ALTERNATE INSTALLATION

In ponds where the water level fluctuates significantly, 

you may need to suspend a small weight (12” of 1” 

galvanize pipe works well) at the mid-point of the 

rope to take up any slack as the water level drops.  The 

weight should be light enough so the Fountain can rise 

as the water level rises.  This can also help hide ropes 

by sinking them further below the surface.

 

  

Maintenance Recommendations

** Under No Circumstances should anyone enter the 

water while a fountain is operating. **

** Please keep the original box for maintenance ship-

ping. **

The following maintenance procedures can be utilized 

to ensure many years of quality performance from 

your Kasco Fountain and reduce the need for more 

costly repair work.

PROPER INSTALLATION:  Proper installation of 

Kasco equipment will include a power source with 

ground fault interruption (GFI).  For Fountain models, 

the C-25 control (120V) or C-85 (240/208V) included 

with the unit have built-in ground fault interrup-

tion that is sufficient.  Ground fault interrupters are 

a safety feature that can also alert you to electrical 

leaks in the equipment.  It is extremely important to 

test the GFI upon installation, each reinstallation, and 

monthly thereafter to ensure proper operation.  If you 

have repeat, consistent trips on your ground fault, the 

equipment should be disconnected and removed from 

the water.  The power cord should be inspected for 

damage and you should call Kasco Marine at 715-262-

4488 for further instructions or email Kasco at  

[email protected].

OBSERVATION:  Operating equipment should be 

observed on a regular basis (daily, if possible) for any 

reduction or variation in performance.  If a change 

in performance is observed, the equipment should be 

disconnected from power and inspected for any ma-

terial that may have clogged the system or wrapped 

around the shaft of the motor, especially plastic bags 

and fishing line.  Even though Kasco Aerators and 

Fountains are among the most clog-resistant on the 

market, it is impossible to protect against all items that 

can clog equipment and still maintain a flow of water.  

These materials can be very damaging to the equip

-

ment under continued operation and must be removed 

as soon as possible.  ALWAYS UNPLUG THE UNIT 

BEFORE ATTEMPTING TO REMOVE CLOGS.

WINTER STORAGE:  In regions where there is 

significant freezing in the wintertime, the fountains 

should be removed from the water to protect them 

from the expansion pressure of the ice.  In many areas, 

Summary of Contents for J Series

Page 1: ...ntain 3400JF 3400HJF 4400JF 4400HJF Rev 03 2019 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 FAX 715 262 4487 www kascomarine com C Intertek 3020379 ANSI UL 778 2016 Ed 6 R 22Feb201...

Page 2: ...rts Included pg4 Tools Supplies Needed pg5 Assembly Instructions pg6 Nozzle Options pg8 Installation Instructions pg8 Maintenance Recommendations pg9 Warranty Policy pg10 Billing pg11 Troubleshooting...

Page 3: ...lubrication is needed Make sure to keep the motor housing clean THANKS We at Kasco Marine Inc would like to both thank and congratulate you on your purchase of the JF model aerating fountain We apprec...

Page 4: ...It is extremely important that proper and sufficient voltage 120V or 240 208V is supplied to the Foun tain motor Each 120V Fountain is supplied with a UL and CSA approved C 25 GFI Protected Control B...

Page 5: ...E PROJECTION TITLE XXXX XXXX XX SHEET 1 OF 1 FINISH MATERIAL SCALE 1 20 Set of Interchangeable Nozzles 4 Item Part Qty 1 Sequoia Nozzle 431230 1 2 Linden Nozzle assembly 431232 1 3 Birch Nozzle 431234...

Page 6: ...G 800 DEERE ROAD PRESCOTT WI 54021 1241 X 3400J SERVICE PRINT X NONE X AS NOTED ABOVE THIS DRAWING CONTAINS PROPRIETARY INFORMATION AND SHALL NOT BE USED REPRODUCED OR DISTRIBUTED WITHOUT THE PRIOR WR...

Page 7: ...ARE MILLIMETERS TOLERANCES ON THIS DOCUMENT HAS BEEN ISSUED FOR ENGINEERING INFORMATIONAL PURPOSES ONLY ANY REVISIONS TO THE CONTENT OF THIS DOCUMENT MUST BE INCORPORATED INTO THE ORIGINAL CAD FILE TH...

Page 8: ...OF KASCO MARINE INCORPORATED X 02 508 XX 010 254 XXX 005 127 ANGULAR 0 5 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES DIMENSIONS IN ARE MILLIMETERS TOLERANCES ON THIS DOCUMENT HAS BEEN ISSUED F...

Page 9: ...o test the GFI upon installation each reinstallation and monthly thereafter to ensure proper operation If you have repeat consistent trips on your ground fault the equipment should be disconnected and...

Page 10: ...void the warranty This includes tampering with the unit power cord and or control box Please contact Kasco Marine Inc at 715 262 4488 for your nearest Authorized Repair Center ZINC ANODE A Sacrificial...

Page 11: ...Kasco Marine Inc at 715 262 4488 or sales kascomarine com the serial number scheme below Sample Serial 70 01 VX 2 1725 The first two digits represent the reverse of the last two digits of the year of...

Page 12: ...ent and any base voltage differences This problem can also be caused by a bad breaker or receptacle or having unbalanced incoming voltage lines Troubleshooting Tips Below are some helpful troubleshoot...

Page 13: ...13...

Page 14: ...14 3400J Replacement Parts 884180...

Reviews: