Kasco J Series Owner'S Manual Download Page 1

Owners Manual

J Series Fountain

3400JF & 3400HJF

4400JF & 4400HJF

 Rev. 03/2019

Kasco Marine, Inc.

800 Deere Rd.

Prescott, WI 54021

PH (715) 262-4488  

FAX (715) 262-4487

www.kascomarine.com

C

Intertek

3020379

ANSI/UL 778: 2016

Ed.6+R:22Feb2017

CSA C22.2 #108: 2014 Ed.5

Summary of Contents for J Series

Page 1: ...ntain 3400JF 3400HJF 4400JF 4400HJF Rev 03 2019 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 FAX 715 262 4487 www kascomarine com C Intertek 3020379 ANSI UL 778 2016 Ed 6 R 22Feb201...

Page 2: ...rts Included pg4 Tools Supplies Needed pg5 Assembly Instructions pg6 Nozzle Options pg8 Installation Instructions pg8 Maintenance Recommendations pg9 Warranty Policy pg10 Billing pg11 Troubleshooting...

Page 3: ...lubrication is needed Make sure to keep the motor housing clean THANKS We at Kasco Marine Inc would like to both thank and congratulate you on your purchase of the JF model aerating fountain We apprec...

Page 4: ...It is extremely important that proper and sufficient voltage 120V or 240 208V is supplied to the Foun tain motor Each 120V Fountain is supplied with a UL and CSA approved C 25 GFI Protected Control B...

Page 5: ...E PROJECTION TITLE XXXX XXXX XX SHEET 1 OF 1 FINISH MATERIAL SCALE 1 20 Set of Interchangeable Nozzles 4 Item Part Qty 1 Sequoia Nozzle 431230 1 2 Linden Nozzle assembly 431232 1 3 Birch Nozzle 431234...

Page 6: ...G 800 DEERE ROAD PRESCOTT WI 54021 1241 X 3400J SERVICE PRINT X NONE X AS NOTED ABOVE THIS DRAWING CONTAINS PROPRIETARY INFORMATION AND SHALL NOT BE USED REPRODUCED OR DISTRIBUTED WITHOUT THE PRIOR WR...

Page 7: ...ARE MILLIMETERS TOLERANCES ON THIS DOCUMENT HAS BEEN ISSUED FOR ENGINEERING INFORMATIONAL PURPOSES ONLY ANY REVISIONS TO THE CONTENT OF THIS DOCUMENT MUST BE INCORPORATED INTO THE ORIGINAL CAD FILE TH...

Page 8: ...OF KASCO MARINE INCORPORATED X 02 508 XX 010 254 XXX 005 127 ANGULAR 0 5 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES DIMENSIONS IN ARE MILLIMETERS TOLERANCES ON THIS DOCUMENT HAS BEEN ISSUED F...

Page 9: ...o test the GFI upon installation each reinstallation and monthly thereafter to ensure proper operation If you have repeat consistent trips on your ground fault the equipment should be disconnected and...

Page 10: ...void the warranty This includes tampering with the unit power cord and or control box Please contact Kasco Marine Inc at 715 262 4488 for your nearest Authorized Repair Center ZINC ANODE A Sacrificial...

Page 11: ...Kasco Marine Inc at 715 262 4488 or sales kascomarine com the serial number scheme below Sample Serial 70 01 VX 2 1725 The first two digits represent the reverse of the last two digits of the year of...

Page 12: ...ent and any base voltage differences This problem can also be caused by a bad breaker or receptacle or having unbalanced incoming voltage lines Troubleshooting Tips Below are some helpful troubleshoot...

Page 13: ...13...

Page 14: ...14 3400J Replacement Parts 884180...

Reviews: