background image

kawneer.com

Laws and building and safety codes gover

ning the design and use of glazed 

entrance, window

, and curtain wall pr

oducts vary widely

. Kawneer does not contr

ol 

the selection of pr

oduct configurations, operating har

dwar

e, or glazing materials, 

and assumes no r

esponsibility ther

efor

.

Kawneer r

eserves the right to change configuration without prior notice when deemed

necessary for pr

oduct impr

ovement.

© Kawneer Company

, Inc., 2013

2

038310

EC 95424-057

15/16"

3/8"

#8-32 x 1-15/16" FHMS

KAWNEER 1686 CONCEALED EXIT DEVICE

INSTALLATION INSTRUCTIONS

FEBRUARY, 2015

CYLINDER PAD ASSEMBLY:

1)  Insert a 15/16" cylinder into the mounting pad and secure with the retaining ring.

 

Note: If using a cylinder longer than 15/16", cylinder

 

 

rings will be required to maintain the 3/8" projection.

Cylinder

Mounting Pad

15/16" Cylinder

with 0.800" cam

Retainer

Ring

Insert cylinder assembly
into cutout.

CYLINDER INSTALLATION:

1)  On exterior side of door, install the cylinder assembly into cutout on the door stile.
2)  On interior side of door, install (2) #8-32 x 1-15/16" FHMS through door stile to secure cylinder assembly in position.
3)  Cylinder assembly should be tightly secured to ensure that mounting pad is placed square upon door stile and cannot be moved.
4)  Once the center case assembly and mounting pad is secured on the active door stile, insert cylinder key and turn counterclockwise to  

 

 

deactivated exterior cylinder dogging mechanism.

Summary of Contents for 1686

Page 1: ...n two bracket retaining fasteners 2 Discard dogging pawl 3 Reinstall the bracket and retaining fasteners within the exit device housing Bracket CENTER CASE INSTALLATION 1 Using a hook tool align cente...

Page 2: ...into the mounting pad and secure with the retaining ring Note If using a cylinder longer than 15 16 cylinder rings will be required to maintain the 3 8 projection Cylinder Mounting Pad 15 16 Cylinder...

Page 3: ...linder on inactive door leafs place the lock arm switch in a lock position to disable the lever handle function 5 Prior to installation of trim mounting base the cylinder dogging pawl must be removed...

Page 4: ...4 057 10 24 PFHMS KAWNEER 1686 CONCEALED EXIT DEVICE INSTALLATION INSTRUCTIONS FEBRUARY 2015 TO DOG EXIT DEVICE Insert the hex key and turn clockwise until it stops Fully depress touch bar and release...

Page 5: ...GGING 1 Install pivot stile filler plate into exit device 2 Install cylinder as pictured making sure cylinder is tight against filler plate MAKE SURE CYLINDER IS ORIENTED AS PICTURED 3 Tighten set scr...

Page 6: ...som hump back strike plate prep can adjust the top bolt approximately 7 16 to allow the top and bottom bolts to remain retracted within the bolt guide trigger mechanism when push pad is not completely...

Page 7: ...erefor 7 038310 EC 95424 057 KAWNEER 1686 CONCEALED EXIT DEVICE INSTALLATION INSTRUCTIONS FEBRUARY 2015 1 32 1 32 0 874 0 719 0 562 0 437 0 281 0 874 0 719 0 562 0 437 R 0 1 5 6 T Y P 0 281 C L OF THR...

Page 8: ...VOT END CAP BLACK MATT FINISH 4 1 EA 8 32 PANIC ATTTACHMENT FASTENER 5 1 EA 12 24 PANIC ATTACHMENT FASTENER 7 4 EA HOUSING COVER ATTACHMENT FASTENERS BLACK 8 1 EA HINGE PIVOT STILE ATTACHMENT FASTENER...

Page 9: ...the design and use of glazed entrance window and curtain wall products vary widely Kawneer does not control the selection of product configurations operating hardware or glazing materials and assumes...

Page 10: ...perating hardware or glazing materials and assumes no responsibility therefor Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement Kawn...