17
8.2.3 Double zone control
Code Assembly unit
Code Assembly unit
1
Main unit
2
4
User interface
4.1
Balance tank (Field supply)
19
4.2
Automatic air purge valve
21
Collector/distributor (Field supply)
5
Drainage valve
Thermostat transfer board (optional)
23
P_o: zone 1 circulation pump (Field supply) RT 1…7 Low voltage room thermostat (Field
supply)
23.1
Mixing station (Field supply)
RT8
High voltage room thermostat (Field supply)
23.2
SV3: Mixing valve (Field supply)
Tw2
Zone 2 water flow temperature sensor
(Optional)
12
P_c: zone 2 circulation pump (Field supply)
FHL
1…n
Floor heating loop (Field supply)
RAD.
1...n
Radiator (Field supply)
Filter (Accessory)
10
Expansion vessel (Field supply)
14
Shut-off valve (Field supply)
16
Drainage valve (Field supply)
15
Filling valve (Field supply)
4
4.2
4.1
10
FHL1
FHL2
FHLn
19
Outdoor
Indoor
Tw2
23
23.123.2
5
RAD.1
RAD.2
RAD.n
ZONE1
ZONE2
RT2
RT3
21
RT4
RT5
RT7
RT6
RT8
RT1
2
Modbus
15
16
14
12
14
16
1
1
)
Make sure to connect the SV2/SV3 terminals in the wired controller correctly, please refer to 9.7.6/2) for 3-way
valve SV1, SV2, SV3.
2
)
Make sure thermostat wires to the correct terminals and to configure the ROOM THERMOSTAT in the wired
controller correctly. Wiring of the room thermostat should follow method A/B/C as described in 9.6.7 “Connection
for other components /5) For room thermostat”.