background image

15

14

mAINtENANcE

lImItED WARRANtY

KASSEL SANITÄR S.L. warrants that its electronic products will be free of defects in 
material and workmanship during normal use for two years from the date the product is 
purchased. 

If a defect is found in normal use, KASSEL SANITÄR S.L. will, at its discretion, repair, 
provide a replacement part or product, or make appropriate adjustments. Damage caused 
by accident, misuse, or abuse is not covered by this warranty. Improper care and cleaning 
will void the warranty. Proof of purchase (original sales receipt) must be provided to 
KASSEL SANITÄR S.L. with all warranty claims. 

KASSEL SANITÄR S.L. is not responsible for labor charges, installation, or other incidental 
or consequential costs other than those noted above. In no event shall the liability of 
KASSEL SANITÄR S.L. exceed the purchase price of the product. 

If you believe that you have a warranty claim, contact your Kassel Distributor, Dealer 
or Plumbing Contractor. Please be sure to provide all pertinent information regarding 
your claim, including a complete description of the problem, the product, model number, 
the date the product was purchased, from whom the product was purchased and the 
installation date. Also include your original invoice. 

KASSEL SANITÄR S.L. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL, 
INCIDENTAL OR CONSEQuENTIAL DAMAgES. This warranty excludes product damage 
due to installation error, incorrect maintenance, wear and tear, battery,  product abuse, or 
product misuse, whether performed by a contractor, service company, or the consumer. 
This warranty does not cover product damage caused by the following: 

- Incorrect installation. 

- inversions of supply pipes.

- Pressures or temperatures exceeding recommended limits.

- Improper manipulation, tampering, bad or lapsed maintenance. 

- Foreign bodies, dirt or scale introduced by the water supply or soap tank.

- use of the soap outside of viscosity specifications.

- Alteration of the original soap/foam dispenser components (including pipes).

If system chemical disinfection is practiced, chlorine can be used (calculated 

chlorine concentration of 50mg/l maximum in water per one hour dwell time) 

at service interval frequency.

fIltER clEANING INStRuctIONS

These models are provided with a stainless steel filter preventing foreign particles 

to enter the lines. It is recommended to clean the filter every six (6) month. If the 

water flow has decreased, this may be because the filter is clogged. The filter can 

be cleaned as follows:
a. Shut-off the water shut off valve.
b. Disconnect the water supply pipe from the adaptor and disassemble the filter.
c. Wash the filter under running water.
d. Reassemble the parts.
e. Restore the incoming water supply and make sure that there is no water    

    leakage.

SOlENOID VAlVE  SERVIcING

The

 

solenoid valve diaphragm requires periodical cleaning every six (6) month. 

Remove the diaphragm from the solenoid valve and examine it for dirt. in case it 

is dirty or clogged, wash it under running water and reassemble it. 
Do not attempt to dismantle the solenoid valve if you are unfamiliar with 

electronic solenoid valves.

cARE AND clEANING Of chROmE AND SPEcIAl fINIShES
DO NOt

 use steel wool or cleansing agents containing alcohol, acid, abrasives, or 

the like. use of any prohibited cleaning or maintenance products or substances 

could damage the surface of the faucet. For surface cleaning of faucet us 

ONlY

 

soap and water, then wipe dry with clean cloth or towel. When cleaning bathroom 

tile, the faucets should be protected from any splattering of harsh cleansers.

Summary of Contents for RONDA N DP Series

Page 1: ...RONDA N DP RONDA N D O DP SERIES Wall mounted electronic faucet OPERATION AND INSTALLATION guide...

Page 2: ...l information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particula...

Page 3: ...proof solenoid housing with inlet nipple and filter BATTERY VERSION mains VERSION 1 x Dual power input box with inlet nipple and filter 1 xTransformer OPERATION This faucet features an IP67 dual power...

Page 4: ...steel 3 If a sink strainer is straight below the faucet sensor use a strainer with a non reflective finish do not use a chrome plated one Min 300 mm Bottom of the washbasin Preparation for installati...

Page 5: ...the works on electricity plumbing and tiles have been finished assemble the wall rosette through the product base wall rosette 10 Pull the sensor wire s out of the product base and lead it them along...

Page 6: ...the system to set the ideal sensor range SECONDS ABOUT 15 As an indication that the self adjusting has taken place a LED in the sensor eye will flash continuously The solenoid valve will open and clos...

Page 7: ...nly If required the delay in time can also be modified in faucets as follows Press the IN button Wait until a quick flashing of the LED in the sensor eye is perceived Then press to increase the delay...

Page 8: ...ery weakens the LED indicator light will blink at a constant rate The battery must be replaced within two weeks Important These models were supplied with a self adjusting sensor The ideal sensor range...

Page 9: ...ipes Pressures or temperatures exceeding recommended limits Improper manipulation tampering bad or lapsed maintenance Foreign bodies dirt or scale introduced by the water supply or soap tank Use of th...

Page 10: ...nsor s range Clean the orifice or replace diaphragm 2 The central orifice in the diaphragm is plugged or the diaphragm is torn Reduce the supply water pressure 3 The water supply pressure is higher th...

Page 11: ...Kassel Sanit r S L Avda de Castilla 1 Pol gono Industrial 28830 San Fernando de Henares Madrid Spain Daimlerstra e 2 D 93133 Burglengenfeld Germany Tel 34 916 778 993 Fax 34 916 777 774 info kassel e...

Reviews: