“My Fountain hums, but will not start.  When I spin 

the prop with a stick, it starts up.”

 

This indicated a problem with the Starting 

Capacitor.  Each Kasco Fountain is equipped with a 

Starting Capacitor to get the unit going when it is first 

plugged in.  If it is operating, but not spinning and can 

be started by spinning the prop with a stick, the Start-

ing capacitor needs to be replaced by an Authorized  

Repair Center.

“My Fountain turns itself off and back on without the 

timer and without tripping the GFI breaker.”

 

Each Kasco Fountain has a Thermal Overload 

built in that will turn the unit off when it overheats.  

Once the unit has cooled down, it will start back up.  If 

you are noticing these symptoms, the unit should be 

unplugged immediately because the Thermal Overload 

will continue to turn on and off until it burns out and 

damages the motor.  The unit should be unplugged and 

taken out of the water to find the cause of the problem.  

The problem could be one of many, such as, low water 

levels, build-up on the unit to prevent heat dissipation, 

something inhibiting the free rotation of the shaft, etc.  

If something is caught in the unit or there is a build-up 

of algae, calcium or organic matter on the unit, remove 

the debris and, if caught early enough, the unit should 

be fine.  Contact a Kasco representative before restart-

ing the unit.

“The GFI breaker trips randomly and sporadically.  

Sometimes it is a few hours of operation, other times it 

can be days or weeks.”

 

This is referred to as a Nuisance Trip.  This 

usually occurs where the unit is installed a great 

distance from the initial electric service on the prop-

erty where the ground stake is placed.  It is caused by 

either induced current in the ground wire or a base 

voltage difference due to soil pH levels.  To resolve 

the problem, contact an electrician and install a local 

grounding stake.  This may eliminate the induced cur-

rent and any base voltage differences.  This problem 

can also be caused by a bad breaker or receptacle or 
having unbalanced incoming voltage lines.

Summary of Contents for xStream 2400SF

Page 1: ...2 Control Panel Installation pg12 C 25 Timer Control Instructions pg13 Maintenance Recommendations pg14 Warranty Policy pg15 Troubleshooting Tips pg16 Replacement Parts pg18 Customer Repair Form pg19 Registration Information pg20 Rev 07 29 13 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 FAX 715 262 4487 www kascomarine com C Intertek 3020379 ANSI UL 778 5th Ed 2010 CAN CSA C22 2...

Page 2: ...ntrol Box 120V supplied by Kasco and that the C 25 is plugged into a properly grounded grounding type receptacle The GFCI breakers should be tested upon each installation and every month thereafter to ensure proper operation General Instructions INSPECT THE SHIPMENT Immediately inspect your Kasco Fountain shipment for any visible damages Also cross reference the parts supplied with the Parts Inclu...

Page 3: ...NIT and the C 25 plugged into a properly grounded receptacle See C 25 Instructions It is extremely important to test the GFI breaker in the control panel upon each installation and reinstallation and every month thereafter to ensure proper operation Kasco Fountains are lightweight energy efficient and easy to install and operate We strive to produce products that exceed customer expectations We ho...

Page 4: ...presentative immediately 2 Place float on motor housing The power cord notch on the float should line up with the cord See diagram below of bottom side of float The 3 bolt holes in the float should line up with bolt receptacles on unit power cord notch 3 Use one of the 1 4 20 x 3 1 4 Phillips Pan Head Screws one 1 4 split washer and a 1 4 Flat Washer to secure the float Make sure the split washer ...

Page 5: ...er two 1 4 flat washers and 1 4 nut Do not overtighten 1 4 flat washer 1 4 nut 1 4 lock washer 1 4 x 1 3 8 bolt Align this screen feature with this float feature 9 Flip the unit back over so that the stainless steel can is resting on a flat surface Use the Nylon Cable Tie included to secure the power cord to a molded hole in the float to prevent cord damage if there is no strain relief on the cord...

Page 6: ... chart and nozzle pictures to choose a pattern push plugs into the holes shown with black circles on the chart The number of possible patterns are not all shown on the following chart Nozzle Option Chart Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 1 6 18 2 4 5 18 3 6 5 18 5 Important Push in black plugs on the inside of the nozzle only Plugs on Inside ...

Page 7: ...7 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 4 5 18 5 5 6 5 18 5 6 5 18 5 7 7 17 8 5 5 17 9 7 21 ...

Page 8: ...8 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 10 5 5 21 11 7 21 12 4 5 21 13 7 21 14 5 5 21 15 7 5 20 ...

Page 9: ...9 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 16 6 20 17 7 5 23 18 5 5 23 19 8 21 20 5 5 21 21 8 13 ...

Page 10: ...10 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 22 6 5 13 23 8 25 24 4 25 25 8 25 26 6 5 25 27 8 5 13 ...

Page 11: ...11 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 28 6 5 13 29 8 5 22 30 5 22 31 8 5 24 32 4 24 33 8 5 24 ...

Page 12: ...electrical codes for this installation and Consult a qualified electrician or service person if needed Plug the aerator cord into the C 25 outlet labeled UNIT If lights are included plug the cord into the C 25 outlet labeled LIGHT Now you are ready to plug the C 25 NOTE Pattern sizes listed are approximate Variations in voltage caused by regional electrical differences or voltage drop due to long ...

Page 13: ...the connected equipment only Unplug timer before servic ing the unit or the equipment it controls THE MANUAL OVERRIDE KNOB IS NOT TO BE USED AS A POWER DISCONNECT For maximum protection against electri cal shock hazard perform test procedure on G F C I at least once a month Mount at least 5 ft from open water G F C I TEST PROCEDURE The G F C I should be checked every month to make sure that it is ...

Page 14: ...h the winter However when the water is thrust into the air it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32O F It is not necessary to store Kasco motors upside down All internal seals are fully lubricated while stored in an upright position CLEANING Fountains...

Page 15: ...nty claim Any expedited shipping method for the return of the unit is at the customer s expense Kasco Marine will return units repaired under warranty at our expense via ground freight within the continental United States Warranty Policy Warranty Period Model 2400SF 1 years Kasco Marine Inc warrants this Fountain to be free from defects in material or workmanship except for the ropes power cord an...

Page 16: ...s not getting the proper voltage This could also indicate a problem with the motor of the unit which needs to be looked at by an Authorized Repair Center Check that the unit is receiving the proper voltage and if so contact Kasco for further steps Other Repairs Most failed equipment can be repaired at substantially lower costs than replacement with new Please ship according to the instructions in ...

Page 17: ...he cause of the problem The problem could be one of many such as low water levels build up on the unit to prevent heat dissipation something inhibiting the free rotation of the shaft etc If something is caught in the unit or there is a build up of algae calcium or organic matter on the unit remove the debris and if caught early enough the unit should be fine Contact a Kasco representative before r...

Page 18: ...C ASSEMBLY 1 20 IN LBS 12 462237 1 2 20 waxed nut SS 1 13 361310 FLOW STRAIGHTENER 1 14 361320 NOZZLE 1 2 HP FOUNTAIN 1 15 361313 Oring 1 2 hp nozzle 1 16 840536 NUT 1 4 20 6 50 IN LBS 17 584692 1 4 20 X 1 3 8 BOLT 3 18 361543 8 flat washer 12 19 820405 SCREW 6x1 2 IN PH PHIL ULTRA SS 4 20 771033 Washer 8 split lock black oxide 6 21 475630 1 4 20 X 1 3 4 LONG BOLT 3 22 140312 RETAINING CLIP 3 23 3...

Page 19: ...clude the power cord and cage assembly fountain housing with each unit sent in for repair to be considered for warranty and for proper repair and shipping protection Do not ship the float and or control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address ____________________...

Page 20: ... 2400SF _______________________________ Serial Ex 2101S241025 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com 884361 ...

Reviews: