background image

2

THANKS

We at Kasco Marine, Inc. would like to both thank and 

congratulate you on your purchase of the xStream fountain.  

We appreciate you choosing Kasco and for your purchase.  

Your decision to purchase Kasco’s xStream Fountain will 

not disappoint you.  The fountain will be a great addition to 

your body of water.  It will help improve the water quality 

by adding much needed oxygen and circulation.  It will also 

enhance the aesthetics of the pond or lake with a beautiful 

fountain pattern.  The lighting package (if purchased) will 

illuminate your fountain for beauty at night.  We thank you 

for choosing Kasco for your fountain needs and want you 

to be completely satisfied with your purchase.

Important Safety

Please read and follow these extremely important safety 

and handling instructions for your Kasco equipment.  

Following these instructions will help ensure your safety 

and the quality performance of your equipment.

•  Under NO circumstances should anyone enter the 

water with the electrical equipment plugged in and/or 

in operation.  All Kasco equipment is ETL approved 

to UL and CSA standards for safety in water and all 

fountain models include control panels with GFI 

protection.  However, it is NEVER recommended to 

enter the water with the equipment in operation.

•  Caution should be used when dealing with any 

electrical equipment with moving parts.

•  NEVER run the unit out of water.  It will damage the 

seals and create a dangerous situation for the operator.

•  Extreme caution should be used around water, 

especially cold water, such as in Spring, Fall, and 

Winter, which poses a hazard in and of itself.

•  NEVER lift or drag the fountain by the power or light 

cord.  If you need to pull the unit to the side of the 

pond, use the anchoring ropes.

•  Do not use waders in deep ponds/lakes or ponds/lakes 

with drop-offs, drastic slopes, or soft bottom material.

•  Do not use boats that tip easily for fountain installation, 

such as a canoe, and follow all boating safety rules 

and regulations, including wearing a PFD. (Personal 

Flotation Device)

•  The fountain is supplied with an internal grounding 

conductor and a grounding-type attachment plug.  To 

reduce the risk of electrical shock, be certain that the 

fountain is plugged into the C-25 Control Box (120V) 

supplied by Kasco and that the C-25 is plugged into 

a properly grounded, grounding type receptacle.  The 

GFCI breakers should be tested upon each installation 

and every month thereafter to ensure proper operation.

General Instructions

INSPECT THE SHIPMENT

Immediately inspect your Kasco Fountain shipment for any 

visible damages.  Also cross reference the parts supplied 

with the Parts Included sheet to check for shortages.  

Shortages should be reported immediately to your Kasco 

Marine distributor or representative and damages reported 

to your carrier and Kasco Marine.

CAUTION

WARNING:  Under NO circumstances should anyone enter 

the water with the unit in operation.  Always operate the 

unit in the water and keep people and objects clear of the 

propeller.  Do not lift or pull the unit by the electrical cord.  

Always use extreme caution around electrical equipment 

and water situations.

ASSEMBLY & INSTALLATION

Please see the proper Assembly and Installation Instructions 

enclosed in this manual.  Each is specific for your model 

and size of Fountain.  Note:  Use a nylon tie on power 

cords to the float for strain relief.  If you have a light kit, 

make sure that the unit cord is tied to one side of the float 

and the light cord to the other for balance.  Note: It is 

extremely important to test the GFI breaker in the control 

panel upon each installation/reinstallation of the unit to 

ensure proper functioning.

WARRANTY

Kasco Fountains are the result of over 40 years of design 

and engineering.  Kasco products are built to withstand the 

toughest conditions.  Kasco Marine backs each 2400SF 

model Fountain with a 1 Year Warranty.  This warranty 

covers any and all manufacturers defects within 1 year 

from the date of purchase (See Warranty & Return Policy).  

Please register your Fountain online at: www.kascomarine.

com (Under the Technical tab)

USE AND OPERATION

Kasco Fountains are designed and engineered for 

continuous duty, such as on fish farms or other aquaculture 

applications, or on-demand use, as needed in a recreational 

water feature.

During flotation operation, the water is pulled from 360

O

 

around the unit and from below the unit.  The water is 

pulled upward and thrust through the flotation collar into 

the air. 

Your Kasco Marine Fountain is ready for immediate 

use (after installation).  The motor and ball bearings 

are submerged in oil and no further lubrication is 

needed.  Make sure to keep the motor housing clean 

Summary of Contents for xStream 2400SF

Page 1: ...2 Control Panel Installation pg12 C 25 Timer Control Instructions pg13 Maintenance Recommendations pg14 Warranty Policy pg15 Troubleshooting Tips pg16 Replacement Parts pg18 Customer Repair Form pg19 Registration Information pg20 Rev 07 29 13 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 FAX 715 262 4487 www kascomarine com C Intertek 3020379 ANSI UL 778 5th Ed 2010 CAN CSA C22 2...

Page 2: ...ntrol Box 120V supplied by Kasco and that the C 25 is plugged into a properly grounded grounding type receptacle The GFCI breakers should be tested upon each installation and every month thereafter to ensure proper operation General Instructions INSPECT THE SHIPMENT Immediately inspect your Kasco Fountain shipment for any visible damages Also cross reference the parts supplied with the Parts Inclu...

Page 3: ...NIT and the C 25 plugged into a properly grounded receptacle See C 25 Instructions It is extremely important to test the GFI breaker in the control panel upon each installation and reinstallation and every month thereafter to ensure proper operation Kasco Fountains are lightweight energy efficient and easy to install and operate We strive to produce products that exceed customer expectations We ho...

Page 4: ...presentative immediately 2 Place float on motor housing The power cord notch on the float should line up with the cord See diagram below of bottom side of float The 3 bolt holes in the float should line up with bolt receptacles on unit power cord notch 3 Use one of the 1 4 20 x 3 1 4 Phillips Pan Head Screws one 1 4 split washer and a 1 4 Flat Washer to secure the float Make sure the split washer ...

Page 5: ...er two 1 4 flat washers and 1 4 nut Do not overtighten 1 4 flat washer 1 4 nut 1 4 lock washer 1 4 x 1 3 8 bolt Align this screen feature with this float feature 9 Flip the unit back over so that the stainless steel can is resting on a flat surface Use the Nylon Cable Tie included to secure the power cord to a molded hole in the float to prevent cord damage if there is no strain relief on the cord...

Page 6: ... chart and nozzle pictures to choose a pattern push plugs into the holes shown with black circles on the chart The number of possible patterns are not all shown on the following chart Nozzle Option Chart Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 1 6 18 2 4 5 18 3 6 5 18 5 Important Push in black plugs on the inside of the nozzle only Plugs on Inside ...

Page 7: ...7 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 4 5 18 5 5 6 5 18 5 6 5 18 5 7 7 17 8 5 5 17 9 7 21 ...

Page 8: ...8 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 10 5 5 21 11 7 21 12 4 5 21 13 7 21 14 5 5 21 15 7 5 20 ...

Page 9: ...9 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 16 6 20 17 7 5 23 18 5 5 23 19 8 21 20 5 5 21 21 8 13 ...

Page 10: ...10 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 22 6 5 13 23 8 25 24 4 25 25 8 25 26 6 5 25 27 8 5 13 ...

Page 11: ...11 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 28 6 5 13 29 8 5 22 30 5 22 31 8 5 24 32 4 24 33 8 5 24 ...

Page 12: ...electrical codes for this installation and Consult a qualified electrician or service person if needed Plug the aerator cord into the C 25 outlet labeled UNIT If lights are included plug the cord into the C 25 outlet labeled LIGHT Now you are ready to plug the C 25 NOTE Pattern sizes listed are approximate Variations in voltage caused by regional electrical differences or voltage drop due to long ...

Page 13: ...the connected equipment only Unplug timer before servic ing the unit or the equipment it controls THE MANUAL OVERRIDE KNOB IS NOT TO BE USED AS A POWER DISCONNECT For maximum protection against electri cal shock hazard perform test procedure on G F C I at least once a month Mount at least 5 ft from open water G F C I TEST PROCEDURE The G F C I should be checked every month to make sure that it is ...

Page 14: ...h the winter However when the water is thrust into the air it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32O F It is not necessary to store Kasco motors upside down All internal seals are fully lubricated while stored in an upright position CLEANING Fountains...

Page 15: ...nty claim Any expedited shipping method for the return of the unit is at the customer s expense Kasco Marine will return units repaired under warranty at our expense via ground freight within the continental United States Warranty Policy Warranty Period Model 2400SF 1 years Kasco Marine Inc warrants this Fountain to be free from defects in material or workmanship except for the ropes power cord an...

Page 16: ...s not getting the proper voltage This could also indicate a problem with the motor of the unit which needs to be looked at by an Authorized Repair Center Check that the unit is receiving the proper voltage and if so contact Kasco for further steps Other Repairs Most failed equipment can be repaired at substantially lower costs than replacement with new Please ship according to the instructions in ...

Page 17: ...he cause of the problem The problem could be one of many such as low water levels build up on the unit to prevent heat dissipation something inhibiting the free rotation of the shaft etc If something is caught in the unit or there is a build up of algae calcium or organic matter on the unit remove the debris and if caught early enough the unit should be fine Contact a Kasco representative before r...

Page 18: ...C ASSEMBLY 1 20 IN LBS 12 462237 1 2 20 waxed nut SS 1 13 361310 FLOW STRAIGHTENER 1 14 361320 NOZZLE 1 2 HP FOUNTAIN 1 15 361313 Oring 1 2 hp nozzle 1 16 840536 NUT 1 4 20 6 50 IN LBS 17 584692 1 4 20 X 1 3 8 BOLT 3 18 361543 8 flat washer 12 19 820405 SCREW 6x1 2 IN PH PHIL ULTRA SS 4 20 771033 Washer 8 split lock black oxide 6 21 475630 1 4 20 X 1 3 4 LONG BOLT 3 22 140312 RETAINING CLIP 3 23 3...

Page 19: ...clude the power cord and cage assembly fountain housing with each unit sent in for repair to be considered for warranty and for proper repair and shipping protection Do not ship the float and or control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address ____________________...

Page 20: ... 2400SF _______________________________ Serial Ex 2101S241025 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com 884361 ...