Ethernet Switch User Manual
ESUL6-FL2_inst_manual-Rev 1009
Copyright © KBC Networks Ltd.
Page 10 of 20
www.kbcnetworks.com
2.6
Grounding / Earthing
The ESUL6-FL2 has an earth point located on the top panel of the switch. To achieve
the best earth connection, a circular cold-press terminal should be crimped to one
end of the earth wire and attached to the unit with the screw, making sure that the
star washer stays in contact with the body of the switch. The cross-section of
grounding wire should not be less than 2.5mm
2
.
2.7
DIP Switch Setting
The DIP switch settings are used to set either the fiber uplink ports to redundant
mode (in a ring configuration) or straight-through (not in a ring configuration) and if
they are in redundant mode then whether they are a master or slave.
Note
: In a redundant ring network, only one switch can be set as the master and
others are set as slaves.
DIP Switch Position
Device
Operation
Position
Schematic
Logic
Position
1 2
ON
T
F
T
OFF
The uplink fiber ports
are in redundant mode
and the switch is set as
the slave.
F
OFF
1 2
ON
T
F
T
OFF
The uplink redundant
fiber ports are in
redundant mode and
the switch is set as a
master.
F
ON
1 2
ON
T
F
1 2
ON
T
F
T
ON
Uplink fiber ports are in
straight-through mode.
F
ON/OFF