background image

LEDC11 MANUAL

2

SAFETY FIRST

Please read and follow these important instructions to help ensure your safety and the quality performance 

of your Kasco equipment.

• 

LEDC11 kit is 120Vac and MUST be plugged into a GFCI protected receptacle or GFCI protected field 

terminal connections.

• 

LEDC11 fixtures MUST be properly submerged (approximately halfway) to avoid overheating; insufficient 

submersion or operation out of water will damage fixtures and void warranty.

•  Use caution when dealing with any electrical and/or moving equipment.

•  Under NO CIRCUMSTANCES should anyone enter the water with the electrical equipment plugged in 

and/or in operation.

•  Kasco WaterGlow lighting kits are intended for use with a Listed control panel having a GFCI protected 

receptacle, or field wiring terminals and disconnect switch, or a timer with a disconnect for use with a 

GFCI receptacle. They are intended to be mounted on a floating fountain or aerator for use in a natural 

or man-made body of water to comply with NEC Article 682.

•  Kasco WaterGlow lighting kits have not been evaluated for use in swimming pools, spas or stationary 

fountains.

• 

Use extreme caution around water, especially cold water, as in spring, fall, and winter, which poses a 

hazard in and of itself.

•  NEVER lift or drag the equipment by the power cords. If you need to pull the unit to the side of the pond, 

use the anchoring ropes.

•  Do not use boats that tip easily for lighting kit installation and follow all boating safety rules and regu-

lations, including wearing a PFD (Personal Flotation Device). Do not use waders in deep ponds/lakes or 

ponds/lakes with drop-offs, drastic slopes, or soft bottom material.

•  For more information regarding your control panel instructions, refer to your equipment owner’s manu-

al. A control panel must be installed a minimum of 5 feet (3m in Canada) from the body of water unless 

separated from the body of water by a fence, wall, or other permanent barrier that will make the unit 

inaccessible to persons in the water. A complete list of control panels can be found in the Accessories 

section of 

kascomarine.com

.

Back to Contents

Summary of Contents for WaterGlow LEDC11

Page 1: ...ere Rd Prescott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 LEDC11 Operation Maintenance Manual Document number 884012 Document version 2021 2 0 Composi...

Page 2: ...scomarine com TABLE OF CONTENTS QUESTIONS Safety First 2 Parts Included 3 Mounting Instructions 4 Alternate Mounting Instructions 7 Maintenance Recommendations 8 Troubleshooting Tips 8 Warranty 10 Rep...

Page 3: ...ural or man made body of water to comply with NEC Article 682 Kasco WaterGlow lighting kits have not been evaluated for use in swimming pools spas or stationary fountains Use extreme caution around wa...

Page 4: ...345035 E 10 32 thumb nut 6 345043 F 10 split lock washer 6 771037 G Bracket O ring 6 345008 H Bracket clip 3 345007 I 10 32 x 1 2 hex screw 6 345042 J Snap on light clip 3 361445 K 1 4 20 x 1 3 8 hex...

Page 5: ...e bracket Tighten the thumb screws on each side hand tight only Repeat this step for all fixtures 2 Optional If you want to use one of the color choices instead of the standard soft white light peel t...

Page 6: ...ture housing as shown Make sure the fixture and lens are clean before installing the lens cap Repeat for all fixtures 4 Slide bracket into the top flange on the snap on clip J until it clicks into pla...

Page 7: ...ired being sure to use the same angle for all fixtures Cable ties can be used to attach fixture cords to float to decrease play and ensure protection Cable tie O light kit power cord to float opposite...

Page 8: ...the snap on light clip following the directions above and continuing to step 6 on page 6 For Large Surface Aerator units Supplementary hardware is required in order to mount RGBC5 light fixtures to a...

Page 9: ...m the expansion pressure of ice Storage over winter is best in a location that is out of the sun and cool but above 32 F Cleaning Light kits should be removed from the water at least once per year at...

Page 10: ...r to the outlet C 85 or C 95 control panel with terminal connections and timer control for light kit For panels with a GFCB ground fault circuit breaker and timer controlled lights simply reset the tw...

Page 11: ...al receipt and registering the equipment online at kascomarine com under the Warranty Information section Once warranty coverage has been established the light kit may be sent to Kasco or any Kasco Au...

Page 12: ...e work is performed All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer Rejected equipment can be returned at the customer s expense for shipping and...

Page 13: ...hemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be acco...

Reviews: