background image

SYSTEM 

LIMITATIONS

Must be read prior to use

Kattsafe recommends that persons using fall arrest 
systems do not work alone in case of an emergency 
and help is required.

Should any part of the system/equipment have 
been subjected to abnormal loading, use must 
be discontinued until replaced/recertified by a 
competent height safety inspector.

1.  Vertical fall arrest systems and vertical ladders require 

persons who are competent and trained in the safe use 
of the system. It is the responsibility person in control of 
the business or undertaking to ensure that they comply 
with state work, health and safety regulations and that 
they have assessed the hierarchy of risk control measures 
and alternative systems cannot be used.

2.  The vertical fall arrester is designed for single person use 

only rated to maximum user weight - 140kg. (Person and 
carry tools).

3.  Fall arrest equipment is susceptible to deterioration when 

exposed to chemicals or hazardous environments and 
must be approved by the manufacturer for use in these 
applications.

4.  This system, under normal use and environment, has 

a life expectancy of up to 10 years. A manufacturer’s 
assessment and certification to confirm suitability for an 
additional 5 years’ use is recommended. This will depend 
on location, usage and scheduled maintenance as per 
manufacturer and legislative requirements.

5.  The structural requirements for the ladder to which the 

vertical fall arrester is connected to must be able to 
withstand the loads applied in the event of a fall which is 
12kN (see fixing requirements recommendation).

6.  The vertical fall arrester is designed for vertical climbing 

systems only to ensure correct operation of the fall arrest 
device. The fall arrest line system must not exceed 10° off 
vertical.

7.  Only the approved SL228 vertical line fall arrester with 

energy absorber shall be used with this system. An in-line 
energy absorber must be installed for any system that 
does not include an energy absorber built in with the fall 
device.

8.  All ladders fitted with a fall arrest system require a 

security cover or lockable access door or device to 
prevent unauthorised use of the ladder.

9.  The vertical line fall arrester is not designed for use on 

portable ladders or structures.

10.  Do not tamper with or make alterations to system 

components without manufacturer’s consent.

11.  This system is not to be used for tethering or lifting 

machinery or equipment.

12.  The vertical line fall arrester must be recertified by a 

competent height safety inspector as recommended:

 

– Non-corrosive/mild environment – 12 monthly

 

– Corrosive/ harsh environments - 6 monthly (more 

frequently inspection may be required)

Copyright, trademarks and product codes are property of Kattsafe. Patents and 
design registrations may apply to these products.

5

Kattsafe / Vertical fall arrester / Operation manual

Summary of Contents for SL228

Page 1: ...Manual must be read and understood prior to use VERTICALFALL ARRESTER OPERATIONMANUAL SL228...

Page 2: ...ders Arrester for personnel accessing heights using a harness and fall arrest ladder protection system Find all related products and resources on our website kattsafe com au Operation manual Vertical...

Page 3: ...afe recommendations fulfill current workplace requirements for the safety of building maintenance subcontractors employees and the general public For more information please contact Kattsafe kattsafe...

Page 4: ...there is any deterioration or deformation of any components or structure to which the system is attached 9 If the safety system is damaged or has arrested a fall discontinue use until it has been ful...

Page 5: ...urer and legislative requirements 5 The structural requirements for the ladder to which the vertical fall arrester is connected to must be able to withstand the loads applied in the event of a fall wh...

Page 6: ...ttle onto its side and insert cable into horizontal port Step 4 Return shuttle to vertical position which will locate shuttle onto cable Shuttle must be used with a tear web energy absorbing lanyard c...

Page 7: ...arness Ensure carabiner screw gate is locked Step 7 Check the shuttle is functioning correctly and all carabiner screw gates are secure Step 8 Climb ladder using care at all times Copyright trademarks...

Page 8: ...the cam and lowering the shuttle Any damage to harness gear or static line system during use MUST be reported to the workplace manager and removed or tagged out of service until recertified by a compe...

Page 9: ...completed confirming maintenance and recertification of the system Failure to follow all warnings operation and maintenance instructions may result in serious injury or death 6 Harness gear and equip...

Page 10: ...Y N Corrective action Completion date Must be no deterioration of ladder fixing bracket integrity to support structure and ladder fixing Must be no visible deterioration or damage to ladder Must be no...

Page 11: ...designed to conform with requirements of Australian and New Zealand Standards AS NZS 1891 4 2009 and codes of practice and guidelines Testing Testing and performance based on requirements of Australia...

Page 12: ...vellers fall arresters etc will void warranty Systems components used for purposes other than their intended use will void warranty General wear and tear is expected and will depend on the frequency o...

Page 13: ...00 301 755 sales kattsafe com au kattsafe com au Find all related products and resources on our website kattsafe com au Operations manual Vertical fall arrester Installation manual Vertical fall arres...

Reviews: