CONTENTS
PAGE
1.
INTRODUCTION
1.1 General information
■ These units are used for both heating and cooling applications.
They can be combined with fan coil units, floor heating
applications (connect the mixed station), low temperature high
efficiency radiators (field supply).
■ The host unit controller is standard supplied with the unit to control
the system.
■ A wired remote controller can also be used to control the system
(Optional).
■ Operation range
COOLING MODE
HEATING MODE
t(°C)
t(°C)
46
27
35
0
-5
-15
4 7
15
20 t(°C)
35 40
54 t(°C)
DELIVERY WATER TEMPERATURE
DELIVERY WATER TEMPERATURE
(*) The unit can not operate in cold weather conditions below -15
℃
. If
it is necessary to operate, an external auxiliary heat source must
be added as a backup heater. the backup heater also serves as a
backup in case of malfunctioning of the unit and for freeze
protection of the outside water piping during winter time.
These models have an antifreeze function that allows the use of
heat pumps to keep the water system free from freezing under all
conditions. If there is an accident or intentional power outage, it is
recommended to use ethylene glycol.
1.2 Scope of this manual
This installation & owner's manual does not include the selection
procedure and water system design procedure. Only some
precautions and tips and tricks about the design of the water circuit
are given in a separate chapter of this manual. Once the selection is
done and the water system is designed, this manual describes the
procedures for handling, installing and connecting the unit. This
manual has been prepared to ensure adequate maintenance of the
unit, and it will provide help if problems occur.
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE
FOR FUTURE REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCKS, SHORT-CIRCUITS, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE TO
ONLY USE ACCESSORIES MADE BY THE SUPPLIER
WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH
THE EQUIPMENT AND HAVE INSTALLATION DONE BY A
PROFESSIONAL
ALL ACTIVITIES DESCRIBED IN THIS MANUAL SHALL BE
CARRIED OUT BY A LICENSED TECHNICIAN.
BE
SURE
TO
WEAR
ADEQUATE
PERSONAL
PROTECTION SUCH AS GLOVES AND SAFETY GLASSES
WHEN PERFORMING INSTALLATION, MAINTENANCE
OR SERVICE TO THE UNIT.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
CONTACT YOUR DEALER FOR GUIDANCE
2.
ACCESSORIES
2.1 Accessories supplied with the unit
1. INTRODUCTION. ....................................................................... 1
2. ACCESSORIES. ........................................................................ 1
3. SAFETY CONSIDERATIONS. ................................................. 2
4. OVERVIEW OF THE UNIT. ....................................................... 3
5. UNIT INSTALLATION. .............................................................11
6 START-UP AND CONFIGURATION. ..................................... 25
7.THE HOST UNIT CONTROLLER ELUCIDATION. ................. 27
8.TROUBLE SHOOTING. ............................................................ 31
9.IMPORTANT INFORMATION FOR THE USED
REFRIGERANT.........................................................................32
10. MAIN PARAMETERS. ........................................................... 33
Unit
Qty.
Shape
Installation &
Owner’s Manual
1
Rubber ring for wires
(only 10~16kW)
2
Outflow connecting
tube (for the chassis)
1
Straight screwdriver
1
Y-shaped filter
1