background image

16

“My Fountain flow seems to fluctuate and/or be less 

than usual.” 

   

If the nozzle is being used, make sure the 

flow straightener is tightened securely to the fountain 

housing.  A gap between the flow straightener and 

housing will result in a loss of pressure and the 

performance will be reduced.  Also check to see 

if the oring is installed correctly between the flow 

straightener and nozzle.  

    

This symptom is also caused from unit being 

clogged with debris.  A mat of weeds, many leaves, 

plastic bags, etc. can clog up the unit and cause it to be 

starved of water.  If the unit does not have the proper 

amount of water, the flow or pattern will fluctuate up 

and down and look sporadic.  If you are seeing these 

symptoms, unplug the unit and clean away the debris 

that is clogging up the screen either screen.  Another 

possibility if these symptoms are noticed, is a chipped 

or damaged prop that is causing the unit to wobble and 

not pump properly.  When the unit is unplugged, check 

the prop for damages and replace if damage is found. 

“My Fountain trips the ground fault interrupter in the 

C-25.”

 

This is the most common symptom of several 

possible problems.  To correctly diagnose the problem,  

you will need to collect more information.  A Ground 

Fault Interrupter (GFI) breaker that trips can in- 

dicate an electrical service problem, water contamina-

tion in the unit and/or cord, bad breaker, control  

box problems, motor problems, etc.  Try to find out the 

answers to these questions before you contact  

Kasco to narrow down the problem.  

•  How long does it take to trip the breaker?  

•  Does it always take the same amount of time to 

trip?

•  How many times has it tripped?

•  Has there been any electrical problems in the area 

recently?

“My Fountain seems to run slowly.”

 

This can also be a symptom of several possible 

problems.  There could be an electrical problem where 

the unit is not getting the proper voltage.  This could 

also indicate a problem with the motor of the unit, 

which needs to be looked at by an Authorized Repair 

Center.  Check that the unit is receiving the   proper 

voltage, and, if so, contact Kasco for further steps.

Other Repairs:

Most failed equipment can be repaired at substantially 

lower costs than replacement with new.  Please ship 

according to the instructions in the previous section.  

Again, it is best to call ahead for a Return Authori-

zation Number and/or Repair Form so we know the 

repair is coming.

Kasco Marine does estimates on repairs at the request 

of the customer.  The request for estimate should be 

included in the letter that accompanies the returned 

unit and must include a daytime phone number and/or 

e-mail address.  Estimate options are as follows:

We will contact the customer with a total after the unit 

has been evaluated, but before the work is performed.

We will repair the unit only if repair costs are under a 

stated dollar amount.  Example: “Please repair if total 

is under $150.00 before shipping charges.”

All estimates that are rejected for repair will be de-

stroyed unless otherwise directed by the customer.  If 

the customer would like the unit returned, the unit will 

be restored as closely as possible to the condition in 

which it was received and shipped at the customer’s 

expense for shipping and handling charges.

Billing:

All non-warranty repairs will be returned to the cus-

tomer prepaid with Visa or Mastercard or shipped 

C.O.D. with C.O.D. charges unless otherwise directed.  

Kasco Marine will call for credit card information 

upon completion of the repair.

All other warranty and repair inquiries should be di-

rected to Kasco Marine, Inc. at 715-262-4488 or 
[email protected]

Troubleshooting Tips

Below are some helpful troubleshooting tips.  If a 

problem occurs, please double check the assembly and 

installation instructions as well as the instructions for 

the proper control panel.  More troubleshooting tips 

can be found at www.kascomarine.com (under the 

technical tab)

Summary of Contents for xStream 2400SF

Page 1: ...2 Control Panel Installation pg12 C 25 Timer Control Instructions pg13 Maintenance Recommendations pg14 Warranty Policy pg15 Troubleshooting Tips pg16 Replacement Parts pg18 Customer Repair Form pg19 Registration Information pg20 Rev 07 29 13 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 FAX 715 262 4487 www kascomarine com C Intertek 3020379 ANSI UL 778 5th Ed 2010 CAN CSA C22 2...

Page 2: ...ntrol Box 120V supplied by Kasco and that the C 25 is plugged into a properly grounded grounding type receptacle The GFCI breakers should be tested upon each installation and every month thereafter to ensure proper operation General Instructions INSPECT THE SHIPMENT Immediately inspect your Kasco Fountain shipment for any visible damages Also cross reference the parts supplied with the Parts Inclu...

Page 3: ...NIT and the C 25 plugged into a properly grounded receptacle See C 25 Instructions It is extremely important to test the GFI breaker in the control panel upon each installation and reinstallation and every month thereafter to ensure proper operation Kasco Fountains are lightweight energy efficient and easy to install and operate We strive to produce products that exceed customer expectations We ho...

Page 4: ...presentative immediately 2 Place float on motor housing The power cord notch on the float should line up with the cord See diagram below of bottom side of float The 3 bolt holes in the float should line up with bolt receptacles on unit power cord notch 3 Use one of the 1 4 20 x 3 1 4 Phillips Pan Head Screws one 1 4 split washer and a 1 4 Flat Washer to secure the float Make sure the split washer ...

Page 5: ...er two 1 4 flat washers and 1 4 nut Do not overtighten 1 4 flat washer 1 4 nut 1 4 lock washer 1 4 x 1 3 8 bolt Align this screen feature with this float feature 9 Flip the unit back over so that the stainless steel can is resting on a flat surface Use the Nylon Cable Tie included to secure the power cord to a molded hole in the float to prevent cord damage if there is no strain relief on the cord...

Page 6: ... chart and nozzle pictures to choose a pattern push plugs into the holes shown with black circles on the chart The number of possible patterns are not all shown on the following chart Nozzle Option Chart Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 1 6 18 2 4 5 18 3 6 5 18 5 Important Push in black plugs on the inside of the nozzle only Plugs on Inside ...

Page 7: ...7 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 4 5 18 5 5 6 5 18 5 6 5 18 5 7 7 17 8 5 5 17 9 7 21 ...

Page 8: ...8 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 10 5 5 21 11 7 21 12 4 5 21 13 7 21 14 5 5 21 15 7 5 20 ...

Page 9: ...9 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 16 6 20 17 7 5 23 18 5 5 23 19 8 21 20 5 5 21 21 8 13 ...

Page 10: ...10 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 22 6 5 13 23 8 25 24 4 25 25 8 25 26 6 5 25 27 8 5 13 ...

Page 11: ...11 Pattern Height ft Width ft Plug diagram black circles show plug locations Picture 28 6 5 13 29 8 5 22 30 5 22 31 8 5 24 32 4 24 33 8 5 24 ...

Page 12: ...electrical codes for this installation and Consult a qualified electrician or service person if needed Plug the aerator cord into the C 25 outlet labeled UNIT If lights are included plug the cord into the C 25 outlet labeled LIGHT Now you are ready to plug the C 25 NOTE Pattern sizes listed are approximate Variations in voltage caused by regional electrical differences or voltage drop due to long ...

Page 13: ...the connected equipment only Unplug timer before servic ing the unit or the equipment it controls THE MANUAL OVERRIDE KNOB IS NOT TO BE USED AS A POWER DISCONNECT For maximum protection against electri cal shock hazard perform test procedure on G F C I at least once a month Mount at least 5 ft from open water G F C I TEST PROCEDURE The G F C I should be checked every month to make sure that it is ...

Page 14: ...h the winter However when the water is thrust into the air it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32O F It is not necessary to store Kasco motors upside down All internal seals are fully lubricated while stored in an upright position CLEANING Fountains...

Page 15: ...nty claim Any expedited shipping method for the return of the unit is at the customer s expense Kasco Marine will return units repaired under warranty at our expense via ground freight within the continental United States Warranty Policy Warranty Period Model 2400SF 1 years Kasco Marine Inc warrants this Fountain to be free from defects in material or workmanship except for the ropes power cord an...

Page 16: ...s not getting the proper voltage This could also indicate a problem with the motor of the unit which needs to be looked at by an Authorized Repair Center Check that the unit is receiving the proper voltage and if so contact Kasco for further steps Other Repairs Most failed equipment can be repaired at substantially lower costs than replacement with new Please ship according to the instructions in ...

Page 17: ...he cause of the problem The problem could be one of many such as low water levels build up on the unit to prevent heat dissipation something inhibiting the free rotation of the shaft etc If something is caught in the unit or there is a build up of algae calcium or organic matter on the unit remove the debris and if caught early enough the unit should be fine Contact a Kasco representative before r...

Page 18: ...C ASSEMBLY 1 20 IN LBS 12 462237 1 2 20 waxed nut SS 1 13 361310 FLOW STRAIGHTENER 1 14 361320 NOZZLE 1 2 HP FOUNTAIN 1 15 361313 Oring 1 2 hp nozzle 1 16 840536 NUT 1 4 20 6 50 IN LBS 17 584692 1 4 20 X 1 3 8 BOLT 3 18 361543 8 flat washer 12 19 820405 SCREW 6x1 2 IN PH PHIL ULTRA SS 4 20 771033 Washer 8 split lock black oxide 6 21 475630 1 4 20 X 1 3 4 LONG BOLT 3 22 140312 RETAINING CLIP 3 23 3...

Page 19: ...clude the power cord and cage assembly fountain housing with each unit sent in for repair to be considered for warranty and for proper repair and shipping protection Do not ship the float and or control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address ____________________...

Page 20: ... 2400SF _______________________________ Serial Ex 2101S241025 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com 884361 ...

Reviews: