Ethernet Switch User Manual 

 

 

 

ESUL6-FL2_inst_manual-Rev 1009 
Copyright © KBC Networks Ltd. 

 Page 5 of 20 

www.kbcnetworks.com 

1.2

 

 Technical Specification  

 

ESUL6-FL2 

Switching 

 

Mode 

Store-and-forward 

Switching rate 

148810pps 

Max filtering rate 

148810pps 

System switching bandwidth 

1Gbps 

MAC address table 

2k 

 

Ports 

 

Copper 

 

Physical port 

6 x shielded RJ45 

RJ45 port 

10/100Base-T/TX 

 

Auto-negotiation 

Standard 

IEEE 802.3 

Transmission distance 

<100m 

Fiber 

 

Optical power 

>-20dBm(MM) >-13dBm(SM) 

Receive sensitivity 

<-35dBm(MM) <-28dBm(SM) 

Wavelength 

1310nm(MM) 1310nm(SM)  

Transmission distance 

0-5km(MM)    0-40km(SM)  

Connector 

SC 

Transmission rate 

125 Mbps 

 

Electromagnetic compatibility 

 

Interference 

EN55022 – Class A 

Immunity 

EN61000-6-2 

 

Power 

 

Input voltage 

24Vdc (18V -36V dc)  

Input power consumption 

<6W 

Over-current protection 

Built in 

 

Environmental 

 

Operating temperature 

40°C - 85°C 

Storage temperature 

40°C - 85°C 

Relative humidity  

0% - 95% 
Non-condensing 

Mean Time Between Failure 

>300,000 hours 

 

 

 

Summary of Contents for ESUL6-FL2-M2

Page 1: ...Ethernet Switch Hardware User Manual ESUL6 FL2 M2 ESUL6 FL2 S2 ...

Page 2: ...2 2 CONFIGURATIONS 6 2 2 1 Physical Connections 7 2 3 INSTALLATION METHOD 8 2 3 1 DIN Rail Mount 8 2 3 2 Wall mount 8 2 4 ETHERNET RJ45 CONNECTIONS 8 2 5 FIBER OPTIC CONNECTIONS 9 2 6 GROUNDING EARTHING 10 2 7 DIP SWITCH SETTING 10 2 8 LED STATUS 11 2 9 POWER INPUT TERMINALS 12 2 10 ALARM RELAY OUTPUT 12 3 TROUBLESHOOTING 13 3 1 SELF TESTING 13 3 2 TWISTED PAIR PORT TESTING 13 3 3 FIBER PORT TESTI...

Page 3: ...FOR RELEASE Ethernet Switch User Manual ESUL6 FL2_inst_manual Rev 1009 Copyright KBC Networks Ltd Page 3 of 20 www kbcnetworks com 7 1 WARRANTY INFORMATION 17 7 2 CLASS A ITE 18 7 3 FCC 18 8 INSTRUCTION OF DISASSEMBLY 19 ...

Page 4: ... Ring technology that recovers cable or port failures automatically in less than 100ms The unit has redundant power supply terminals and an alarm output for power supply and uplink port failure 1 1 1 ESUL6 FL2 The ESUL6 FL2 is an unmanaged switch which provides 6 10 100Base TX twisted pair copper ports and two uplink full duplex multimode or singlemode 100Mbps fiber ports Each copper port supports...

Page 5: ...ase T TX Auto negotiation Standard IEEE 802 3 Transmission distance 100m Fiber Optical power 20dBm MM 13dBm SM Receive sensitivity 35dBm MM 28dBm SM Wavelength 1310nm MM 1310nm SM Transmission distance 0 5km MM 0 40km SM Connector SC Transmission rate 125 Mbps Electromagnetic compatibility Interference EN55022 Class A Immunity EN61000 6 2 Power Input voltage 24Vdc 18V 36V dc Input power consumptio...

Page 6: ...nstallation 2 1 Package Contents Ethernet switch fitted with DIN rail mount 24Vdc PSU terminal block is connected to 24Vdc power lines Wall mount bracket Flat head screwdriver User manual Please contact you dealer or distributor if a part is missing or damaged 2 2 Configurations Products are available in either DIN rail or wall mount packages with the following configurations Product Type DIN DIN ...

Page 7: ...DRAFT VERSION NOT FOR RELEASE Ethernet Switch User Manual ESUL6 FL2_inst_manual Rev 1009 Copyright KBC Networks Ltd Page 7 of 20 www kbcnetworks com 2 2 1 Physical Connections ESUL6 FL2 ...

Page 8: ...e with a Phillips No 1 or No 2 screwdriver Position the unit on the required flat surface and secure with screws via the mounting plate holes Screws are not provided Attach copper and or fiber cables as required Insert the male power block attached to the supplied in line PSU to the female power socket on the device and tighten the terminal locking screws using the flathead screw driver provided S...

Page 9: ...ex SC The interface should be used in a pair Tx and Rx where the Tx interface is the optical transmitting terminal which connects to the optical receiving terminal Rx of the remote device The optical Rx is the receiving terminal which connects to the transmitting terminal Tx of the same optical interface of the remote device The two pairs of uplink redundant fiber ports can be used to form a fiber...

Page 10: ...n 2 5mm2 2 7 DIP Switch Setting The DIP switch settings are used to set either the fiber uplink ports to redundant mode in a ring configuration or straight through not in a ring configuration and if they are in redundant mode then whether they are a master or slave Note In a redundant ring network only one switch can be set as the master and others are set as slaves DIP Switch Position Device Oper...

Page 11: ...h is set as a slave OFF Port 4 8 are set as straight through mode Fiber Port LED ACT ON Effective network connection has been established for the port FLASH Data traffic is passing through the port OFF No effective network connection has been established for the port Ethernet RJ45 Port Status LED Each RJ45 Ethernet port has two indicators a yellow lamp and a green lamp The yellow lamp indicates po...

Page 12: ...upplies to provide redundancy Figure 2 2 Power Input Terminals 2 10Alarm Relay Output The alarm terminal see Figure 2 3 has a relay output Under normal conditions the relay is open if there is a failure of either of the power supplies the terminal relay becomes closed This terminal can be connected to other switching devices lights or alarms to indicate that a power source has been lost The maximu...

Page 13: ... Testing As shown in Figure 3 1 with the switch powered on connect two RJ45 ports from the switch to two test computers and send the ping command between each computer If both the computers receive the complete command without packet loss and the green LED flashes this means that the two RJ45 ports are working correctly Test the other RJ45 ports as required using the same method During normal oper...

Page 14: ...units via their fiber ports Then attach a computer to any RJ45 port on each device and send the ping command between the connected computers If both computers get the command without packet loss and the corresponding ACT indicators of the fiber ports flash this then shows the fiber ports under test are functioning correctly Figure 3 2 Fiber port testing 4 System Example Figure 4 1 ESUL6 FL2 Typica...

Page 15: ...ffers 6 RJ45 10 100Base TX ports each of which can be connected to terminal devices directly or to another industrial Ethernet switch or hub The ESUL6 FL2 also has 2 pairs of uplink 100Base FX fiber ports which can be used to form a redundant optical ring which has a recovery time of less than 100ms A typical redundant ring set up is shown in Figure 5 1 below Figure 5 1 Typical Ring Topology ...

Page 16: ...DRAFT VERSION NOT FOR RELEASE Ethernet Switch User Manual ESUL6 FL2_inst_manual Rev 1009 Copyright KBC Networks Ltd Page 16 of 20 www kbcnetworks com 6 Dimensions mm Wall mount plate ...

Page 17: ...ections physical damage due to mechanical shock exposure to moisture and circuit modification SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE THE BUYER NOT THE MANUFACTURER DISTRIBUTOR OR RETAILER ASSUMES THE ENTIRE COST OF ALL SERVICING OR REPAIR EXCEPT AS OTHERWISE PROVIDED BY THE TERMS OF THIS WARRANTY FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY ON THIS PRODUCT THE BUYER IS LIMITED TO ...

Page 18: ...his equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the...

Page 19: ...ly Instruction of Disassembly of KBC Product For EU Directive 2002 95 EEC WEEE Tools required No 1 Phillips screwdriver No 2 Phillips screwdriver Steps for disassembly 1 Remove tightening screws of box cover 8 screws 2 Remove cover plate 3 Remove tightening screws for printed circuit board PCB 4 Take out all PCBs Notice When a product reaches the end of its life return to KBC ...

Page 20: ...est CA 92630 U S A Americas Phone 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA KBC Networks Ltd Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Phone 44 0 1622 618787 Fax 44 0 20 7100 8147 Email info kbcnetworks com Web www kbcnetworks com data delivered ...

Reviews: