1: ...Main 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA Carlton Suite Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Office 44 0 1622 418782 Fax 44 0 20 7100 8147 Email info kbcnetwo...

Page 2: ...perations manual P 1 WES Mesh Wireless System Operations Manual PREFACE CONTINUED TECHNICAL SUPPORT AVAILABILITY This manual is comprehensive to the extent that it will answer many of your technical q...

Page 3: ...Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envir...

Page 4: ...pliance with the applicable sections of the Industry Canada RSS 210 Spectrum Management and Telecommunications Radio Standard Specification that governs Low Power License Exempt Radio communication De...

Page 5: ...right is the secondary antenna port Some nodes may have other antenna options 3 Connect a standard Cat5 straight through patch cable from the open RJ 45 Ethernet port on the Node to the P Data RJ 45...

Page 6: ...thirty 30 days of shipment provided the products are in like new condition and in the original packaging Contact your KBC dealer or distributor to obtain an authorization to return the merchandise for...

Page 7: ...O A KBC ENCODER OR DECODER CONNECTING TO AN ETHERNET 10 100 1000 SWITCH Type of Ethernet cable is determined by the Ethernet device LAN port If the LAN port is a 10 100 port then the cable will be a c...

Page 8: ...selected using the RSSI and rate figures as described on page 12 of this manual In some environments additional nodes may be necessary to reduce the number of hops while enabling redundant paths 7 WE...

Page 9: ...cases depending on the physical and RF environment a useable throughput rate may not be possible Contact KBC for more information 888 366 4276 or info kbcnetworks com 9 WES Mesh Wireless System Operat...

Page 10: ...11 WES Mesh Wireless System Operations Manual ADVANCED OPERATION CONTINUED NETWORK TOOLS In addition to using the Microsoft Command Prompt the user can also use the Mesh web browser to ping the other...

Page 11: ...lightly to see the change on the color coded bar on the tool The low weak signals are red and orange etc while the strong connections are green and blue colors 13 WES Mesh Wireless System Operations M...

Page 12: ...for the WiFi 0 radio See Set Up page Power Shows the selected power output for the WiFi 0 radio See Set Up page Rate RSSI Snapshot of the connection rate and signal strength Noise Floor Inbound Packe...

Page 13: ...x subnet Since this interface belongs to the 192 168 1 10 node the 1 11 node must be accessible through a switch Other routes can be added and the gateway route can also be listed under the Default R...

Page 14: ...efaults prior to firmware updates however the previous settings will remain if not restored Select the Country Region Regulatory Domain to use the nodes under the allowable parameters in each country...

Page 15: ...AP should also be included in the spreadsheet 21 WES Mesh Wireless System Operations Manual MESH PRODUCT SPECIFICATIONS For product improvement design and specifications are subject to change without...

Page 16: ...Hardware Pole Bracket and U bolts POWER Power Requirements 7VDC 20VDC Power Method Power over Ethernet PoE via power injector module mid span compliant pins 4 5 positive pins 7 8 ground Connector RJ45...

Page 17: ...h Wireless System Operations Manual WARRANTY INFORMATION KBC extends the following LIMITED WARRANTY to the original owner purchaser of this product as follows Two years from the date of initial sale f...

Page 18: ...radiation pattern in horizontal polarity for 2 4 5 GHz The circles on the left indicate the radiation pattern for 2400 MHz whereas the right side circles show the various 5 GHz band frequencies Each...

Page 19: ...to 54 Mbps 802 11a Turbo 5 GHz frequencies that combine throughput from adjacent frequencies in order to provide additional throughput Fresnel Zone The three dimensional conceptualization of the anten...

Reviews: