WARNING: 

 

TO MINIMISE THE RISK OF ELECTRIC SHOCK, YOU MUST NOT EXPOSE THIS PRODUCT 

TO WET AND MOIST CONDITIONS AT ANY TIME. 

 

 

All KATHREIN Digital Systems GmbH products are lead-free and meet 

the requirements stated under the European Directive on the 

Restriction of Hazardous Substances (RoHS). This guarantees that 

the entire production process and the product itself are free of lead 

and of all listed hazardous substances. 

 

This product was tested and complies with the regularities for a class 

of  digital devices stated under FCC part 15. These limits were 

specified to provide reasonable protection against harmful exposure 

when operating  the device in a commercial environment. This 

product generates, uses and  may emit radio energy. It may in 

addition interfere with other radio  communication systems if not 

installed or used according to this manual.  Using the device in 

residential areas may cause disturbances to be possibly remedied at 

the user’s expense. 

 

Hereby KATHREIN Digital Systems GmbH declares that the Smoke 

detector FRM 100 (order number 2220000008, EAN 4021121548857) is 

in conformity with the relevant provisions of Directive 1999/5/EG. 

 

 

Conformity: 

 

The declaration of conformity is available at http://www.kathrein-ds.com in 

the download section of the respective product. Alternatively, you can 

request the declaration of conformity directly from us: 

KATHREIN Digital Systems GmbH 

Anton-Kathrein-Str. 1–3 

83022 Rosenheim, Germany 

 

 

Summary of Contents for 2220000008

Page 1: ...1 1 User Manual FRM 100 2220000008 Smoke Detector ...

Page 2: ...ns in this manual were compiled with the greatest care However KATHREIN Digital Systems GmbH cannot entirely exclude mistakes in this manual Therefore we do not assume any legal responsibility or liability resulting from wrong information in this manual Descriptions technical illustrations and technical data are subject to change without notice according to technical progress In addition KATHREIN ...

Page 3: ...posure when operating the device in a commercial environment This product generates uses and may emit radio energy It may in addition interfere with other radio communication systems if not installed or used according to this manual Using the device in residential areas may cause disturbances to be possibly remedied at the user s expense Hereby KATHREIN Digital Systems GmbH declares that the Smoke...

Page 4: ...r close to strong electric power lines or magnetic fields as this may impair the transmission quality significantly Do not install the smoke detector directly on iron or aluminium surfaces as this may impair the wireless transmission significantly Use a non conducting material to insulate the device from the installation surface Do not install the smoke detector in moist very cold or very hot envi...

Page 5: ...uipment WEEE and therefore must not be disposed of with domestic waste Dispose of the device via your local collection point for waste electronic equipment This product contains software programs subject to the GPL free software license This product contains software that was developed by third parties and or software subject to the GNU General Public License GPL and or the GNU Lesser General Publ...

Page 6: ... In case of fire the siren s of the alarm panel will likewise sound an alarm Sensor data Dimensions without mount Ø 10 6 x 4 4 cm 4 17 x 1 73 in Weight 220 g 0 48 lbs Place of installation Only indoors walls corners Operating temperatures 10 C to 45 C 14 F to 113 F Humidity Maximum 95 non condensing Radio frequency 868 6375 MHz Detection method Optical Conforms to the following standards DIN EN 54...

Page 7: ... also recommended to equip all common rooms living rooms studies etc as well as cellars boiler rooms and corridors with smoke detectors If your building has more than one floor we recommend installing at least one smoke detector per floor The maximum coverage area is 60 m2 For larger rooms the number of smoke detectors must be increased The smoke detector should be installed centrally at the highe...

Page 8: ...rief signals and the LED begins to flash During the warm up phase of six minutes you can connect the smoke detector with your alarm panel 2 Open the web interface of the alarm panel go to the menu Sensors Add and press Start 3 Press the Learn button of the smoke detector Two brief signals are emitted 4 The alarm panel will confirm the successful addition of the smoke detector with a brief signal t...

Page 9: ...triggered by a fire The building should be evacuated immediately False alarm troubleshooting The smoke detector triggers but there are no apparent reasons The alarm of the smoke detector needs to be turned off directly at the smoke detector o Press the Learn button of the smoke detector to deactivate the alarm and activate the sleep mode After ten minutes the smoke detector will beep 2 times and i...

Page 10: ...r carefully or blow out the dust e g with a compressor The KATHREIN Digital Systems GmbH is not liable for contaminations This is considered normal wear Maintenance The function of the smoke detector should be checked regularly Learn button and if necessary cleaned To ensure proper function of the smoke detector it is recommended to check the smoke detector immediately after installation Press the...

Page 11: ..._______ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ ___________________________________...

Page 12: ..._______________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ ___________________________...

Reviews: