background image

 

WES Mesh Wireless System Operations Manual 

 

TROUBLE-SHOOTING 

 

Problem 

Suggestion 

IP address of the 
directly connected 
node will not reply 
to ping response 

- Verify correct static subnet setting on connected laptop/PC 
- Verify correct type of cable needed between laptop/PC and 
“Data In” of the PIM. Crossover cable may be necessary if the 
LAN port of the computer is 10/100. If gigabit connection then 
straight-through should be used. 
- Verify power to the PIM 

 
Problem 

Suggestion 

IP address of the 
wirelessly 
connected node will 
not reply to ping 
response 

- Verify correct static subnet setting on connected laptop/PC 
- Verify gateway setting of the laptop/PC matches the LAN IP of 
the directly connected Mesh node. 
- Verify a ping reply from the directly connected node 
- Ping the node from the GUI interface of the cable connected 
node. 
- Verify correct type of cable needed between laptop/PC and 
“Data In” of the PIM. Crossover cable may be necessary if the 
LAN port of the computer is 10/100. If gigabit connection then 
straight-through should be used. 
- Check advanced routing (page 17 of this manual) 
- Check rate and RSSIs listed under “Mesh Stations” on the 
Network page (see page 12) 
- Verify power to the PIM 

 
Problem 

Suggestion 

No access to the 
GUI via the 
provided IP address 

- IP address should be preceded by “https://” (i.e, 

https://192.168.1.10

- Ping the IP using Command Prompt from your laptop/PC 

 
Problem 

Suggestion 

Video drops in and 
out; recovers on its 
own 

- Weak signal strength (check rate and RSSI from “Mesh 
Stations” on Network page in the Mesh GUI interface. 
- Align directional antennas using the tool or RSSI figures 

 
Problem 

Suggestion 

Low RSSIs (signal 
strengths) 

- Try another frequency 
- Make sure clear line-of-sight to intended radio 
- If omni-directional antennas, try directional antennas. 
- If directional antennas, align the antennas. Make sure 
alignment is done in an “up/down” & “left-to-right” format in 
very small increments. Align up or down until the strongest RSSI 
(KBC recommends at least a 20 or above number for RSSI). 
Then tighten the mounting. Then move left/right. 
- Align using the alignment tool. Make sure other nodes are 
turned off (except intended connected node) 

 

Further assistance is available by contacting KBC at 888-366-4276 Monday-Friday 8am-
5pm Pacific Time for technical support. Or anytime via 

[email protected]

 

E-mails are followed up before the end of the following regular business hours. 
25 

 

WES Mesh Wireless System Operations Manual 

 

WARRANTY INFORMATION 

 
KBC extends the following LIMITED WARRANTY to the original owner/purchaser of this 
product as follows: 

-

 

Two years from the date of initial sale for all wireless and network products. 

-

 

Five years from the date of initial sale for all fiber products. 

1)

 

If, within the specified warranty period, this product, or any part or portion thereof, 
shall prove upon examination by KBC, to be defective in material or workmanship, 
KBC will repair or replace such part or portion at KBC’s option.  The warranty 
period on the repaired or replaced part or portion of this product shall be limited to 
the unexpired term of the original warranty.  The buyer shall be responsible for all 
shipping and transportation of the product to KBC for any performance under this 
warranty. 

2)

 

Conditions and Exceptions: 
a)

 

Any accident to this product, any misuse or abuse, alternation, use in modified 
form, or any attempt to repair this product shall void this warranty.  These 
conditions to the warranty include, but are not limited to, incorrect power 
connections, physical damage due to mechanical shock, exposure to moisture, 
and circuit modification. 

b)

 

SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE, THE 
BUYER, NOT THE MANUFACTURER, DISTRIBUTOR, OR RETAILER, ASSUMES 
THE ENTIRE COST OF ALL SERVICING OR REPAIR, EXCEPT AS OTHERWISE 
PROVIDED BY THE TERMS OF THIS WARRANTY. 

c)

 

FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY ON THIS PRODUCT, 
THE BUYER IS LIMITED TO THE FOLLOWING DAMAGES. (1) THE COST OF 
LABOR TO REPAIR OR REPLACE DEFECTIVE PARTS OR PORTIONS OF THIS 
PRODUCT, AND (2) THE COST OF THE REPAIRED OR REPLACE PARTS OR 
PORTIONS OF THIS PRODUCT. 

d)

 

NO OTHER EXPRESSED OR IMPLIED WARRANTIES HAVE BEEN MADE OR WILL 
BE MADE ON BEHALF OF KBC WITH RESPECT TO THE SALE, REPAIR, 
INSTALLATION, OPERATION, OR REPLACEMENT OF THIS PRODUCT.  KBC 
DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OF THIS 
PRODUCT OR ITS FITNESS FOR ANY PURPOSE, AND THE BUYER AGREES THAT 
THIS PRODUCT IS SOLD “AS IS” AND THAT THE ENTIRE RISK OF QUALITY 
AND PERFORMANCE OF THIS PRODUCT IS WITH THE BUYER, EXCEPT AS 
OTHERWISE PROVIDED BY THE TERMS OF THIS WARRANTY. 

e)

 

Some states/jurisdictions do not allow exclusions or limitations of incidental or 
consequential damages, or limitations on how long an implied warranty lasts, 
so the above exclusions or limitations may not apply to you. 

f)

 

If you do not wish to be bound by any of the provisions in this 

warranty, please return the product(s) immediately. 
3)

 

Contact your dealer regarding return authorizations for out of 

warranty repairs and     any further product information. 

 
 

 

 

 

 

 

 

 

26 

Summary of Contents for MESH-AA-Ox

Page 1: ...Main 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA Carlton Suite Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Office 44 0 1622 418782 Fax 44 0 20 7100 8147 Email info kbcnetwo...

Page 2: ...perations manual P 1 WES Mesh Wireless System Operations Manual PREFACE CONTINUED TECHNICAL SUPPORT AVAILABILITY This manual is comprehensive to the extent that it will answer many of your technical q...

Page 3: ...Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envir...

Page 4: ...pliance with the applicable sections of the Industry Canada RSS 210 Spectrum Management and Telecommunications Radio Standard Specification that governs Low Power License Exempt Radio communication De...

Page 5: ...right is the secondary antenna port Some nodes may have other antenna options 3 Connect a standard Cat5 straight through patch cable from the open RJ 45 Ethernet port on the Node to the P Data RJ 45...

Page 6: ...thirty 30 days of shipment provided the products are in like new condition and in the original packaging Contact your KBC dealer or distributor to obtain an authorization to return the merchandise for...

Page 7: ...O A KBC ENCODER OR DECODER CONNECTING TO AN ETHERNET 10 100 1000 SWITCH Type of Ethernet cable is determined by the Ethernet device LAN port If the LAN port is a 10 100 port then the cable will be a c...

Page 8: ...selected using the RSSI and rate figures as described on page 12 of this manual In some environments additional nodes may be necessary to reduce the number of hops while enabling redundant paths 7 WE...

Page 9: ...cases depending on the physical and RF environment a useable throughput rate may not be possible Contact KBC for more information 888 366 4276 or info kbcnetworks com 9 WES Mesh Wireless System Operat...

Page 10: ...11 WES Mesh Wireless System Operations Manual ADVANCED OPERATION CONTINUED NETWORK TOOLS In addition to using the Microsoft Command Prompt the user can also use the Mesh web browser to ping the other...

Page 11: ...lightly to see the change on the color coded bar on the tool The low weak signals are red and orange etc while the strong connections are green and blue colors 13 WES Mesh Wireless System Operations M...

Page 12: ...for the WiFi 0 radio See Set Up page Power Shows the selected power output for the WiFi 0 radio See Set Up page Rate RSSI Snapshot of the connection rate and signal strength Noise Floor Inbound Packe...

Page 13: ...x subnet Since this interface belongs to the 192 168 1 10 node the 1 11 node must be accessible through a switch Other routes can be added and the gateway route can also be listed under the Default R...

Page 14: ...efaults prior to firmware updates however the previous settings will remain if not restored Select the Country Region Regulatory Domain to use the nodes under the allowable parameters in each country...

Page 15: ...AP should also be included in the spreadsheet 21 WES Mesh Wireless System Operations Manual MESH PRODUCT SPECIFICATIONS For product improvement design and specifications are subject to change without...

Page 16: ...Hardware Pole Bracket and U bolts POWER Power Requirements 7VDC 20VDC Power Method Power over Ethernet PoE via power injector module mid span compliant pins 4 5 positive pins 7 8 ground Connector RJ45...

Page 17: ...h Wireless System Operations Manual WARRANTY INFORMATION KBC extends the following LIMITED WARRANTY to the original owner purchaser of this product as follows Two years from the date of initial sale f...

Page 18: ...radiation pattern in horizontal polarity for 2 4 5 GHz The circles on the left indicate the radiation pattern for 2400 MHz whereas the right side circles show the various 5 GHz band frequencies Each...

Page 19: ...to 54 Mbps 802 11a Turbo 5 GHz frequencies that combine throughput from adjacent frequencies in order to provide additional throughput Fresnel Zone The three dimensional conceptualization of the anten...

Reviews: