background image

 

15 

 

 

Check the filter elements using the measuring gauge. To do so, refer to Chapter 
7.3 in this

 

manual: 

“Examining the filter elements.” 

 
 
 
 
 
 
 
 
 

 

 

Start the Pump 

 

Open cleaning valve C 

 

Clean the filter elements and inside of the housing with the 
cleaning hose. 

 

Close cleaning valve C 

 

Stop the Pump 

 

Open the drain valve D and empty the filter housing 

 

Replace the cover 

 

The MOT-7 is ready for refilling or for storage 

 
 
 
 
 
 
 
 
 
 

 

Before storage, the filter elements must air dry for at least two days. 

 

 

 

 

 

 

A

D

C

Summary of Contents for MOT-7

Page 1: ...1 MobileMicrofiltrationSystem MOT 7 Water treatment with Katadyn ceramic filters...

Page 2: ...entration 7 3 6 Installation requirements of components 8 3 7 Flow rates of the MOT 7 8 4 1 Setup Procedure 9 5 1 Setup procedure 10 6 1 Brief description of the handle position of operational compone...

Page 3: ...eral Safety Guidelines The mobile Microfiltration System MOT 7 from Katadyn has been factory tested The dangers of improper use or failing to follow the operating procedures outlined in this manual ma...

Page 4: ...in this supplement Only when these are followed without exception can operators and others avoid the loss of life and serious injuries or avoid interference with the system s operation or other materi...

Page 5: ...safety operations and maintenance instructions and improper repairs Improper use of the MOT 7 use not in compliance with instructions Use of repair parts not permitted by the MOT 7 manufacturer Opera...

Page 6: ...filters are made from various natural raw materials of the highest quality standard As such we can attain a nominal pore size of 0 2 m with insignificant variations 3 2 Primary features of mobile micr...

Page 7: ...ments become dirtier the flow rate also decreases accordingly Intervals between cleanings can be influenced positively with the appropriate placement of the suction hose Placing the hose directly unde...

Page 8: ...resh water outlet Drain water outlet Cleaning hose connection hose is enclosed Sample valve outlet 3 7 Flow rates of the MOT 7 The above chart shows the typical performance of the unit when operated i...

Page 9: ...6 kW Rated speed 3600 U min Tank Capacity 3 1 L Consumption l h 1 6 Measurements LxWxH 435 x 375 x 400 mm Weight 23 5 kg Please refer to the accompanying Honda Manual regarding the correct handling o...

Page 10: ...ice 5 1 Setup Procedure Take care that the filter unit is placed in a stable position and that the location surface is dry Remove the No 5 filter elements from the package and screw them hand tight in...

Page 11: ...11 Hook up the cleaning hose to the corresponding threads The MOT 7 is now ready for use...

Page 12: ...t Valve B Sample Valve E Open Close 6 2 Filling Venting Check that all valves are closed Start the motor and vent the pump Turn the main valve A counter clockwise to open Open vent valve B just slight...

Page 13: ...g 6 5 Water Sampling Sampling must be performed by an experienced person according to DIN EN 25667 2 procedures The mobile Microfiltration System MOT 7 must be set in the operational mode see chapter...

Page 14: ...lve D as soon as the filter elements are standing in water by 1 6 only Put the cleaning brush over the filter element and move it up and down 6 8 times and at the same time flush with water from the p...

Page 15: ...the Pump Open cleaning valve C Clean the filter elements and inside of the housing with the cleaning hose Close cleaning valve C Stop the Pump Open the drain valve D and empty the filter housing Repla...

Page 16: ...se the sampling valve Pump unit delivers too little water Motor is not running at the max speed Suction filter not completely covered in water or dirty Optimize the suction filter Clean the filter Suc...

Page 17: ...t Number Description Picture 7010719 V Band Clamp M MOT7 MF 7 20621 SET Cleaning Hose M MOT7 complete 20616 Cleaning Brush for Katadyn Filter elements 20335 Measurement gauge for Katadyn Filter elemen...

Page 18: ...tadyn Filter element No 5 128031 O Ring Seal 268 x 16mm 7010633 Suction Hose M MOT7 incl coupling to Pump 20615 1 Pair of Brush Segments Nylon 20619 1 Pair of Brush Segments Bronze Option for difficul...