Malfunctions and Defects 

If you notice any kind of defect, remove the batteries from the smoke detector FRM 

100 and contact your retailer or KATHREIN Digital Systems GmbH directly. Any further 

usage of the system may lead to fire or electric shock! 

Intended Use 

The KATHREIN Digital Systems GmbH smoke detector is intended for the building 

security. Install the smoke detector indoors only. Any other use than that described 

in this manual is not permitted and will void any warranty or guarantee as well as 

liability claims. The same applies if the device is modified or retrofitted. 

Disposal 

 

Do not dispose of the device with domestic waste! 

This product complies with the EU Directive on waste electrical and 

electronic equipment (WEEE) and therefore must not be disposed of 

with domestic waste. 

Dispose of the device via your local 

collection 

point for waste electronic equipment! 

 
This product contains software programs subject to the GPL free software license. 

 
This product contains software that was developed by third parties and/or software 

subject to the GNU General Public License (GPL) and/or the GNU Lesser General 

Public License (LGPL). We will send you the source code of these programs on request. 

The GPL and/or LGPL code used and offered in this product is EXCLUSIVE OF ANY 

GUARANTEE WHATSOEVER and is subject to the copyright of one or several authors. 

For further details, please refer to the GPL and/or LGPL code of this product and to 

the terms of use of GPL and LGPL. 
 
You can read the complete license text a

http://www.gnu.org/licenses/gpl-2.0.html

. 

For an unofficial German translation, please go to  
http://www.gnu.de/documents/gpl.de.html. 

 

 

Summary of Contents for 2220000008

Page 1: ...1 1 User Manual FRM 100 2220000008 Smoke Detector ...

Page 2: ...ns in this manual were compiled with the greatest care However KATHREIN Digital Systems GmbH cannot entirely exclude mistakes in this manual Therefore we do not assume any legal responsibility or liability resulting from wrong information in this manual Descriptions technical illustrations and technical data are subject to change without notice according to technical progress In addition KATHREIN ...

Page 3: ...posure when operating the device in a commercial environment This product generates uses and may emit radio energy It may in addition interfere with other radio communication systems if not installed or used according to this manual Using the device in residential areas may cause disturbances to be possibly remedied at the user s expense Hereby KATHREIN Digital Systems GmbH declares that the Smoke...

Page 4: ...r close to strong electric power lines or magnetic fields as this may impair the transmission quality significantly Do not install the smoke detector directly on iron or aluminium surfaces as this may impair the wireless transmission significantly Use a non conducting material to insulate the device from the installation surface Do not install the smoke detector in moist very cold or very hot envi...

Page 5: ...uipment WEEE and therefore must not be disposed of with domestic waste Dispose of the device via your local collection point for waste electronic equipment This product contains software programs subject to the GPL free software license This product contains software that was developed by third parties and or software subject to the GNU General Public License GPL and or the GNU Lesser General Publ...

Page 6: ... In case of fire the siren s of the alarm panel will likewise sound an alarm Sensor data Dimensions without mount Ø 10 6 x 4 4 cm 4 17 x 1 73 in Weight 220 g 0 48 lbs Place of installation Only indoors walls corners Operating temperatures 10 C to 45 C 14 F to 113 F Humidity Maximum 95 non condensing Radio frequency 868 6375 MHz Detection method Optical Conforms to the following standards DIN EN 54...

Page 7: ... also recommended to equip all common rooms living rooms studies etc as well as cellars boiler rooms and corridors with smoke detectors If your building has more than one floor we recommend installing at least one smoke detector per floor The maximum coverage area is 60 m2 For larger rooms the number of smoke detectors must be increased The smoke detector should be installed centrally at the highe...

Page 8: ...rief signals and the LED begins to flash During the warm up phase of six minutes you can connect the smoke detector with your alarm panel 2 Open the web interface of the alarm panel go to the menu Sensors Add and press Start 3 Press the Learn button of the smoke detector Two brief signals are emitted 4 The alarm panel will confirm the successful addition of the smoke detector with a brief signal t...

Page 9: ...triggered by a fire The building should be evacuated immediately False alarm troubleshooting The smoke detector triggers but there are no apparent reasons The alarm of the smoke detector needs to be turned off directly at the smoke detector o Press the Learn button of the smoke detector to deactivate the alarm and activate the sleep mode After ten minutes the smoke detector will beep 2 times and i...

Page 10: ...r carefully or blow out the dust e g with a compressor The KATHREIN Digital Systems GmbH is not liable for contaminations This is considered normal wear Maintenance The function of the smoke detector should be checked regularly Learn button and if necessary cleaned To ensure proper function of the smoke detector it is recommended to check the smoke detector immediately after installation Press the...

Page 11: ..._______ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ ___________________________________...

Page 12: ..._______________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ ___________________________...

Reviews: